CW-HPC600A Handheld Laser Particle Counter 6-Channels Dust Analyzer Auto Printer

 

Description:

CW-HPC600(A) handheld optical particle counter utilizes the laser technology for single particle detection. The scattering of light from the particles in the sampling air steam is converted into electrical pulses, which is then measured and calculated as a  particle size. 

The HPC600(A) consists of a handheld set with a main base unit that  allows users to conduct the sampling around with a handheld set while easily expanding  to multiple functionalities with a base unit. These extended functions include data  downloading, data real-time printing, software upgrading, and battery charging, etc. 

The HPC600(A) Particle count data is displayed as Concentration mode (Counts/Liter).  

The HPC600(A) can also include a digital temperature and relative humidity probe, backlit interface and is capable of storing 1000 sample records. It is in compliance with the international standards (JIS B 9925:1997 and ISO14644-1) and support both metric and English systems.


Features:
• User configurable for all six size channels
• Auto print function
• Set and display date and time
• High speed USB interface for data downloading 
• Up to 1000 sets of data can be stored
• Timer, auto-start sampling 
• Average of multiple times of measurements
• External digital temperature and humility sensors to assure accurate measurement
• Support both English and Chinese languages display
• No less than 6 hours of continuous operation
• Count Limit Warning: Setting according to the FED standard 209E or ISO 14644-1 standard
• Error status indicator: The instrument will automatically monitor the sensor status, out of flow calibration (>±5%), or insufficient battery


Specification:

• Test Range: 0.3μm~25μm

• Channel: 6-channels

• Flow rate: 0.6L

• Light Source: Laser diode (more than 100,000 hours MTBF)

• Coincidence Loss: <5% 70,000 particles/Liter

• Counting Efficiency: 50±5% 0.3μm; 100±10% 0.5μm

• Test Standard: JIS-B-9921 (1997), ASTM-F649-01, ASTM-F328-98 (NIST traceable)

• Sampling Time: 1 sec ~ 59 min and 59sec (User defined)

• Sampling Count: 1 ~ 99 (User defined)

• Count Limit Warning: FED STD 209E (Class 1 ~ 100,000) or ISO 14644-1 (Class 2 ~9)

• Measurement: Single/repeat/Average

• Error Indication: Count limit, loss of laser power, out of flow calibration (>±5%),insufficient battery

•Interface: USB, RJ45, RS232

• Communication Speed: USB —12Mbps

• Power: Li-ion polymer rechargeable battery (7.4V/2800mAH) or AC adapter (AC input:100 ~ 240V, DC output: 9V/1.5A)

• Max. Operating time: continue operation > 6 hours with Li-ion polymer battery)

• Operating temperature: 5~ 45℃; <90%RH

• Dimension: 93 (W) ×185 (H) × 48 (D) mm

• Weight: about 1kg

• Storage temperature: -20~ 60℃; <90%RH

• Standard configuration: AC adapter, Drive disc (enclosed specification), Portable protection case, Isokinetic sampling head

• Optional parts: Temperature and humidity sensor


What's in Package:

1x CW-HPC600A Laser Particle Counter 


1.Your valid phone number is  very necessary for the shipping, otherwise we can't guarantee that  the package would safely arrives.
2. Any Customs tax applied to this package should be covered by  buyers.

 

Contact Us:
1. We have always been trying to provide the best service and reliable products  for every customer, however, accident may happen sometimes, please contact us to  resolve any issue before leaving a negative feedback.
2. Please contact us by "Ask a question".

 

Payment
1. Payment methods  accepted : Paypal  only.
2. Payment must be  received within 7  business days of  auction closing.

 

Shipping

1. We ship your  orders within 1-2  business days after  the payment  received.

2. Item shipped via  Singapore Post or  HongKong Post , It  takes about 7-14  business days (USA,CA,AU,UK). others  country 10-20  business  days(Brzil,India,RU), Exact  delivery time  depends on postal  process.

3. If you do not  receive your item(s)  by 30 business  days, Please feel  free to contact us  via ebay mail system  , we will try our  very best to resolve  any problems with  you 

 

Return Policy

1. Return is  accepted within 14  days after the  buyer's receiving  the item.

2. If this item is  defective upon  receipt, customer  has up to 14 days  from date of receipt  for exchange of a  new one.

3. Unused/unopened  merchandise will be  fully credited.

 

Other Policies

 

We are not  responsible for any  custom duty or  import tax.

 

Any customs duty applied to the parcel  should be covered by the buyer.

As has been stated on the eBay item description, Import duties, taxes and  charges are not included in the item price and shipping charges.
These charges be at the buyer responsibility. meanwhile the customs tax depend  on the buyer local customs office.

 

If you need we write  low price on  shipping bill, pls  leave message when  you make payment .

 

All emails will be  answered within 24  hours. If you do not  receive our reply,  please kindly  re-sent your email  and we will reply to  you as soon as  possible, Suggest  send eBay message to  us, That is easy to  find .