Implant Fixture & Fractured Screw Removal Kit NeoBiotech SR MCTBIO FSRK-02


Shipping Directly From Walnut, California, 91789, United States


Item Descriptions
 
 MCTBIO Fixture & Screw Removal Master Kit  FSRK-02
 
The implant fixture and fractured screw removal kit is the only kit you need to remove failed dental implants and fractured screws. 
Our new Next Generation Kit features 7 extra parts at the same unbeatable price! Watch videos below.
Remove a fractured/broken screw and save the implant, or
Remove a failed implant while minimizing trauma to the bone.

This kit include the following items
  • Fixture removal drills FRD-01 (mini), FRD-02 (regular), FRD-03 (Wide), Adapter 1
  • Screw removal guide 3i Internal NP, 3i Internal RP, External mini, External Regular, ITI Octa, Nobel Replace Tri-Lobe RP, Nobel Replace Tri-Lobe WP, Nobel Replace Tri-Lobe NP, Zimmer TSV 3.7/4.7, Zimmer TSV 5.7, Astra Hex, Noble Active NP, Noble Active RP, FRW-01 Wrench
  • Screw Removal Drill & Tap SRD-01, SRT-01, SRT-02 (Wide), SRA-01(Adapter)
  • Fixture Removal Trephine Bur FRT-3.7/4.4 (Ø3.5), FRT-3.9/4.6 (Ø3.7), FRT-4.3/5.0(Ø4.1), FRT-4.7/5.4 (Ø4.5), FRT-5.2/5.9 (Ø5.0), FRT-5.7/6.4 (Ø5.5), FRT-6.2/6.9 (Ø6.0), SRG-H, Adapter H
PY Fixture & Screw Removal Kit

The usage of the SOS implant remover kit is easy and convenient just insert a remover tip into the implant until it is tight then make use of the hand adaptor or remover wrench to extract the implant from the socket.
 
Capable of removal and replacement of implants in ill-positioned placement cases. It helps to remove broken screws without damaging the implant. A perfect solution with the best results. All is done with minimal trauma to the patient and without any surgical interference.
  • Both Osseo integrated implants and fractured implants are simply removed.
  • No bone damage or trauma to patients.
  • No need to use a trephine drill.
  • Applicable to any type of implant with a screw hole.
  • Capable to remove and replace the implant in an ill-positioned implant placement case.
  • Helps to remove broken screws without damaging the implant.
  • Fit virtually any implant system external hex, internal hex, conical connection, and more.
  • Removes failed implants without compromising surrounding bone or damaging neighboring structures.
Screw Remove Drill
  • This is the tool to take out the broken screw by turning in reverse way.
Screw Remove Tap
  • This is the tool to take out the broken screw by turning in reverse way.
Screw Remove Bar
  • This tool is for taking out broken screw through picking up.
Screw Remove Guide
  • Instruments to guarantee the screw remove drill can be stable working in the center of broken screw.
Fixture Remove
  • To take out useless fixture by bone loss or broken, use this by locking in reverse way.
Cover Screw Remove
  • This is the tool after making the hole like slot shape and turn in reverse way to take out.
Ratchet Wrench
  • Use this attaching with the fixture remove and the cover screw remove for when you put your fingers to screw.
Kit Include
  • screw remove drill
  • screw remove tap
  • screw remove bar
  • screw remove guide sub non-hex 22N
  • screw remove guide sub non-hex 16N
  • screw remove guide sub. hex 2.5
  • screw remove guide sub. hex 2.1
  • fixute remove f 22°
  • fixure remove 16°
  • fixure remove 16° N
  • cover screw remove
  • ratcher wrench

 
GSM Screw Removal Kit
 

1. Claw

This is a surgical tool that removes a screw that has become fractured inside the Fixture.
After selecting the size that is appropriate for the size of the screw that is to be removed, it must be used by connecting a guide to the Fixture (Conical/Internal/External Guide). Then it is connected to the Shank Driver, and the fractured screw can be removed by rotating by hand in the reverse direction. If the fractured screw cannot be removed using the Claw, it must be removed using the Reverse Drill and the Screw Remover.

 

 Product Name

Fractured Screw size 

Product Name 

Fractured Screw size 

CD16

 M1.6

 CD20

 M2.0

CD18

 M1.8

 CD25

 M2.5

2. Reverse Drill

 - This is a tool that creates a hole on the fractured face of the Screw that will be used by the Screw Remover.
 - After selecting the appropriate Reverse Drill for the size of the screw that needs to be removed, it must be used by connecting a guide for the fi xture (Perfect/ Conical/Internal/External Guide). The depth of the drill can be adjusted from 1 mm to 3 mm, because the Drill body has markings.

 - The removal of an M1.6 size Screw Should utilize the Claw.
 - Although diff erent manufacturers produce diff erent sizes of abutment screws, except in rare cases, typically they utilize screws of Size M1.6, M1.8, M2.0, or M2.5. (‘M’ stands for a metric screw. The number indicates the external size of the screw. For example, “M1.6 Screw” indicates that it is a metric screw the external diameter of  Which is 1.6 mm). 

  

 Product Name

 Diameter(Ø)

 Fractured Screw size

 RCD10

 Ø 1.0

 M1.8

 RCD12

 Ø 1.2

 M1.8

 RCD14

 Ø 1.4

 M1.8

3. Screw Remover

 - This is a device that removes a fractured screw. Insert a Screw Remover that is appropriate for the size of the hole that has been formed using the Reverse Drill and rotate at a low speed (at or below 80 rpm) in the reverse direction.
 - The Screw Remover was designed in a tapered shape so as to increase, as it turns, the amount of friction, which is necessary to loosen the Screw.

 

 Product Name

Diameter (Ø)

Fractured Screw size 

 SR10

 Ø 1.0

 M1.8

 SR12

 Ø 1.2

 M2.0

 SR14

 Ø 1.4

 M2.5

 

4. Shank Driver

 - This is a surgical tool that was designed to be connected to the Screw Remover to allow the use of the hand, Torque Wrench, or Ratchet. 

 

 Product Name

Standard 

Applicable Products 

 SHD00

 for Hand or Ratchet

 Screw Remover

(SR10, SR12, SR14)


5. Perfect Guide & PG Hand Driver

 - The Perfect Guide acts as a Guide for the Reverse Drill. It is used when the screw is fractured at the lower part of the female screw inside the Fixture. It is connected to PG Hand Driver and is directly applied to the Fixture female Screw.

 - The Perfect Guide can be safely used because it has a stop structure inside that prevents the Reverse Drill from drilling more than 2 mm.


6. Conical, Internal, External Guide

 

 - They act as the Guide when using the Reverse Drill. They are used when the Perfect Guide cannot be used, or if the screw was fractured at a location deeper than 2 mm into the lower part of the female screw inside the Fixture.
 - The Guide appropriate for connecting to the Fixture must be selected.
 

7. SR Driver Holder

 

This can be easily affixed to the Fixture by connecting it to the 3.5 Double Hex part of the Conical, Internal, or External Guide.



FDA Statement:

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.