Description:   
This equipment heating up fast,precise temperature can be set to automatically control the time,in-cylinder temperature over 100 degrees Celsius,automatic over-temperature shutdown protection,safer!.   
Manually open and pressure adjustable,Automatic,manual pressurization and pressure relief,pressure over 8KG auto exhaust,overpressure protection and safer!.   
Special steel lock nut,durable!And can be replaced individually,without affecting the cylinder(other brands nut slip teeth tank must be replaced,otherwise unsafe)Cylinder with stainless steel pallets,cylinders never rust.   
|
Operation:   
Turn left to rotate the handle to open the lid, put the product back, close the lid, the first big right hand side of the buckle Ping matter, then turn to four hours on a rotating right hand Bing tightening. Turned into the trachea, after setting the exhaust time press the power switch, the machine into the boot state. Set the desired temperature, the selector switch is turned to the automatic position to start the automatic intake, heating switch is pressed, the machine starts Debubblers work, arriving exhaust time, automatic pressure let go, in addition to soak completed, shut down after out products. After the first adjustment after good use, re-use as long as the product into the tank, shut the lid, the boot can be done automatically Debubblers.   
1. Set the temperature, press the SET button for 2 seconds. SV display flashes, press the Up and Down keys to the required temperature, then press the SET button, setup is complete.   
2. Set the exhaust time, first set the time unit, S for seconds, M for minutes, H for hours, left number is ten and a bit to the right of the decimal point two units, such as setting (10M00) is 10 minutes except bubble. Press the button for the addend, subtrahend press the button for each set-up time must be in the off state, otherwise fail!.   
3. automatic exhaust equipment is not heated.   
4. The device for safety reasons, automatic exhaust gas pressure exceeds 8 kg, the temperature over 120 degrees automatically shut down, the water does not slip lid nut teeth, such as tooth wear silk can be replaced individually tooth wire, does not affect the air pot use, is a safe, durable and good product.   
5. Pressure Air Filter Co., dial from round knob, clockwise the pressure, counterclockwise rotation reducing stress, after a good tune knob is pressed, setup is complete. Or the knob clockwise to the minimum, then the filter is not reduced.   
6, before opening the lid, if there is pressure, the selector switch is turned to the run-flat position, the machine immediately discouraged, and then open the lid when the pressure is zero.   
|
Parameter:   
Power supply:220V.   
Power:1250W.   
Tank size: 158*200mm.   
Size:30*25*30cm.   
Weight:20KG.   
|
What in Package:   
1 x Set of OCA Bubble Remove machine.   
|