Votronic Fresh Water Tank Display S with Tank Electrode 15-50K

Votronic Tank Electrode 15-50K Meets DIN 2001-2 guidelines for requirements for drinking water

Made in Germany by Votronic

Tank Displays

for fresh water, sewage water and feces tanks



Unit Type
Art.-
No.
Operating
Voltage
[V]
Current
Consumption
[mA]

Dimensions
(WxHxD)
[mm]

Assembly
Dimensions
[mm]
Weight
[g]

Fresh Water Tank Display S531112 and 241 - 3047 x 85 x 2029 x 63 x 1825

Mark of conformity:CE, E Test (EMV/Automotive Regulations)
Delivery Scope:Fastening screws, manual, drilling jig

Description

The VOTRONIC tank displays had been designed for precise level measuring, and they are suitable for any tank material and tank size. The units vary in the arrangement of the three-colour display light-emitting diodes at the range ends and in the symbols imprinted on the front panel.

The tank levels are represented in form of a clearly arranged luminous bar with 10 lightemitting diodes in three colours allowing that the tank levels can be read conveniently at a glance. The displays are working continuously, since intermediate results are displayed in variable brightness. Thus, also tendencies can be recognised at once. During refuelling and emptying of the tanks, the continuously raising or dropping display shows a direct image of the instantaneous level allowing complete control of the procedure. Also the continuous operation of the display contributes to this control. At the touch of a button, the display can be switched-on or -off, or it is switched-off automatically after approx. 10 minutes.

The display units are executed as panel version matching to the VOTRONIC modular system. The appearance (identical height 85 mm) is adapted to the other VOTRONIC display units. Of course, it is possible to retrofit a single display in the vehicle. The small dimensions of the front panel and the particularly small mounting depth of only 15 mm allow an installation at almost any location. Thus, storage space, which is located behind, can be used further.

The units are protected against reverse battery and overload and can be easily connected to the unit rear by means of terminal screws. Installation and operating manual, as well as drilling jig for the furniture cutout, are included in the standard delivery scope. These displays are suitable for 12 V and 24 V operation

Depending on the requirements one of the follwing VOTRONIC Measuring Sensors can be used:

  • Tank Electrode 12-24 K
  • Tank Electrode 15-50 K
  • Tank Sensor FL

It is also possible to assign 2 tanks to the display units (such as inside/outside tank, summer/winter operation, auxiliary tank etc.). For switching, separate switches 2xUM with push-on connection are suitable, such as the Switch Panel 16 A S, Art.-Nr. 1289 or Switch Panel 2x16 A S, Art.-Nr. 1291

Former measuring sensors, tank transmitter sets and tank probes are working according to the conductive measuring method (conductivity). Due to the 7-stage measurement, they are no longer suitable for continuous operation at the tank displays.

Measuring Sensors for Plastic or Metal Tanks


Fresh Water - Sewage Water - Feces

Unit Type
Art.-
No.
Operating
Voltage
[V]
Installation Possibility
at the Tank

Tank Height
min.-max.
[cm]





Tank Electrode 15-50 K 554512 and 24Top/Bottom15 - 50




Mark of Conformity:CE, E Test (EMV/Automotive Regulations)
Delivery Scope :Packing Washer, Coupling Ring PG 29, Flexible cord probe, tank wall bushing, stainless steel conductor, fastening screws, Operating Manual

These tank sensors had been designed particularly for level measuring of water and hydrous media (fresh water, sewage water, grey water, industrial water, feces) in metal or plastic tanks. Thus, they are universally applicable. The measuring electrode can be easily shortened to the height of the tank, and the precise “full” adjustment is effected by an adjusting device at the unit. In case of Tank Electrode 12-24 K or 15-50 K also a “dry” adjustment is possible with the help of a scale.

  1. Easy adaptation to the existing tank height
  2. Linear, continuous signal of the level
  3. Suitable for 12 V and 24 V continuous operation
Tank Electrode 12-24 K
Tank Electrode 15-50 K
Stick electrode, can be cut easily to the tank height
Mounting diameter 63 mm (or. PG 29)
flange diameter 46,5 mm
Connection Cable 75 cm



 
Tank-Sensor FL:Flexible cord probe, can be cut easily to the tank height
Only for tanks with cleaning aperture
For plastic tanks: Wall thickness max. 8 mm
Connection by means of terminal screws
 

Accessories

The individual tank displays of the Info Panel Pro can also be operated with 2 tanks (such as inside tank/outside tank, summer/winter operation, auxiliary tank etc.). For switching, separate switches 2x UM are suitable, such as the Switch Panel 16 A S, Art. 1289, or Switch Panel 2x 16 A S, Art. 1291.

Declaration: for Votronic products sold to USA and Canada, Votronic is free from all pretences means all claims arising from product related injuries.