Features:
Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;
8 channels oscilloscope for vehicle testing;
Auto Ignition Probe;
2.4MSa/s real time sampling rate, 12bit vertical resolution;
spectrum analysis function;
10mV/div to 5V/div input sensitivity;
DAQ card function;
8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.
Specifications:
(1) Vehicle Testing
First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition
Ignition: primary and secondary
Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
Performer: Petrol/Diesel
Starter and charging circuits
(2) Oscilloscope
8 channels oscilloscope, 2.4MSa/s real time sampling rat
12 bits vertical resolution, spectrum analysis function
(3) Programmable Generator
8 channels programmable generator
Can analog signals of crankshaft, camshaft etc.
(4) Others
USB 2.0 interface plug and play, and no need extra power supply;
More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10
Model | Hantek1008C | |
Oscilloscope Mode | ||
Vertical | Analog Channel | 8 |
Input Impedance | Resistance: 1MΩ | |
Input Sensitivity | 10mV/div to 5V/div | |
Input Coupling | DC | |
Resolution | 12 bits | |
Horizontal | Memory Depth | 4K |
Max. Input | 400V (DC+AC Peak) | |
Real-Time Sampling Rate | 2.4MSa/s | |
Time Base Range | 1ns/div to 20000s/div(1-2-5 sequences) | |
Time Base Precision | ±50ppm | |
Trigger | Source | CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8 |
Mode | Edge | |
X-Y Mode | X-Axis Input | CH1 |
Y-Axis Input | CH2 | |
Cursors and Measurement | Voltage Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot |
Time Measurement | Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle | |
Cursors Measurement | Horizontal ,Vertical, Track, Auto Measure Modes | |
Waveform Signal Process | +,- , x,÷, FFT, Invert | |
Voltage Range | 10mV to 5V/div @ x 1 probe | |
100mV to 50V/div @ x 10 probe | ||
10V to 5000V/div @ x 1000 probe | ||
100V to 50000V/div @ x 10000 probe | ||
200mV to 100V/div @ 20:1 | ||
Current Range | 100mA to 50.0A/div @ CC65(20A) | |
1000mA to 500.0A/div @ CC65(65A) | ||
1A to 100.0A/div @ CC650(60A) | ||
10A to 1000.0A/div @ CC650(650A) | ||
1A to 200.0A/div @CC1100(100A) | ||
10A to 2000.0A/div @CC1100(1100A) | ||
Cursor | Time/frequency difference, voltage difference | |
FFT | Rectangular, Hanning, Hamming, Blackman Window | |
Math | Addition, subtraction, multiplication, division | |
Programmable Generator | ||
Channel | 8 | |
Output Level | LVTTL | |
Frequency Range | 0-250kHz | |
Interface | USB 2.0 | |
Power | No need extra power supply | |
Measurement | Size | 185 x 150 x 27 (mm) |
Weight | 0.35KG |
Package Includes:
1 x 1008C DAQ oscilloscope
8 x Crocodile probes/cabl
1 x USB Cable
1 x CD (driver etc.)
1 x Bag