Continous power is 15KW ,surge power is 45KW .
This is power/low frequency power inverter and battery charger.
The difference between power /low frequency and high frequency:
The power /low frequency inverter converts the DC power into low frequency low-voltage AC power firstly, then boosts into 220V 50Hz AC power for the load through the low frequency transformer. Its advantage is that the structure is simple, and various protection functions can be realized at lower voltages. Because there is a low frequency transformer between the inverter and load, the inverter runs stably, reliably, with strong overload capacity and shock resistance, and can suppress the high-order harmonic elements in the waveform.
The high frequency inverter converts low-voltage direct current into high-frequency low-voltage alternating current through high frequency DC/DC conversion technology firstly. After the high-frequency transformer is boosted, it is rectified by the high-frequency rectifier filter circuit to a high-voltage direct current, usually above 300V high-voltage direct current; finally, the 220V low frequency alternating current is obtained for the load through the low frequency inverter circuit.
Note:
The same product /weight to different country/zone with different shipping freight,so please consult us.
Wood box package. 94Kg 82*55*42cm
It is stored in Rancho Cucamonga,CA,USA warehouse 91739.
Certainly , i suggest you contact the local logistics to pick up with the best cost.
it is more than 150 lbs which not accept by UPS.
|
Optional Configuration with different FOB price and shipping freight :
15KW DC48V AC120V&240V
HP Series Pure Sine Wave Inverter & MPPT & Charger
HP-PV Series Pure Sine Wave Inverter is a combination of an inverter, charger, solar power and Auto-transfer switch into one complete system . It is packed with unique features and it is one of the most advanced inverter/chargers in the market today.
Feature of HP Series Inverter & MPPT & Charger
Electrical Specifications | ||||||||||||
Inverter Output | Model | 1KW | 1.5 KW | 2KW | 3.KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | 15KW |
kContinuous Output Power | 1KW | 1.5 KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | 15KW | |
Surge Rating (20Secs) | 3KW | 4.5 KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | 45KW | |
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | |||||||||||
Nominal Efficiency | >88%(Peak) | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||||||||||
Output Voltage Regulation | ±10% RMS | |||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||||||
Typical transfer Time | 10ms(Max) | |||||||||||
THD | < 10% | |||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc/24.0Vdc/48.0Vdc | 24.0Vdc/ 48.0Vdc | 48.0Vdc | ||||||||
Minimum Start Voltage | 10.0Vdc/ 10.5Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc ; | ||||||||||
Low Battery Alarm | 10.5Vdc/ 11.0Vdc for 12Vdc Mode | |||||||||||
Low Battery Trip | 10.0Vdc/ 10.5Vdc for 12Vdc Mode | |||||||||||
High Voltage Alarm | 16.0Vdc for 12Vdc Mode | |||||||||||
Low Battery Voltage Recover | 15.5Vdc for 12Vdc Mode | |||||||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On. | |||||||||||
Charger | Output Voltage | Depends on battery type | ||||||||||
Charger Breaker Rating | 20A | 20A | 20A | 25A | 32A | 40A | 40A | 50A | 80A | 80A | 80A | |
Max Charge Power Rate | 1/3 Rating Power | |||||||||||
Battery Initial Voltage for Start | 10-15.7Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc ; | ||||||||||
Over Charge Protection Shutdown | 15.7Vdc for 12Vdc Mode | |||||||||||
BTS | Battery Temperature Sensor (Optional) | Yes Variances in Charging Voltage & S.D Voltage Based on the Battery Temperature.
| ||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||||||
Nominal Voltage | 100-110-120Vac / 220-230-240Vac | |||||||||||
Max Input AC Voltage | 150VAC For 120Vac LV Mode; 300VAC For 230Vac HV Mode; | |||||||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||||||
Overload protection (SMPS load) | Circuit Breaker | |||||||||||
Output Short circuit protection | Circuit Breaker | |||||||||||
Bypass Breaker Rating | 20A | 20A | 20A | 25A | 32A | 40A | 40A | 50A | 80A | 80A | 80A | |
Transfer switch Rating | 30Amp for UL & TUV | 40Amp for UL | 80Amp for UL | |||||||||
Bypass Without Battery Connected | Yes (Optional) | |||||||||||
Max Bypass Current | 30Amp | 40Amp | 80Amp | |||||||||
Solar Charger (Optional) | Rated Voltage | 12Vdc / 24Vdc / 48Vdc | ||||||||||
Solar Input Voltage Range | 15-45Vdc / 30-70Vdc / 60-100Vdc | |||||||||||
Rated Charge Current | 40 or 60A | |||||||||||
Rated Output Current | 15A | |||||||||||
Self Consumption | < 10mA | |||||||||||
Bulk Charge (Default) | 14.5Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc | ||||||||||
Floating Charge(Default) | 13.5Vdc for 12Vdc Mode | |||||||||||
Equalization Charge(Default) | 14.0Vdc for 12Vdc Mode | |||||||||||
Over Charge Disconnection | 14.8Vdc for 12Vdc Mode | |||||||||||
Over Charge Recovery | 13.6Vdc for 12Vdc Mode | |||||||||||
Over Discharge Disconnection | 10.8Vdc for 12Vdc Mode | |||||||||||
Over Discharge Reconnection | 12.3Vdc for 12Vdc Mode | |||||||||||
Temperature Compensation | -13.2mV/°C for 12Vdc Mode | |||||||||||
Ambient Temperature | 0 ~ 40°C(Full load) 40 ~ 60°C(Derating) | |||||||||||
Mechanical Speccifications | Mounting | Wall Mount | ||||||||||
Inverter Dimensions (L*W*H) | 388*415*200mm | 488*415*200mm | 588*415*200mm | 706*415*212mm | ||||||||
Inverter Weight (Solar Chg) KG | 21 +2.5 | 22 +2.5 | 23 +2.5 | 27 +2.5 | 38 +2.5 | 48 +2.5 | 49 +2.5 | 60 +2.5 | 66 +2.5 | 70 +2.5 | 83+2.5 | |
Shipping Dimensions (L*W*H) | 550*520*310mm | 650*520*310mm | 750*520*310mm | 900*540*410mm | ||||||||
Shipping Weight (Solar Chg)KG | 23 +2.5 | 24 +2.5 | 25 +2.5 | 29 +2.5 | 40 +2.5 | 50 +2.5 | 51 +2.5 | 62 +2.5 | 68 +2.5 | 72 +2.5 | 95+2.5 | |
Display | Status LEDs / Status LEDs+LCD | |||||||||||
Standard Warranty | 1 Year |
Note: Specifications subject to change without notice.
Attention:
Before you paying the order, you should see the technical parameter carefully and confirm the inverter / automatic voltage regulator / stabilizer / solar controller / transformer / uninterrupted power supplier (UPS) can meet your requirement and solve your problem.
Besides, tell me the specification and parameters of what you want to buy; the express address to calculate the shipping freight; the input voltage range and rated output voltage.
Inverter : if you want to buy, please tell us the below parameters:
Where do you need the inverter used for ?
What’s the type of the load and the total load capacity ? (xxx W /xxx KW)
What’s the input DC voltage ? (12V? 24V? or 48V?)
What’s the output AC voltage do you need? (220V? 110V? 120V or 120V/240V complementary ? )
What’s the kind of your battery ? (Lead-acid? Colloidal? Lithium or others) If you used the Lithium battery, please share the battery parameters with us to matching the inverter, such as the Rated voltage, Over voltage & Under voltage protecting parameter. unless you will buy it from us.
What’s the type of your charging power ? (Utility power ? Solar Power ? Or the Generator Power ? )
If you have the solar power, do you need the related MPPT ? If yes, please share the total capacity of solar panels. (xxx W /xxx KW)
If you need the related MPPT, do you need the external single MPPT or the build-in MPPT ? (The build-in MPPT is built into the Inverter as an integrated Inverter. )