Main Features:

² Suitable for Increment Ration Packing Scale with optional Single-hopper-weighing Mode, Single-bag-weighing Mode, Double-hopper-weighing with one bag-clamping Mode, Double-hopper-weighing with two bag-clampings Mode and Double-bag-weighing Mode.

² EMC design with high anti-jamming capability, suitable for industrial environment.

² Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.

² 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.

² Loadcell Interface

2 Loadcell ports. Max. Connection Quantity: 2×8 Loadcells (350Ω).

24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.

Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.

² I/O Interface

9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].

Optional ‘High/Medium/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.

2 Definable analog signal AO[0~10V] for weight signal output or High/Medium/Low Speed Feed control.

² Digital Communication Interface

COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.

COM[RS232] for connecting RS232 Serial Printer.

USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.

² Software Function

Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.

Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.

Load Calibration and Loss Calibration functions available.

10 Recipes for packing control.

Optional Fall Value Auto Correction function.

Optional Auto Pause for Deviation Alarm and Auto Re-feed functions.

Optional ‘Target Batch Control’ function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].

The Batch Records can be printed automatically.

Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.

With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.