624BLD ELECTRONIC BOARD (INCORPORATED INTO THE AUTOMATION)

Model: 624BLD
Mains supply voltage: 230V~ (+6%-10%) 50 (60) Hz
Max power: 7W
Max motor power: 300 W
Max accessories load: 500 mA
Accessory power supply voltage: 24V
Programming mode: 3 keys (+,-,F) and display
Operating logics: Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC-CITY, Man-present, Remote, Custom
Programmable functions: Logic, Pause Time, Force, Loop 1 and 2, Starting Torque, Pre-flashing, Slow Closing, Slow-down Time, Work Time, Lamp Output. indicator light, Fail-safe output, Status output, BUS output, Assistance request
Working time: Programmable (0 to 4 min)
Pause time: Programmable (0 to 4 min)
Motor force adjustment: Programmable on 50 levels
Terminal board inputs: Loop 1, Loop 2, Open, Close, Closing safety devices, Stop, Emergency, Power. 230V~ + Earth
Terminal block outputs: "Flasher, Fan, Motor, 24V Power Supply, Fail-Safe, Status Output, 24V Indicator Lamp
, BUS, 4 outputs programmable in 18 different functions"
Quick connector: 5pin MINIDEC card connection, DECODER, RP/RP2 receiver, Opening and closing limit switch, Motor capacitor, Bar release sensor
Integrated detector with 2 independent channels: Real time self-calibration, Sensitivity independent of the loop geometry, Adjustment of the loop working frequency, Loop busy message with LED display, Loop status addressable on the programmable outputs, Adjustment time adjustable on two levels.
Protection fuses: F1=F 5A-250V~ F2=T 0.8A-250V~
Operating ambient temperature: -20°C ÷ +55°C

Mod. 2022715

For 230V 620 Standard automatic barrier


24 month warranty





Operating logics: Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC-CITY, Man-present, Remote, Custom Programmable functions: Logic, Pause Time, Force, Loop 1 and 2, Starting Torque, Pre-flashing, Slow Closing, Slow-down Time, Work Time, Lamp Output. indicator light, Fail-safe output, Status output, BUS output, Assistance request Quick connector: 5pin MINIDEC card connection, DECODER, RP/RP2 receiver, Opening and closing limit switch, Motor capacitor, Bar release sensor Integrated detector with 2 independent channels: Real time self-calibration, Sensitivity independent of the loop geometry, Adjustment of the loop working frequency, Loop busy message with LED display, Loop status addressable on the programmable outputs, Adjustment t
Operating logics: Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC-CITY, Man-present, Remote, Custom Programmable functions: Logic, Pause Time, Force, Loop 1 and 2, Starting Torque, Pre-flashing, Slow Closing, Slow-down Time, Work Time, Lamp Output. indicator light, Fail-safe output, Status output, BUS output, Assistance request Quick connector: 5pin MINIDEC card connection, DECODER, RP/RP2 receiver, Opening and closing limit switch, Motor capacitor, Bar release sensor Integrated detector with 2 independent channels: Real time self-calibration, Sensitivity independent of the loop geometry, Adjustment of the loop working frequency, Loop busy message with LED display, Loop status addressable on the programmable outputs, Adjustment t