1.Functional Introductions
1.Measurement of Battery percentage and remaining battery AH number.
2.Measurement of DC  bidirectional current.
3.Measurement of DC  bidirectional power.
4.Measurement of DC  bidirectional accumulative electric energy.
5.High voltage alarm flicker function.
6.Low voltage alarm flicker function.
7.High current alarm flicker function.
8.Low electricity alarm flicker function.
9.The function of reach the full voltage (this voltage can be set by youself) automatically fill the battery.
10.Zero current can be cleared.
11.Accumulative energy can be cleared.
12.The backlight can be closed or opened.
13.Store data when power off.
14.Hall sensor isolation type measurement,more safe and reliable, easy to install.
15.Using STN full view LCD screen,clear display.
16.Super wide power supply voltage range: DC5~90V.

 


2.LCD Panel and Key
126
3.Key Use Instructions
  • Backlight Control:
    In standby display, short press “▲”key can turn on or turn off the screen backlight, backlight state power off automatically save
  • Clear Current:
    In standby display, long press “▲”key about three seconds can clear current,(Note:The load must be empty when clear,otherwise it's inaccurate)
  • Clear Electric Energy:
    In standby display,long press “█”key about three seconds can clear electric energy.
  • Setting Parameters:
    In standby display,short press “█”key can switch the menu as follows:
    【1the menu of battery rated capacity setting. 】“AH XXX.X”
    【2】the menu of full power automatically filled voltage “FU XXX.X”
    setting.     【3】the menu of high voltage alarm setting.
    “HU XXX.X”
    【4】the menu of low voltage alarm setting. “LU XXX.X”
    【5】the menu of high current alarm setting. “HA XXX.X”
    (1)In  standby  display, short press █ key,will switch to the menu “AH XXX.X”. Battery  rated  capacity  setting:
    (2)The first digit of the menu parameter will flicker,short press ▲ key
    at this time digit will increasing one.When the button  is not operated within five seconds, it will automatically jump to the next number to flicker.and you short press ▲ key digit will also increasing one.And the like to set up four numbers.
    (3)After set up four numbers ,Long  press █ key about three seconds (Note: it is not short press) and then release the key can save the parameters.When to save success the screen will flicker two times.
    For example:When you want to set the battery rated capacity to be 20AH.You should set this menu parameter of“AH 020.0”,and long  press █ key to save parameter is finish.

     


    (1)In  standby  display, short press █ key,and switch to the menu “FU XXX.X”. The battery is full of the highest electric voltage setting:
    (2)The first digit of the menu parameter will flicker,short press ▲ key at this time digit will increasing one.When the button  is not operated within five seconds, it will automatically jump to the next number to flicker.and you short press ▲ key digit will also increasing one.And the like to set up four numbers.
    (3)After set up four numbers ,Long  press █ key about three seconds (Note: it is not short press) and then release the key can save the parameters.When to save success the screen will flicker two times. (Note: This voltage is suggested to be set to 0.2V less than the Coulomb's voltage  when the battery is full and has not pulled out the charger.)
    And the like you could setting the  parameters of (This three parameters of the factory default is “000.0” ,the factory default is to close this item's alarm function.) “HU XXX.X”“LU XXX.X”“HA XXX.X” Not:

     


    4.Coulommeter Mechanical Size Diagram

     

     


    127 128 129

     

     


    Hall Effect Coulometer Technical Parameter
    Model

     


    PVA100
    PVA200
    PVA400
    Current Test Range

     


    0 ~100A
    0 ~200A
    0 ~400A
    Current Resolution

     


    0.1A
    0.1A
    0.2A
    Power Supply Voltage Range
    DC5 ~90V
    Voltage Test Range
    DC0 ~300V
    Voltage Resolution
    0.1V
    Capacity Test Range
    0 ~999AH
    Power Test Range
    0 ~999KW
    Electric Energy Test Range
    0 ~999KWH
    Measuring Accuracy:
    1%
    Slotting Size Of Panel Installation
    76.0mm * 39.5mm
    Diameter Size Of Sensor Hole
    Φ20mm
    Working Current
    When the backlight is open :10MA.
     When the backlight is closed :4MA.

     

     

     

     


    6.Wiring Instructions
    There are three wires in the head of the table, as follows:  
    【1】 is connected to the battery negative pole. The black wire
    【2】 connection power supply positive pole The Red wire .
    【3】 is connected to the battery positive pole The Yellow wire
    When the measured voltage range is DC5~90V,the red and yellow wires are connected in parallel to the battery positive pole.As follows:

     


    130
    When the measured voltage range is over DC5~90V,we should  look for another power supply for Coulometer.As follows:
    131
    7.Precautions For Use
    【1】The battery discharge ,coulomb shows display positive current.The battery charge ,coulomb shows display negative current. If not,the direction of the sensor is wrong. You show turn the direction of the sensor to another direction.
    【2】The newly installed Coulomb needs to clean up the current at an empty load. 【3】The rated capacity of the battery and the maximum electric voltage of the battery must be set up. The newly installed Coulomb needs to charge the battery to full after setting up the parameters,then residual battery  power can be displayed  normally

     

     

    Package include:

    1pcs meter

    1pcs hall sensor

    1pcs 15cm sensor extension cable

    1pcs 3p power supply cable