Features: 1: Product model: 24 functions to meet more application requirements; it can control solenoid valves, water pumps, motors, light strips, etc.
2: Input voltage: DC 5/6/12/24V optional
3: Output power: can control DC or AC load within 5A
4: Time range: 0.01 second to 999 minutes, adjustable
Wiring port description:
1. DC+: Input the positive pole of the DC power supply
2. DC-: Input the negative pole of DC power supply
3. IN+: Positive signal input terminal
4. IN-: negative signal input terminal
5. NO: Relay normally open interface, the relay is suspended before it is closed, and shorted to COM after it is closed
6. COM: common interface of relay
7. NC: Normally closed interface of the relay, the relay is short-connected with COM before it is closed, and it is suspended after being closed
Button trigger: (positive trigger: DC- and in- short-circuit, DC+ and IN+ are connected to the button)
Or: (Negative trigger: DC+ and in+ are short-circuited, DC- and IN- are connected to the button)
Function list:
P-11: Jog (to pull in the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (close the signal relay once, and stop the signal relay again)
P-13: Give the signal, and the relay will automatically stop after closing for A second; the trigger is invalid during the delay period
P-14: Give the signal, the relay will stop automatically for A second; trigger to re-timing during the delay period
P-15: Give the signal, and the relay will stop automatically for A second; during the delay period, the superposition timer will be triggered
P-16: Give the signal, and the relay will stop automatically for A second; trigger reset during the delay
P-17: Give the signal, the relay is closed, the input signal is disconnected, the power will be turned off after A second, and the signal will be output again during the delay period, and the timing will stop
P-18: After power on, the relay will be closed immediately, and power off after a delay of A seconds; until the next power on
P-21: Give the signal, after a delay of A second, the relay is closed
P-22: Give the signal, after more than A second, the relay is closed, the signal disappears, and the relay stops
P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops
P-24: There is a signal. After A second, the relay is closed. After the signal disappears for more than A second, the relay stops.
P-25: There is a signal. After A second, the relay is closed. When there is another signal for more than A second, the relay stops.
P-26: With signal, the relay will stop after closing for A second, and when the signal disappears, the relay will stop after closing again for A second.
P-27: If there is a pulse signal, the relay stops; if there is no pulse signal, the relay will be closed for A second; (the signal continues or the signal disappears is regarded as no pulse signal)
P-28: After power-on, after a delay of A second, the relay is closed until the power is off
P-31: After power on, the relay is closed for A second, disconnected for B second, infinite loop; power off stops
P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop
P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, after a delay of A second, the relay is closed, and the relay is closed after B seconds.
P-35: There is a signal, after a delay of A second, the relay is closed, and the relay is closed after B seconds.
P-36: When there is a signal, the relay will be closed after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped.
P-37: If there is a signal, the relay will stop automatically for A second when it is closed, and then it will count for B seconds after it stops. The signal trigger is invalid within the time A+B
P-38: If there is a signal, the relay will automatically stop when it is closed for A second. After stopping and counting for B seconds, it will automatically stop when it is closed again for A second.
P-41: No action when there is a signal; trigger when the signal disappears; the relay is disconnected after a delay of A time
P-42: When the signal disappears, the relay will work after delaying time A; the working time B ends
P-43: The signal disappears. After the time A exceeds, the relay works; the working time B ends
P-44: After power on, the relay will work for A time and stop for B time; it will automatically stop after cycling C times.
P-45: No action when energized, after signal is given; the relay works for A time, stop for B time; cycle C times and automatically stop; give signal again, execute again
P-46: After giving the signal more than A times, the relay will be closed; keep closed; power off and stop.
P-47: After giving the signal more than A times, the relay will be closed for B seconds and stop
P-48: Within C seconds, after continuously giving the signal more than A times, the relay will be closed for B seconds and stop