Hot Tub Compatible With Ultra Pure 120V/240V Balboa 4 Prong Amp Plug HTCP2805 / 2805



Product Specifications Model EUV3
Spa Volume 350 - 800 gallons
Ozone Output 0.05 gm/hr
Air Draw (scfh) 1 - 4
Electrical Power 120V/240V/60Hz
Size (LxWxH) 10"x4"x3"
Weight 1lb
Lamp Life 9,000 hours
Troubleshooting Guide

Knowledge of electrical applications is required for trouble shooting. Contact a certified electrician if you are unsure of your ability to service the equipment. Improper servicing will void the Ozone generators warranty. If any problems persist, call UltraPure Water Quality for further technical assistance.

 

 
Blue light is not seen through the air hole. 
Check the cord connection and power to the source to ensure power is available. When the UltraPure Automatic Water Cleaner is plugged directly into the pack, the pump system must be running at low speed to provide power to a receptacle. If the lamp has been off and the air temperature is cold, allow for additional time to light or warm to room temperature.  If the unit will not ‘come on’, call your dealer or UltraPure Water Quality Inc. for repair and/or warranty replacement.

 

 
The ¼” clear tubing has water inside. 
Ensure that air will only pass in one direction through the check valve (from flat side to the round, printed side).    Disconnect the tubing and ensure that the check valve is good. Blow water out of the tubing and ensure there is a double loop (Hartford-loop) somewhere in the tubing before it reaches the unit.
             
No suction is being felt from the tubing. 

 

Check for a bubble mist entering the spa water at the jets. Be sure the filter is clean.Check for water in the ¼” clear tubing. Remove and inspect, clean and/or replace.

 


Notes:
 
When the outside temperature falls below 50F (10C), the Ultra Violet Lamp(s) in your UltraPure Ozone Generator may have difficulty starting. The quartz Ozone producing lamp have mercury vapor inside and the cold temperature causes the mercury to condense and make the lamp(s) more difficult to start. This occurs in all Ultra Violet Ozone generators.

Specifications - Air Draw Chart - Testing

             Spa Specifications
Model  EUV3
4 Hours/Day Up to 15,000 USG
Ozone Output 0.035 gm/hr
Current 0.5 Amp
Dimensions (LxWxH 10"x4"x3"
Weight 1lb
Weight is based on 240V units
 
Air Draw Chart
Model Air Flow  (Standard Cubic Feet Per Hour)
  Typical Recommended*
EUV3 1-4 2
*Exceeding the maximum airflow rate decreases the effectiveness of the unit.

Spa Water Testing
To achieve optimal performance from the UltraPure Automatic Water Cleaner, the spa
must be as clean as possible to start with.
The free chlorine or bromine residual should be maintained at all times. Spa may require
a shock treatment after heavy usage. Follow your dealer’s recommendation.

Test Ideal Range
Bromine 4.0 ppm
Free Available Chlorine (FAC) 2.0 ppm
Total Chlorine (TC) Up to 0.5 ppm above FAC reading
pH 7.4 - 7.8 ppm
Total Alkalinity (TA) 100 - 130 ppm
Calcium Hardness (CH) 200 - 250 ppm
Total Dissolved Solids (TDS) 300 - 1200 ppm