Features:
 
High temperature alarm, when the real-time temperature is higher than the set temperature, the controller will alarm
Low temperature alarm, when the real-time temperature is lower than the set temperature, the controller will alarm
Temperature calibration, temperature can be calibrated as needed
Cooling or heating working mode can be selected
Child lock design prevents accidental opening
Product name: pet house controller
Power supply voltage: AC220V
Output current: MAX 10A
Temperature control accuracy: 0.1℃
Temperature measurement range: -40-120 ℃
Temperature control range: -40-120 ℃
Temperature probe: NTC (10K 0.5%) waterproof sensor, about 1 meter long
Control mode: heating, cooling
Use function description:
On-off key: Short press is switch mode, long press 8S to restore factory settings.
SET key: long press 3S to enter the setting interface, press + - key to select the function code, then short press SET key to enter the setting range of this function, press + - key to adjust the setting range of this function, after 10S there is no any change You can also press the SET key to save and then return to the upper level (other functions can also be adjusted) to automatically save and exit the operation, and then press SET to exit.
Child lock key: It will be automatically locked after 2 minutes without any operation, or it can be locked manually. Short press to enter the child lock function. At this time, all the keys are locked and no response. After long pressing the child lock key for 3S, all key functions will be restored.
Lighting key: short press the control switch.
Sterilization key: short press the control switch, the default is 30min, it can also be set in the P1 function.
Fan key: short press the control switch.
+ - Button: Set the target temperature (if the temperature cannot be reached, it will automatically heat up, try to adjust to the comfortable temperature of the pet), short press to increase or decrease, if it feels too slow, long press to speed up, 10S automatic after adjustment without operation save.
Temperature difference setting: is the parameter between the real-time temperature and the target temperature,
Example: The current target temperature is 30°C, and the temperature difference is set to 2 in the settings. After saving, the heating will stop when the real-time temperature reaches 30°C, and will only be heated when the real-time temperature is less than 28°C.
Correction settings: Adjust when the real-time temperature cannot be reached. Example: The current real-time temperature is 30°C, the adjustment temperature is 2 in the settings, and the real-time temperature after saving is 32°C, which is equivalent to adding two degrees.
Alarm Settings:
Low temperature alarm: After setting the specified temperature in the settings, if the real-time temperature is lower than the set alarm temperature, the buzzer will alarm.
High temperature alarm: After setting the specified temperature in the settings, if the real-time temperature is higher than the set alarm temperature, the buzzer will alarm.
Example: long press SET for 3S and then press + - to adjust to P4, then press SET to adjust the temperature of the high temperature alarm (for example, it is now adjusted to 30), press SET again to save, press again to exit, the temperature of the high temperature alarm is now 30, then When the real-time temperature reaches ≥30℃, the alarm buzzer will sound. Low temperature alarm is the opposite.
Mode Description:
Heating mode: adjust the target temperature to the temperature that needs to be heated, the heating will be automatically started when the real-time temperature is lower than the target temperature, and the heating will be stopped when the real-time temperature is greater than the target temperature. When the temperature drops to the target temperature minus the difference value again, the heating mode is automatically turned on
Cooling mode: Adjust the target temperature to the temperature that needs to be cooled. When the real-time temperature is greater than the target temperature, the cooling will be automatically turned on, and when the real-time temperature is less than or equal to the target temperature, the cooling will be automatically stopped. When the temperature rises again to the target temperature plus the difference value, the cooling mode is automatically turned on
Tips:
1. Unlock the child lock in the sterilization state and automatically close the sterilization
2. The purification and lighting have a memory function. The power will be cut off in the middle of the operation. The set value will be remembered when the power is turned on next time.
3. When restoring the factory settings, the digital tube displays "all bright", and when the sensor is disconnected, the digital tube displays "LLL".
Notice:
1. This product is powered by AC220V, be careful of electric shock! When the load output point is working, there is AC220V voltage. Do not touch for isolation
2. This product cannot be installed in places with dripping water. Please power off when cleaning to avoid electric shock! Pay attention to electricity safety
 
Package List:
Control Panel x1
Power board x1
Transformer x1
  • We accept PayPal only. But we only Accept your Ebay Address,Please Make sure it's 100% right.
  • Payment must be received in 5 business days of auction closing.
  • Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
  • Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.

Fill your shipping info

  • All package need to wait 30 days(US only need 7-10 days),Please take care it.Less than 30 days,we can't take a refund.
  • If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
  • If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.

DataCaciques