Detailed Description:

Max Water XLP-4040 2400 GPD Commercial RO Membrane

Specifications


Membrane Features


General Information

                                             
Usage 


It is applicable to the desalination of municipal water, groundwater with salt concentration less than 1000ppm. It can be widely used in pure water preparation and related industries. 

Specifications & Parameters 
Model Active   Membrane Area ft2(m2) Permeate   Flow GPD(T/D) Stable   Rejection Rate (%)
XLP-4040 85(7.9) 2400(9.1) 99.2
Standard Test Condition 
Concentration   of Solution (NaCl) Temperature(℃) pH   Value > Operating   Pressure psi(MPa) Recovery   Rate(%)
500ppm 25 7.5-8 100(0.69) 15

Notes: The permeate flow of single membrane element may vary with in ±15%.

Operating Limits and Conditions of Membrane Element: 

Max.Working Pressure 600 psi(4.14MPa)
Max. FeedWater   Temperature 45 ℃
Max. Feed Water Flow 3.6m3/h
Max. FeedWaterSDI15  5.0
Free Chlorine Concentration of   FeedWater 0.1mg/L
pHRange of FeedWaterDuring Continuous Operation 2-11
pHRange of FeedWaterDuring Chemical Cleaning 1-13
Max. Pressure Drop of Single   Membrane Element 15psi(0.1Mpa)

               