Welcome to Bee_studio DescriptionDescription: This multifunction relay control module, designed specifically for a variety of users with different needs, the use of micro—controller as the master unit, preset 18 kinds of functions, and can he based on user needs, customize and add other specific functions. Power relay module using genuine quality, high—voltage power transistor, red, blue signal lights, military-grade double-sided PCB board, cloth hoard to consider a comprehensive, stable performance, can he widely used in a variety of power control types of occasions. The product was isolated power supply industrial power modules, it has a temperature protection, overcurrent protection and short circuit full protection, high and low voltage isolation. work is very stahle. Features: (1) 2015 new version , the module features 18 kinds, to meet the needs of more applications, (2) Increase the supply anti—reverse function, and does not take the wrong power supply is damaged module, (3) The use of top-qua1ity.high—voltage power supply modules, discrete power supply hefore replacing the system more stable and reliahle, (4) There are 0. 1 seconds / 1 second / l in three timing, timing accuracy of 0. 01 seconds, (5) Increase automatic power saving feature, users can independently set. 1. This product is a new digital multifunction 220v LED countdown display time delay relay modules (a total of 18 kinds of functions specific see below). Authentic music of high quality loose—sided PCB power relay military grade material, stable performance and can he widely and various control switch places. 2. Product of the various modes, the delay time can set your own, you can key settings, set up, after the next power—up according to the countdown setting (power—down memory function) . 3. The product is accurate delay error of 0.01% per second, delay of 0.1 seconds —9999 points for each 1 second LED changes, 4. The module is a high level trigger. 5. This wide range of products can he used in many fields, 6. products are working 1ow-Power mode, press the left button to turn off the digital display or begin to show. 7. Product input with optocoupler isolation, enhanced anti-jamming capability, to ensure stability. Module Function: Users can display the key and select the following 18 kinds of functions in one, you can set and save function parameters, you can also view the parameters of the current function of the time parameter sets the minimum 0.1 seconds adjustable accuracy better than 0.01 seconds, with regard to the specific set operating instructions, can be obtained from vendors. Tips: Function 1—8 start at power on their own, functional 9—18 need high pulse signal (high duration shorter than z0ms, the same applies hereinafter) is triggered to start. Function 1: Timing Pick: After power-up. delay T1 time relay pull , T1 between 0.1 seconds —270 hours adjustable, CH1 interfaces to a bigh level pulse signal, repeat the above functions, Function 2: Timing off: when the power , relay pull, delay T1 time , relay off, T1 between 0.1 seconds —270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions, Function 3: Timing pull then off: After power relay to not pull, delay time T1 reaches relay pull, pull T2 time arrives off the relay off, delay time T1 and T2 in 0.1 seconds —270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions, Function 4: Timing off then pull: After power, immediately the relay pull , Relay off after delay time T1 arrival , relay pull after disconnect time T2 arrive , delay time T1 and T2 in 0.1second —270 hour Adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions, Function 5: Infinite loop timing mode 1: After power, relay to not pull, the delay time T1 reaches relay pull, relay off after pull time T2 arrives, and then repeat the above status, the delay time T1 and T2 at 0.1 second—270 hours Adjustable , CH1 interfaces to a high level pulse signal, repeat the above functions, Function 6: Infinite Loop Timing Mode 2: After power, immediately the relay pull , delay time T1 reaches the relay off, disconnecting time T2 arrives relay pull, and then repeat the above status, the delay time T1 and T2 in 0.1 seconds —270 hours adjustable , CH1 interfaces to a high level pulse signal, repeat the above functions, Function 7: Finite loop timing mode 1: Based on the function 6, increasing the number of cycles , this time between T1 and T2 in 0. 1 seconds —9999 seconds adjustable, NX cycles adjustable between 1—9999 times, the interface to CH1 a high level pulse signal, these functions can he re—started, Function 8: Finite loop timing mode 2: Based on the function 6, increasing the number of cycles , this time between T1 and T2 in 0. 1 seconds —9999 seconds adjustahle, NX cycles adjustahle between 1—9999 times, the interface to CH1 a high level pulse signal, these functions can be re—started, Function 9: Latching relay modes: CH1 interfaces to relay a high level pulse signal, the relay pull, to again give a high level pulse signal relay disconnected. Function 10: Trigger relay modes: CH1 interfaces to relay a high signal relay, relay pull, high disappear, relay disconnected. Function 11: Trigger timing pull: After power relay does not act, CH1 interfaces to a high level pulse signal, the delay T1 time relay pull, T1 in adjustahle between 0. 1 seconds —270 hours, Repeat CH1 interfaces to a high level pulse signal, repeat the above functions, Function 12: Trigger timing off After power relay does not act, a high—level interfaces to CH1 pulse signal relay pull, the relay off after delay time T1, T1 between 0. 1 seconds —270 hours adjustable, repeat to CH1 lnterface a high level pulse signal, repeat the above functions, Function 13: Trigger timing pull and then disconnect: After power relay does not act, a high—level interfaces to CH1 pulse signal , delay time T1 arrival relay pull, pull time T2 arrival relay off, the delay time T1 and T2 between 0. 1 seconds—270 hours adjustable, repeat to a high level pulse signal CH1 interfaces, repeat the above functions, Function 14: Trigger timing disconnect and then pull : After power relay does not act, the CH1 interface to a high level pulse signal , immediately pull the relay, the delay time T1 arrive the relay off ; disconnecting time T2 arrive relay pull , delay time between T1 and T2 0. 1 seconds—270 hours adjustahle , repeat the interface to a high level pulse signal CH1, repeat the above function, Function 15: lnfinite loop timing mode 1: After power relay does not act, give a high level pulse signal CH1 interfaces, the delay time T1 reaches relay pull, pull time T2 arrive the relay off , and then repeat the above state, the extension when the time between T1 and T2 0. 1 seconds— 270 hours adjustahle , repeat the interface to a high level pulse signal CH1, the above function can he restarted, Function 16: Infinite Loop Timing Mode 2: After power relay does not act, CH1 interfaces to a high level pulse signal, the relay immediately pull , the relay off after the delay time T1 arrive, delay time T2 arrive relay pull, then Repeat the above state, the delay time between T1 and T2 0. 1 seconds—270 hours adjustahle , repeat the interface to a high level pulse signal CH1, the above function can he restarted, Function 17: Finite loop timing mode 1: based on the function 15 , increasing the number of cycles feature, this time between T1 and T2 in 0. 1 seconds —9999 seconds adjustahle, NX cycles adjustahle hetween 1—9999 times, repeated to CH1 interface to a high pulse signal, you can restart the above functions, Function 18: Finite loop timing mode 2: based on the function 16, increasing the number of cycles feature, this time between T1 and T2 in 0. 1 seconds —9999 seconds adjustahle, NX cycles adjustahle hetween 1—9999 times, repeat to CH1 interface to a high pulse signal, you can restart the above functions, Set Power-countdown set the time range: in working condition, long press UP key, Display —0X (— 01/OZ/03/04/O5), press UP key X scroll, press the Enter key (Enter) to confirm the save. --01:Is 0.01 seconds range (0.01—99. 99 seconds) --02:0.1 second range (0.1—999.9 seconds) --03:1 second gear (1—9999 seconds) --04:1 minute file (1—9999 points) --05:Is hour shift (1—9999 hours) Setup function: (1) long press SET to enter the function selection, display P—0X, (X: l—l8) may press the SET button to select the corresponding function and press Enter to confirm. (2) Press UP / DOWN to add and subtract Tl time, press Enter to confirm. (3) Press UP / DOWN to add and subtract time T2, press Enter to confirm. (4) Press the UP / DOWN to add and subtract NX times, press Enter to confirm. setup is complete, the control panel start working. POower Save Settings: In the process of running the state, long press the Enter key to closing and opening the digital display. Interface: Relay outputs: 3—wire interface, all interfaces are terminals 1, CK: normally open relay interface, the relay pull before the vacant , relay pull after short with COM 2, COM: Common lnterface Relays 3, CB: normally closed relay interface COMl relay shorted before and after the pull—vacant Load capacity: normally open port maximum load capacity: DC 0—30v/l0A, AC 0—2500v/l0A NC port maximum load capacity: DC 0—28v/l0A, AC 0—l25v/l0A Package Include: Relay Switch Module x 1 Payment
Delivery details
Terms of sales
Return
Contact us
|