M42300 is a high quality and durable DC voltmeter with accuracy class
of 1.5%.
Measurement range: 0-100V . Panel setting. Size 3.15x3.15inch (80x80mm).
You can use this panel meter to monitor battery voltage or to test your wind turbines, solar panels, battery charging.
Average
life service time
is 12 years. Warranty: 1year.
Overload resistant!!!
Please read this description till
the end:
1. You will understand why device M42300 costs
more than cheap ammeters and voltmeters.
2. You will see M42300
benefits over its analogs.
Due
to design specifics of measuring mechanism and
high-quality plastic case (IP54) device
is vibration and shock proof. It can be used outdoors because the case of M42300 is
protected from getting dust
on measuring mechanism and from rain and
water splashes. Temperature range
from -60 ˚ C to
+50 ˚ C.
64000 items of DC and AC micro ammeters,
milli ammeters, ammeters, kilo ammeters milli voltmeters
volt meters, kilo voltmeters are available in our stock.
Altogether 136 measurement ranges and 41 standard sizes. There are devices
with zero in the middle and zero in the left.
Device’s photos may not coincide with nominal value because of the large
number of available ranges.
You will receive device
in accordance with the ordered range.
Photos of device M42300:
Front view Rear view
Side view Top view
Angle view (please, note the marks below device’s scale)
If
you buy more,
you’ll save up to 4 times for shipping.
I
do not ship my items for free. High quality and reliable shipping costs money.
Products are always carefully packed
before shipping. Package has a
certain weight.
And is shipped
like a small
package, rather than a simple letter.
Shipping
cost depends
on quantity and type of shipping:
Quantity of pc. M42300 |
Shipping type |
|||
Simple |
Avian (Par avion) |
|||
Total shipping price for whole load |
Actual
shipping price for 1pc. |
Total shipping price for whole load |
Actual shipping price for 1pc. |
|
1 |
6.98$ |
6.98$ |
8.03$ |
8.03$ |
2 |
10.33$ |
5.17$ |
12.25$ |
6.13$ |
3 |
15.40$ |
5.13$ |
18.82$ |
6.27$ |
4 |
15.40$ |
3.85$ |
18.82$ |
4.71$ |
5 |
15.40$ |
3.08$ |
18.82$ |
3.77$ |
6 |
27.41$ |
4.57$ |
28.70$ |
4.78$ |
7 |
27.41$ |
3.92$ |
28.70$ |
4.10$ |
8 |
27.41$ |
3.43$ |
28.70$ |
3.59$ |
9 |
27.41$ |
3.05$ |
28.70$ |
3.19$ |
10 |
27.41$ |
2.74$ |
28.70$ |
2.87$ |
15 |
36.23$ |
2.42$ |
50.01$ |
3.33$ |
20 |
41.28$ |
2.39$ |
59.68$ |
2.98$ |
25 |
48.35$ |
2.06$ |
69.38$ |
2.77$ |
50 |
95.74$ |
1.92$ |
137.38$ |
2.75$ |
100 |
189.54$ |
1.89$ |
271.97$ |
2.72$ |
The price in the table is approximate. It depending on your location and changing of shipping cost by post office.
To have actual information please write me mail.
As you may see from the table, the more devices you order the less you pay for shipping.
Your shipping economy is over 75%.
This device NEW (not used). I have a lot of device in my stock. Biggest part of them is 2008-2010 year of manufacture.
Some values were made between 1985 and 2008. They are tested and 100% workable.
Also I can supply 2012 year of manufacture but this device will be more expensive.
Basic technical characteristics
of milli ammeter M42300:
Current type: constant.
Measurement range: 0-100V.
(Devices with zero in middle at the range
of 100-0-100V are also available in stock).
Accuracy class: 1.5%.
(by additional request the devices with 1% accuracy class can be supplied).
Overall and mounting dimensions:
Setting type: panel. Horizontal or vertical,
depending on the order.
Front panel dimensions: 80 x 80 x 14mm / / 8 x
8 x 1.4cm / /
3.15 "x 3.15" x 0.55 "(L * W * T);
Setting dimensions:
- Hole diameter
69mm / / 6.90cm / / 2.7 ";
- Depth: 33mm / / 3.3cm / / 1.3 ";
Dimensions: ammeter M42300.
А - 80mm // 8cm // 3.15";
В – 33mm // 3.3cm // 1.30";
С – 14mm // 1.4cm // 0.55";
D - 69mm // 6.9cm // 2.72";
D1 – 71mm // 7.1cm // 2.80";
d - 3.5mm // 0.35cm // 0.14";
Е – 68mm // 6.8cm // 2.68".
Use conditions:
Air temperatures: from -60 ˚ C to +50 ˚ C.
Humidity: up to 98%.
Vibration resistance:
device can withstand vibration of acceleration from 5 to 30 m/s2
(0.5-3G) with a frequency from 10Hz to70Hz
during 7 minutes.
Shock resistance: device can withstand shocks with
acceleration of 100 m/s2
(10G) at a frequency up to 50 beats per minute.
Device’s case:
Device is made in high-quality plastic case. Protection degree of device’s case corresponds to IP54: Case is protected from getting dust,
rain and water
splashes.
This allows to use the device in moving objects (trains, ships, electric cars) and outside. For example, these devices are used in ukrainian and russian underground.
Front panel material: natural glass scratch resistant. Contains calcium oxide, which provides additional material strength.
Overload resistance:
Ammeters and voltmeters
M42300 withstand current
or voltage overload. This device can
withstand for 2 hours of load equal to 120% of the upper
measurement range limit.
Delivery
set:
- Device M42300, 1
pc.;
- Nut (brass
coated with nickel), 6 pcs. + 2 pcs. on device contacts;
- Metal washer (brass
coated with nickel), 8 pcs. + 2 pcs. on device contacts;
- Metal spring washer,
6 pcs. + 2 pcs.
on device contacts;
- Packing carton
box, 1pc;
- Packing paper, 2
pcs.
Device M42300 delivery set photo:
Device M42300 package:
Device
M42300 mounting
set:
Passport and quality certificate:
Measurement ranges:
M42300 is universal device for current strength or DC voltage measurements.
M42300 can be milli ammeter, ammeter, kilo ammeter, voltmeter, kilo voltmeter.
Devices with other measurement ranges and with zero in the middle of scale are
available in stock.
M42300 have some analogs. Like M42100, M4200 and M4213.
They have the same technical characteristic like M42300 (some changes in the case).
Together M42300, M42100, M4200 and M4213 models has a lot nominals.
All of them can be of direct and indirect turn on (through shunt or additional
resistance):
- 1mA, 2mA, 5mA, 10mA, 15mA, 20mA, 30mA, 50mA, 100mA, 150mA, 300mA,
500mA,
600mA, 3/30mA, 3/50mA, 5/50mA, 1A, 2A, 3A, 5A, 10A, 15A
(way of turn on devices
milli ammeters and ammeters M42300 - direct);
- 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 500A, 750A, 1000A, 1500A,
2000A, 4000A, 6000A (way of turn on devices ammeters and kilo ammeters M42300 -
with an external shunt in 50mV and 60mV, 75mV, 100mV, 125mV;
- 0.025V; 0.050V; 0.075 V; 2V, 3V, 7.5 V; 10V, 15V, 20V, 30V, 50V, 75V, 100V, 150V,
250V, 300V,
500V, 600V (way of turn on devices milli voltmeters and voltmeters M42300 -
direct);
- 150/1500V; 15/150/1500V, 1000V, 1500V, 3000V and more at order (way of turn
on
devices - with a separate calibrated additional resistance with nominal
current of 5mA).
If I wouldn’t have M42300 with the nominal you need I will send M42100, M4200 and M4213.
This is the same quality devices only has some changes in the case.
All required shunts and additional resistance are also available in stock.
If
you need shunts, transformers or additional resistance please contact me.
Please take a look at shunts, transformers and aditional resistance at my Ebay store, usig the link:
Ammeters, voltmeters, watt meters, var meters, phase meters with other typical sizes are also available in stock:
40х40mm; 60х60mm; 80х80mm; 120х120mm; 160х160mm; 48х48mm; 72х72mm; 96х96mm;
30x30mm; 32х100mm; 37х38mm; 40х21mm; 42х42mm; 50х25mm; 53х46mm; 54х21mm; 63х63mm;
74х26mm; 80x120mm; 83х83mm; 85х85mm; 88х60mm; 90х100mm; 96х30mm; 100х30mm; 120х30mm;
120х60mm; 120х105mm; 121х131mm; 125х110mm; 140х42mm; 144х144mm; 160х30mm; 160х60mm;
160х80mm; 160х140mm; 160х175mm; 230х180mm; 240х30mm; 250x120mm.
Device test before shipment:
All devices are tested in our certified laboratory before shipment.
DC ammeters and voltmeters
testing are provided at calibrators (high precision DC generator) P320.
Calibrator’s accuracy class is 0.02%.
Testing method: selection value of calibrator P320 output signal relative to the nominal value on device M42300. Nominal value is that,where the pointer of device M42300.
For
example, will show several stages of DC voltmeter M42300 testing
with measurement range
of 0-150V.
Control points will be 10V, 50V,
75V, 100V, 150V.
Output voltage P320: 50.224V; Power on display M42300: 50V; M42300 relative error: (50.224V-50V)/50.224V*100%=0.45% Permissible error: 1.5% Conclusion: device M42300 is in accuracy class. |
|
Output voltage P320: 75.412V; Power on display M42300: 75V; M42300 relative error: (75.412V-75V)/75.412V*100%=0.55% Permissible error: 1.5% |
|
Output voltage P320: 100.624V; Permissible error: 1.5% |
|
Output voltage P320: 150.840V; Permissible error: 1.5% | |
Output voltage P320: 150.840V;
Power on display
M42300: 150V; Permissible error: 1.5% |
Testing conclusion: voltmeter M42300
corresponds to accuracy class 1.5%.
This model even corresponds to accuracy class of 1%.
Ammeters and voltmeters M42300 are more expensive than other cheap analogs.
This is due to high accuracy and high reliability of
the device.
Technical
characteristics of M42300 dominated
over characteristics of other cheap
devices.
If you need reliable, exact and durable measuring
device,
then you should buy M42300.
If you are looking for a
cheap indicator with low accuracy
then
choose cheap analog indicators.
To facilitate your choice, please
take a look at a comparative table of device
M42300 and cheap
ammeter.
Parameter |
M42300 |
Cheap device |
Accuracy class |
±1.5% |
±5% or ±2.5% |
Mean time between failures |
92250 hours. ( More than 10 years of continuous
work) |
12500 hours (1.5 year) |
Overload resistance |
The device can withstand for 2 hours of load equal to 120% of the
upper measurement range limit. |
Research was carried out: |
|
||
Case |
High-quality, shock
resistant plastic.
Do not crack or
crumble by shocks.
|
Cheap plastic. When bump and fall it cracks. |
Front panel |
Natural glass scratch
resistant. Contains calcium
oxide, which provides additional material strength. |
1. Plastic. Not
scratches and cracks
resistant. |
Weight |
120g. |
102 g. |
Weight with package |
150g. |
110g. |
|
||
Content of non-ferrous and precious metals |
|
|
- aluminum, |
11g. |
7g. |
- copper |
17 g.
|
9 g.
|
- silver |
Silvered contacts 0.01g. |
NO silver. |
|
||
Manufacturer |
Plant "Elektroprybor", Russia. The
plant has an award of red mark. |
Small factory. |
Manufacturer price per one item |
36USD.
|
2.5-3USD. |
Warranty |
1 year |
None or up to 1year. |
|
|
|
Ammeter M42300, voltmeter M42300, milliampermetr M42300, kiloammeter
M42300, kilovoltmeter M42300 are designed
to measure current and voltage in
DC electrical circuits.
Devices can measure currents in range from 10mA to
20A and voltages from 25mV to 750V at direct turn on.
For current and voltage measurements, that excess limits, external shunt and
additional resistor are applied (ordered
separately).
Mean time between failure of device
M42300 (m), microammeter
M42300 - 55000 hours,
devices M42300 - 92250
hours;
Devices average life service is 12 years;
Design concept of device ammeter M42300,
voltmeter M42300, milliammeter M42300,
kiloammeter M42300, kilovoltmeter
M42300 cases provides protection degree
in front panel IP50, or IP54, for
current-carrying parts - IP00.
Devices ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300 can withstand long current
or voltage overload, equal to 120% of the higher measurement limit range for 2 hours;
Device is filled with high-quality plastic case that can
be used in hard conditions.
Calibrated wire, connecting device with shunts, are supplied (at customer's request). It is possible to manufacture devices with increased protection on request.
Devices ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300 DC can be produced with zero mark at the beginning or
at middle of scale;
Devices scale can be implemented in any physical measurement units, with
special markings, inscriptions and so on according to the customer’s request.
Normal position of ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300,
kilovoltmeter M42300 - vertical or
horizontal. Manufacture of device with other measurement ranges is possible on
request.
Technical characteristics of devices ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300:
Dimensions – 80x80mm, cutout in panel d – 77.5 mm;
Weight - 0.2 kg;
Other dimensions of devices ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300,
kilovoltmeter M42300 shown in figure
1;
where A - 80mm, B - 45mm, C - 12mm, D – 73.7 mm, D1 – 77.5 mm, d – 3.4 mm, E -
68mm;
Accuracy class - 1.5; 2.5;
Measuring ranges:
- 5mA;
10mA; 15mA; 20mA;
30mA; 50mA; 100mA;
150mA; 300mA; 500mA;
600mA; 3/30mA; 3/50mA;
5/50mA; 1A; 2A;
3A; 5A; 10A;
15A (devices ammeter M42300, milliammeter M42300, kiloammeter
M42300 way of turn on - directly);
- 15A;
20A; 30A; 50A;
75A; 100A; 150A;
200A; 300A; 500A;
750A; 1000A;1500A;2000A; 4000A; 6000A
(way of turn on with external shunt of 75 mV);
- 0.025 V; 0.050 V; 0.075
V; 2V; 3V;
7.5 V; 10V; 15V;
20V; 30V; 50V;
75V; 100V; 150V;
250V; 300V; 500V;
600V (way of turn
on of voltmeter M42300, kilovoltmeter
M42300 - directly);
- 150/1500V;
15/150/1500V, 1000V, 1500V, 3000V (way
of turn on - with
a separate calibrated additional
resistance P4201 with
nominal current of 5 mA).
Measurement range, voltage or current full
deflection and way of turn on devices ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300 are
shown in table 1;
Table 1: Measurements
range, voltage or current full deflection and way
to turn on devices ammeter M42300,
voltmeter M42300, milliampermetr M42300, kiloampermetr M42300, kilovoltmeter M42300
Measurement
range, mA |
Voltage drop, mV, |
Way of turn on |
|
with zero mark on edge of the range |
with zero mark within the
range |
||
0mA-1mA 0mA-5mA 0mA-10mA 0mA-15mA 0mA-20mA 0mA-30mA |
1mA-0mA-1mA 5mA-0mA-5mA 10mA-0mA-10mA 15mA-0mA-15mA 20mA-0mA-20mA 30mA-0mA-30mA |
605mV 190mV 75mV 87mV 90mV 50mV |
Direct |
0mA-50mA 0mA-100mA 0mA-150mA 0mA-300mA 0mA-500mA 0mA-600mA |
50mA-0mA-50mA 100mA-0mA-100mA 150mA-0mA-150mA 300mA-0mA-300mA 500mA-0mA-500mA 600mA-0mA-600mA |
95mV |
|
0mA-3mA/30V 0mA-3mA/50V 0mA-5mA/50V |
3mA/30V-0mA-3mA/30V 3mA/50V-0mA-3mA/50V 5mA/50V-0mA-5mA/50V |
605mV |
|
0А-1А 0А-2А 0А-3А 0А-5А 0А-10А 0А-15А |
1А-0А-1А 2А-0А-2А 3А-0А-3А 5А-0А-5А 10А-0А-10А 15А-0А-15А |
95mV |
Direct |
0А-15А 0А-20А 0А-30А 0А-50А 0А-75А 0А-100А 0А-150А 0А-200А 0А-300А 0А-500А 0А-750А 0А-1000А 0А-1500А 0А-2000А 0А-4000А 0А-6000А - |
15А-0А-15А 20А-0А-20А 30А-0А-30А 50А-0А-50А 75А-0А-75А 100А-0А-100А 150А-0А-150А 200А-0А-200А 300А-0А-300А 500А-0А-500А 750А-0А-750А 1000А-0А-1000А 1500А-0А-1500А 2000А-0А-2000А 4000А-0А-4000А 6000А-0А-6000А 200А-0А-750А |
75mV |
With interchangeable fixed shunt of 0.5 accuracy
class and calibrated wire |
Measurements
range, V |
Current of full deflection, mA, not more than |
Way of turn on |
|
with zero mark on edge of the range |
with zero mark within the
range |
||
0V-0.025V |
0.025V-0V-0.025V |
|
With calibrated wire of 0.035 Ohm resistance, |
0V-1V 0V-2V 0V-3V 0V-7.5V 0V-10V 0V-15V 0V-20V 0V-30V 0V-50V 0V-75V 0V-100V 0V-150V 0V-250V 0V-300V 0V-500V 0V-600V |
1V-0V-1V 2V-0V-2V 3V-0V-3V 7.5V-0V-7.5V 10V-0V-10V 15V-0V-15V 20V-0V-20V 30V-0V-30V 50V-0V-50V 75V-0V-75V 100V-0V-100V 150V-0V-150V 250V-0V-250V 300V-0V-300V 500V-0V-500V 600V-0V-600V |
1.1mA |
Direct |
0V-3V/30V 0V-3V/300V 0V-30V/300V 0V-4V/100V 0V-7.5V/300V 0V-8V/300V 0V-10V/100V 0V-15V/150V 0V-15V/300V 0V-20V/40V |
3V/30V-0V-3V/30V 3V/300V-0V-3V/300V 30V/300V-0V-30V/300V 4V/100V-0V-4V/100V 7.5V/300V-0V-7.5V/300V 8V/300V-0V-8V/300V 10V/100V-0V-10V/100V 15V/150V-0V-15V/150V 15V/300V-0V-15V/300V 20V/40V-0V-20V/40V |
1.1mA |
Direct dual- channel |
0V-1000V 0V-1500V 0V-3000V |
1000V-0V-1000V 1500V-0V-1500V 3000V-0V-3000V |
5mA |
With
additional resistance
at nominal current 5 mA |
0V-150V/1500V 0V-15V/150V/1500V |
- - |
With
additional resistance
at nominal current 5 mA and
R=300 kOhm |
Acceptable basic error limits of devices ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter
M42300, kilovoltmeter M42300 is:
- ± 1.5% - for devices of accuracy class 1.5;
- ± 2.5% - for devices of accuracy class 2.5;
without taking into account errors of
individual external shunts and
additional resistances;
Normalizing values
in determining of errors are equal to:
- The highest
measured range - for devices
ammeter M42300, voltmeter
M42300, milliammeter M42300,
kiloammeter M42300, kilovoltmeter M42300 with zero mark on edge of
the measuring range;
- sum of
the highest measurement range modules
limits - for units with zero mark within the
edge of the measuring range;
Acceptable variations
limit in devices: ammeter M42300,
voltmeter M42300, milliammeter M42300, kiloammeter M42300,
kilovoltmeter M42300 measurements
are equal to a half of acceptable basic error limit;
Indicator deviation from zero scale mark after 30 seconds filing on device measured
value, corresponds to the highest
measurement range limit, does not exceed values:
- for accuracy class 1.5 - 0.9mm;
- for accuracy class 2.5 - 1.5 mm;
Devices ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter M42300,
kilovoltmeter M42300 measurement changes,
caused by its position change from its normal to any direction for 45
° (except microammeter), does not exceed acceptable basic error limit. Measurement changes must be
expressed in the form of reduced
error;
Measurement changes, caused by influence
of an external homogeneous constant
magnetic field with induction of 0.5mT
under the most unfavorable direction of
magnetic field, does not exceed
± 1.5%;
Index deviation from the rest position after a sudden excitation. Caused
by changes in the final measurements of 2/3 from scales length, does not exceed
± 1.5% at the end of the scale length in 4c;
Change of ammeter M42300, M42300 voltmeter,
milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300 pointer does not
exceed 20% of the scales length;
The insulation between the case and insulated from the
case electric circuits stands for 1 minute action of the test voltage of alternating
current frequency of 50 Hz ± 1 Hz. rms value of which corresponds to:
- Under normal using conditions - 2.0kV;
- At higher humidity in the working conditions -
1.2kV;
Devices M42300 ammeter, M42300 voltmeter, M42300 milliammeter,
M42300 kiloammeter, M42300 kilovoltmeter designed for turn on into a network with a
voltage of over 650V, must be isolated in the field and should be specially marked;
coresponds to those shown in Table 2.
Table 2: Insulators test voltage
Insulators
test voltage,kV. used on the higher
measurement ranges V |
Relative
humidity 20 º C ± 5 ° C |
||
1000 kV |
1500 kV |
3000kV |
|
3V 1.8V |
5V 3.2V |
7V 5V |
30%-80% 95% |
Resistance insulation between the case and isolated dc
electric circuit of devices ammeter M42300, M42300 voltmeter, milliammeter
M42300, kiloammeter M42300, kilovoltmeter M42300 is not less than:
a) 20 MOhm - at an ambient temperature of +20 º C ± 5
° C and relative humidity from 30% to 80% at operating voltage up to 1kV. plus 20 MOhm
for each further complete and incomplete 1000V of working voltage;
b) 5 MOhm - at an ambient temperature of +60 ° C and
relative humidity of 80% at an operating voltage up to 1kV. plus 0.5 MOhm for
each further complete or incomplete 1000V of working voltage;
a) 2 MOhm - at ambient temperature +20 º C ± 5 ° C and
relative humidity of 95% at an operating voltage up to 1kV. plus 0.5 MOhm for
each further complete or incomplete 1000V ofworking voltage;
Devices can withstand without damage short-term reload
in accordance with Table 3.
Table 3
Devices mark |
Current
multiplicity corresponds to the highest measurement range |
Voltage
multiplicity corresponds to the highest measurement range |
Quantity of reloads |
Reload duration |
Interval between two loads |
Ammeters (besides 3A; 5A; 10A).
milliammeters and microammeters |
10 10 |
- - |
9 1 |
0.5s 5s |
60s - |
Ammeters 3A; 5A; 10A |
10 10 (3*) |
- - |
9 1 |
0.5s 5s |
60s - |
Voltmeters |
- - |
2 2 |
9 1 |
0.5s 5s |
60s - |
* In
agreement with the consumer. |
Ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter
M42300. kilovoltmeter M42300, measurement deviation caused by the ambient temperature change
from the normal 20 º C ± 5 ° C to any temperature between -50 º C to +60 ° C for every
10 ° C temperature change,
does not exceed 0.5 of acceptable basic error limit;
Measurement changes, caused by deviation of the
relative humidity from the normal 30% -80% at 20 º
C ± 5 ° C to
95% at +35 ° C,
does not exceed acceptable basic error limit;
Devices M42300
(m) manufactured for
use in temperate climates have
the resistance to cyclical effects of
ambient temperature:
Cyclic temperature
effects:
- Higher temperature +65 º
C;
- Low
temperature - 50 º C;
- Cycle
time - 2:00;
- The number of cycles - 2;
Humidity impact
on the ammeter M42300,
voltmeter M42300, milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300:
- Relative humidity - 98%;
- Temperature - +40 º C;
- Moisture
resistance duration - 2 days;
- Humidity resistance duration - 8 days;
Devices retain
their characteristics after vibration
influence with acceleration and
frequency, shown in Table 4.
Table 4: Impact
of vibration acceleration and
frequency on ammeter M42300, voltmeter
M42300, milliammeter M42300,
kiloammeter M42300, kilovoltmeter
M42300
Type of device |
acceleration m/s2 |
Frequency, Hz |
Holding time at each frequency, min |
M42300 |
5 m/s2 10 m/s2 15m/ s2 20m/ s2 20m/ s2 25m/ s2 30m/ s2 30m/ s2 |
10 Hz 20 Hz 30 Hz 40 Hz 45 Hz 50 Hz 60 Hz 70 Hz |
7 minutes 7 minutes 7 minutes 7 minutes 8 minutes 8 minutes 8 minutes 8 minutes |
M42300 (m) |
2m/ s2 5m/ s2 15m/ s2 20 m/s2 |
10 Hz 20 Hz 30 Hz 40 Hz |
15 minutes 15 minutes 15 minutes 15 minutes |
Devices produced for nuclear power stations (NPPs) withstand seismic
effects equivalent to the effects
of vibration parameters shown in
table 5;
Table 5
Frequency, Hz |
5 Hz |
6 Hz |
8 Hz |
12 Hz |
||
Acceleration, m/ s2 |
Direction |
Horizontal |
11m/ s2 |
15m/ s2 |
15m/ s2 |
15m/ s2 |
Vertical |
7.7m/ s2 |
10.5m/ s2 |
10.5m/ s2 |
10.5m/ s2 |
||
Frequency, Hz |
26 Hz |
28 Hz |
30 Hz |
32 Hz |
||
Acceleration, m/ s2 |
Direction |
Horizontal |
5.0m/ s2 |
3.7m/ s2 |
1.8m/ s2 |
1.8m/ s2 |
Vertical |
3.5m/ s2 |
2.6m/ s2 |
1.3m/ s2 |
1.3m/ s2 |
Frequency, Hz |
16 Hz |
18 Hz |
20 Hz |
22 Hz |
24 Hz |
||
Acceleration, m/ s2 |
Direction |
Horizontal |
15m/ s2 |
13.2m/ s2 |
11.2m/ s2 |
9.4m/ s2 |
7.5m/ s2 |
Vertical |
10.5m/ s2 |
9.2m/ s2 |
7.8m/ s2 |
6.6m/ s2 |
5.3m/ s2 |
||
Frequency, Hz |
36 Hz |
40 Hz |
44 Hz |
48 Hz |
50 Hz |
||
Acceleration, m/ s2 |
Direction |
Horizontal |
1.8m/ s2 |
1.8m/ s2 |
1.8m/ s2 |
1.8m/ s2 |
1.8m/ s2 |
Vertical |
1.3m/ s2 |
1.3m/ s2 |
1.3m/ s2 |
1.3m/ s2 |
1.3m/ s2 |
Devices
ammeter M42300, voltmeter M42300, milliammeter M42300, kiloammeter M42300.
kilovoltmeter M42300 in the transport container can withstand without damage shaking
acceleration up to 30m/s2 during transportation with frequency from 80 to 120
beats per minute for 2 hours;
Devices manufactured for use in tropical climates is fungi resistant;
Full range of adjustment proofreader is at least 2% of the entire scale length;
Temperate climate conditions for ammeter M42300, voltmeter M42300, milliammeter
M42300, kiloammeter M42300, kilovoltmeter M42300:
- Temperature - from -5 ° C to +40 ° C;
- Relative humidity - 80% at +25 ° C;
Tropical climate conditions for ammeter M42300, voltmeter M42300, milliammeter
M42300, kiloammeter M42300, kilovoltmeter M42300:
-
Temperature - from -5o ° C to +60 ° C;
- Relative humidity – not more than 100% at +35 ° C;
Vibration resistance devices ammeters M42300, voltmeters M42300, milliammeter M42300, kiloammeters M42300, kilovoltmeters M42300:
- Acceleration - 5m/ s2...30m/ s2;
- Frequency - 10Hz
... 70Hz;
Shock resistance: acceleration 100m/ s2, frequency
10 ... 50 beats per minute;
Devices ammeter M42300,
voltmeter M42300, milliammeter M42300, kiloammeter M42300,
kilovoltmeter M42300 are nonrecoverable, single
channel and single-function products;
Set includes:
- device - 1pc;
- Nuts and washers for device fastening to
the panel and connecting of the
electrical circuit;
- Calibrated wire, if the devices will be uses with interchangeable
shunt (on agreement with the customer) - 1
psc.;
- Additional resistance to voltmeters (10kV
and 15kV) (on agreement with the customer) – 1psc;
- Interchangeable external shunt (on agreement with
the customer) – 1psc;
- Documentation – 1psc.;
- Manuals
for a lot of devices (on agreement with the customer) –
1psc;
Note - External
shunts and additional resistance to ammeters M42300,
voltmeter s M42300, milliammetersM42300, kiloammeters M42300,
kilovoltmeters M42300 are supplied for additional fee;
Devices operation:
- Devices are panel meters of magnetoelectric
system with a magnet
inside;
- Measuring mechanism of ammeters M42300,
voltmeter s M42300, milliammetersM42300, kiloammeters M42300,
kilovoltmeters M42300 consists of a magnetic system (magnetic core). Counting device (scale pointer) and the
movable part in the cores;
Devices are manufactured with a uniform scale, with the zero mark on the edge of within the measuring range. Scale length 60 mm;
Scale highlighting is held by an external source of light through the side windows in device’s cover;
Case parts of ammeters
M42300, voltmeter s M42300, milliammetersM42300, kiloammeters
M42300, kilovoltmeters M42300 are made of plastic
and protect
the measuring mechanism from contamination.
The principle of devices operation
is based on the interaction of the
magnetic field with permanent magnetic
electric shock passing along the devices
winding;
Pointer setting
of ammeters M42300, voltmeter s M42300, milliammetersM42300, kiloammeters M42300,
kilovoltmeters M42300 to zero are
performed by the corrector, located on the cover of devices;
Set up and installation:
- The devices are designed for built in on
vertical or horizontal panels (billboards), made from both magnetic and
non-magnetic materials;
- Devices installation must be made carefully
without distortions. Devices setting up on the panel must be rigid and not
creating additional vibration;
- Devices: ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300, kilovoltmeter
M42300 should be located away from strong fields of magnetic
sources with intensity higher than 0.4 kA/m during installation;
- Devices voltage supply is over 650V
- Device should be verified before the installation on the shield;
- Connection ammeter M42300, voltmeter M42300,
milliammeter M42300, kiloammeter M42300, kilovoltmeter M42300 must be carried out in compliance with the polarity
marked in accordance with the current-carrying rods;
The manufacturer guarantees all technical requirements, if all the conditions are held: storage, transportation and installation;
Photos
If necessary we can take photos of a device from various angles.
Technical Documentation
In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you.
Also I may speak directly with the manufacturer and find out more specific information about this product.
If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
In addition, translation of technical documentation into the customer’s language may be discussed.
Delivery set
On delivering the device will be completely ready for use.
There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
Warranty
Warranty of this item - 12 month.
Before sending a device, all devices are checked whether they comply with all technical specifications.
Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
If necessary, we can send you photos or video with the check-up process.
I ship only fully working devices complying with all parameters.
The warranty for this device is 1 year from the date of shipment from my warehouse.
Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
Within 1 year term we can advise you for free on the device operation.
After-warranty service
After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.
Packaging
Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
A special handle will be made for ease of transportation.
Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
Discount (from-10% to -90%)
I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.
Unused cheap devices with the same specifications, accuracy and durability do not exist.
If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.
I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then
I guarantee to sell you a unit at that cheaper price with additional 10% discount.
Shipping details:
Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
I send goods via AirMailpost.
App. delivery time :
Europe – 7-15 days;
USA, Japan&others – 10-2days (depends on a country).
I will ship in 2-3 business days after payment clearance.
The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
With express delivery you will mostly receive your goods within 3-7 working days.
Payment details:
I expect payment in 4 days after the auction ends.
I accept a PayPal payment as the safest way of payment (preferably).
If you do not have a PayPal account you can pay by wire transfer to my credit card.
Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
(This will be an official purchase on eBay).
Please, tell me if you cannot pay in time, we can always negotiate it.
When purchasing a few items, you’ll save on shipping.
Return policy:
I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
I will refund your costs or send you the other item, as you wish (after I receive the previous item).
Please only serious bidders!