Clamp AC Leakage Current Meter AC 600A Leaker Current Meter Data Hold Function
Instruction:
ETCR6600 High Accuracy Clamp Leakage Current Meter is suitable for measuring AC current and leakage current below 600V, range: 0.0mA~600A, CT size: 35mm x 40mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance.
The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by RS232 interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so o
Product Main Function
1. Measurement of AC current, leakage current, Range:AC 0.0mA~600A
2. Data Storage: 99 groups
3. Peak Hold
4. Line Voltage: below 600V
5. CT Size: 35mm x 40mm
Specification:
Power Supply | 9V(6LR61)(not included During the shipping) |
CT Size | 35mmx40mm |
LCD Size | 32mm×15mm |
Range | AC 0.0mA~600A |
Resolution | 0.1mA |
Accuracy | ±1.5%rdg±5dgt(23℃±5℃,below 75%rh) |
Data Storage | 99 groups |
Data Upload Function | Storage data can be uploaded to the computer, save and print |
Automatic Shutdown | 5 Minutes after power on will shutdown automatically without any operation |
Power Consumption | ≤5mA,continuous working 80 hours |
Working Environment | -10℃~50℃;20%rh~80%rh |
Store Environment | -10℃~60℃;Below 70%rh |
Measurement Method | Clamp CT,Non-contact measurement, integration mode |
Frequency | 50Hz、60Hz Automatic Identification |
Peak Hold | Peak value capture and hold function, long press HOLD key display peak value |
Data Hold | Data hold function: "DH" symbol display |
Overflow Display | Exceed measure range overflow function: "OLA" symbol display |
Line Voltage | below 600V circuit test |
Shift | Automatic |
Measurement Time | 0.5 second/times |
Voltage Alarm | When battery voltage lower than 7.2V, the low battery voltage symbol will display |
Insulation Strengh | AC2kV/rms(Between iron core and shell) |
Suitable Safe Standard | IEC1010-1、IEC1010-2-032、Pollution 2、CAT Ⅲ(600V) |
Meter Weight | 250g |
Meter Dimension | 175mm(L)×70mm(W)×38mm(H) |
Packing:
Package | Outer Package | Carton |
Inner Package | Cloth bag | |
Accessory | Meter | 1 PCS |
Communication Cable | 1 PCS | |
Software CD | 1 COPY | |
Cloth bag | 1 PCS | |
Manual | 1 PCS | |
Certificate | 1 PCS | |
Warranty Card | 1 PCS |