Input |
Input Voltage |
AC220V or AC110V(to be specified when placing order) |
|
AC frequency |
47—440HZ |
||
Cold Surge Current |
≤60A(AC220V Input) |
≤30A(AC110 Input) |
|
Current Leakage |
≤0.7mA(AC220V Input) |
≤0.4mA(AC110V Input) |
|
Output |
Maximum Output Voltage |
DC 25KV |
|
Maximum Output Current |
DC 20mA |
||
Efficiency |
≥90﹪(full load) |
||
Mean Time Between Failure (MTBF) |
≥10000H |
||
Response Speed |
≤1ms(from the switch Signal is given to the output current up to 90% of the setting current) |
||
Control Interface |
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification) |
||
Pressure-proof |
Input-Output, Input-Shell: AC1500V 10MA 60S; Output negative is connected with machine shell. |
||
Protection |
can work in open-circuit condition for a short time (Require a good protective earthing and avoid arc between the positive and the machine shell) |
||
Environmental |
Operating Temperature:-10~40℃),Relative Humidity (RH):≤90﹪ |
||
Cooling Way |
Force-Air Cooling (FAC) |
||
Dimension |
L×W×H=167*144*97(mm) |