Read the Detailed User Manual, please Copy → billbigsale.com/source/eSB/HOT-A1-00409.pdf

Product Name: AC current sensor module maximum 50A

Product Features

  1. the module dimensions: length 38mm wide 40mmX
  2. the main chip: op amp, transformers
  3. working voltage: DC5V
  4. the output of switch output
  5. the current detection range: AC 50A maximum
  6. the current sense resistor resolution parameter settings can be changed
  7. the critical point set over-current signal is adjustable, set the resolution 0.3A
  8. with fixed mounting holes for easy fixed installation.

Package Included:

FAQ

https://billbigsale.com/source/Sensor/C223-3.jpg

FAQ

  • Question: how to get the product after the judgment is good or bad?

  • Answer: to the module is energized, the power indicator light (red), indicating that module energized normally. Was connected to the load current is measured after testing the voltage to the ground, voltage module can normal current detection. Then the two testing points of to ground voltage was adjusted to below the test voltage, relay work. Normal module. If not pull in that module is damaged, please contact customer service personnel replacement. Test the voltage through the potentiometer adjustment, Shun clockwise, inverse clockwise adjustment is small.

  • Question: how to set the protection point?

  • Answer: in the detection point current protection, measurement and
. Note

Before installing and using this product, we should read the product instructions carefully, and the power supply power supply must not exceed the power supply voltage, and pay attention to the power supply polarity. Do not use under high temperature and high humidity environment. If you have any questions, please contact customer service or technical personnel, to avoid improper operation caused by the module damage.

We also provide more products as below, if you need, contact me with the current range you need.
Maximum detection current selectable: ± 2A / ± 5A / ± 7.5A / ± 20A / ± 30A / ± 35A / ± 60A / ± 75A / ± 100A / ± 150A / ± 200A,
Product model Working voltage Current detection range AC(A) Output mode Connection method

DC 5V DC 12V DC 24 Relay output See 3 (perforation) for
Current
5A 0.3-4.9
10A 0.3-9.5
20A 0.3-19.5
50A 0.5-48
100A 5-80

A s k    Q u e s t i o n:
Please feel free to  A s k  if you have any questions.

↓ Welcome to Combine More Order inside my store or below, I will provide the shipping discount to you.  ↓