Description:
1.The use of a direct-acting diaphragm structure without pressure starts expands its field of use
2.The flat diaphragm structure is reliable in opening and closing, and the service life of the product is enhanced
3.The valve is N / C (normally closed), meaning it will shut down when not powered
4.The valve body made of brass has excellent anti-pressure explosion-proof and corrosion resistance, fast heat dissipation, stable operation and no noise
5.Copper core coil component is sufficient, work response is fast, not easy to heat
6.When installing the solenoid valve, the solenoid valve mark on the valve body should be consistent with the flow of the pipeline fluid
7.This brass solenoid valve has a wide range of applications and is easy to replace broken valves for water, air and other low viscosity fluids

Specification:
Body material: Brass
Type: Normally closed
Operatiing: direct acting
CV value: 4.8
Thread size: 1/2"PT
Voltage: AC110V
Wire Long: 150mm/5.9"
Operating voltage range: ±10%
Mode of action: Direct motion
Working medium: air, water, oil
Working temperature: -5~80 degrees Celsius
Use fluid viscosity: below 20CST
Use pressure: 0~1Mpa
Maximum pressure resistance: 1.0Mpa
Total Size: 102x78x54mm/4.02"x3.07"x2.13" (LxWxH)
Normally closed type: power on, always off when not energized
Wiring method: two wires are connected
Installation method: the bottom indicates the direction of water flow, which in turn will affect the use.

Install and use Attentions:

  1.When install the solenoid valve, Medium flow direction must be consistent with the direction arrow as shown in the valve body,the valve must be installed in horizontal pipe runs.Solenoid valve coil keep in a vertical position,this valve can not be put in these places what with the splashing water or water leakage.The 2A model can be used in the underwater environment.

    2.Before installing the solenoid valve,pipeline should be cleaned thoroughly,the medium what crossing into the pipeline must be clean,viscosity<4°E.

  3.Front the valve should be installed the 80-100 mesh /filter prevent the valve core be jammed,when the pressure be larger where after the valve,should be install the one-way valve.prevent the medium backflow or cause the solenoid valve closed lax.

  4.In using should be regular cleaning dirt on the surface of the movable iron core and the piston,in dismounting should check the sealing gasket at the same time,when found damaged should be replaced timely.

  5. This valve is unfavorable use in the explosive dangerous places.When need, please indicate in ordering.

  6.Should be install the by-pass device,to ensure the normal production, for the solenoid valve needs change when the failure happens or need cleaning(as picture following)   

  7.According to the range of values from the scutcheon for choose power supply conditions and control its relay,place the down-lead of solenoid valve in the circuit,when Installing system,no grounding solenoid valve should be grounded,in order to ensure the safety.


Package Included: 1x Solenoid Valve

Note: The solenoid valve coil must be in an upright position and the valve must not be installed in a place where there is water splash or water leakage.