Product Parameters:
Product model: ZFX-W2062C
Product Name: Intelligent high precision digital humidity controller
Control humidity range: 1%RH-99%RH
Load power: 10A/DC12V
Humidity measurement range: 1% RH-999% RH measurement error:
±3% RH (good environment temperature is 25°C)
Control humidity accuracy: 1% RH display: 1% RH
Humidity return: adjustable between 1-50% RH
Supply voltage: DC12V
Output type: 10A relay output
Probe type: humidity resistance sensor
Size: 48*29*22mm (long * section * high)
Installation hole: 46*27m
Moisture control object: dehumidification or humidification
Probe line length: 1.5m line length
Working environment: humidity 90% RH no frosting
Parameter Code and Settings:
Code | Description | range | Factory settings |
P0 | Humidification/dehumidification | H/C | C |
P1 | Backlash | 1-50%RH | 95 |
P2 | Set the maximum limit | 99 | 5 |
P3 | Set the minimum limit | 1 | 10 |
P4 | Temperature correction | -10 | 1 |
P5 | Delayed start | 0-10 | OFF |
Setting Instructions:Connect the power supply and load to power the controller. The red color above shows the humidity, blue below.Also red is displayed as the desired humidity, and press STG (+) ENT (-) to set the required humidityAfter the setting is completed, wait for 3 seconds to automatically confirm the return. At this time, the controller automatically performs relay energization according to the setting.For 10A relays, to meet high power loads, please make sure the line is correct.Indicator light, digital tube status descriptionIndicator light: off means the relay is off, steady light means the relay is closedDigital tube: The above shows that LL is the sensor open circuit, indicating that HH is out of the measurement range, the humidity will forcibly open the relay.Display - for ultra high humidity protection.Parameter Function Description:Press and hold SET for 5 seconds to enter the main menu settings, press SET (+) ENT (-) to switch P0-P8, when adjusting parameters P0-P8 parametersIf you need to adjust P0, press SET button (+) ENT (-) at the same time, adjust 0K, then control SET (+) ENT (-)Once confirmed, P1-P8 and P0 set the parameters in each code according to their own needs.Panel Settings:
Wiring Diagram:
Package Included: 1 x DC12V 10A Red+Blue W2062C Digital Hygrometer Humidity Controller