Brand New Original FLUKE 106 Palm-sized Digital MultiMeter

 

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.


  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])


Accuracy Specifications
FunctionRangeResolutionAccuracy
AC Volts16.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 3
Diode Test22.000 V0.001 V10 %
Resistance 
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance350.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle41 % to 99 %0.1 %NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection RatioNormal Mode Rejection Ratio
AC Volts600 V 1>10 MΩ <100 pF 2>60 dB at dc,
50 Hz or 60 Hz
AC Millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz
DC Volts600 V 1>10 MΩ <100 pF>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground600 V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AAA, NEDA 24A, IEC LR03
Battery Life200 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative Humidity
Operating HumidityNon-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL)142 mm x 69 mm x 28mm
Weight200 g
IP RatingIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326-1: Portable
Electromagnetic CompatibilityApplies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.



Model NameDescription
Fluke 106

Includes:

  • Fluke 106 Palm-sized Digital Multimeter
  • Test Leads
  • User’s Manual

 Please note: this meter is made by FLUKE in China.

 

I. PAYMENT

We accept PayPal and all major credit cards, including Visa, Master Card,, American Express, Discover, etc. 

II. SHIPPING

We ship by Australia Post or others ways per customer's request.
We ship out product every 3 days

III. RETURN/EXCHANGE 

Return Policy:
1. There is a 5% or 15% restocking fee for unopened or opened items respectively.
2. Items with marks or alternated cannot be returned because we cannot resell them.
3. Items should be returned with original packaging materials and accessories.
4. Please put a note inside the package indicating your eBay user name, purchase date, and the reasons for returning.
5. Buyers pay for shipping the items back and the original shipping fee to the buyer will be deducted from the refund.

IV.CUSTOMER SERVICE

We have full time staff answering phone calls for technical and sales related question from 8am to 5pm AEST and reply eBay or email messages within 1 day.
Please feel free to send us messages, we are all ears. 

About this instrument: our company, Analog Technologies, Inc., has been designing and developing analog electronic products for 24 years. 
This meter has been used and highly recommended by our electrical engineers. 
Its user manual can be found online or downloaded from our company's website. 
That's why we are selling it here with the confidence that you will like it as well. 
Only if you are happy with our products and services then we will be happy.

About us: Our company, Analog Technologies, Inc., was started as an R&D firm in January 7, 1997, in Novi, Michigan, a small town 25 miles from Detroit.
After 24 years hard working, we have established branches in San Jose, California, USA; Sydney, Australia; and Anshan, Liaoning, P.R. China.
We have 3 departments: R&D, Production and Trading.
The products sold on eBay are either produced by our own Production Department or our sub-contractor companies.
If you have any questions and/or suggestions, please contact us. Our goal is to make our customers happy and grow our company to a bigger one