Grounding Current Meter Transformer Core Reactor Earth Current Tester 0mA-100A

 

 

Note:Battery not included in the package

Introduction:

Transformer Core Earth Current Tester, can online measure the grounding current and leakage current of transformer core in electrical power systemrange: 0.00mA~100A), The core is made of magnetic shielding material with strong anti-interference ability,  CT size: 80mm x 80mm, can clamp and test Φ80mm cable and grounding wire. or 96mm×4mm flat steel grounding wire. it`s no need to disconnect the tested circuit and can measure the line current. The meter is equipped with a 3.5-inch color touch LCD screen, two operating modes of touch and button, display the magnitude and waveform of the measured current in real time. with alarm critical value setting , alarm indication function, and automatic shutdown function. Normal operation of the transformer core is a single grounding point , if there are two points or more at the same time grounding, the core and the earth will form a current loop, the maximum current up to dozens of amperes, which will cause the core local overheating or even burned. This instrument can find latent faults of transformer as soon as possible, which is one of the main tools to ensure safe operation and normal maintenance of transformer. Mainly used for leakage current testing of the core and clamps of transformer substation, power station as the transformer, electric reactor and other electrical equipment.

The instrument consists of host, current clamp, monitoring software and communication cable.The meter can store 200 groups of data, which can be imported into the computer by USB interface. Monitoring software can online real-time monitoring and historical query functions, dynamic display, waveform indication, alarm value setting and alarm indication, historical data reading, consulting, saving, printing and other functions.

 

Product Main Function

1. Transformer Core Earth Current Test;  Online testinf AC leakage current , currrent ,Frequency.

2. Current Range: 0.00mA~ 100A

3. Frequency: 10Hz~1000Hz

4. Alarm Function: Audible and visual alarm
5. Data Storage : 200 groups

6. Line Voltage : Below AC 600V 

7. CT Size : 80mm×80mm

8. LCD Size : 3.5 inch color touch LCD screen (320dots × 240dots)

 

Specification:

Function

Transformer core earth current test; Online testing of AC leakage current, current, frequency.

 

Power Supply

DC 9V alkaline dry battery LR6 1.5V×6(battery not included)

 

Test Mode

Clamp CT

 

CT Caliber

80mm×80mm( can clamp Φ80mm wire, or 96mm×4mm flat steel grounding wire)

 

Current Range

AC 0.00mA ~100A

 

Resolution

AC0.00mA~9.99mA ; resolution: 0.01mA

AC 10.0mA99.9mAresolution0.1mA

AC 100mA999mAresolution1mA
 AC 1.0A
100.0Aresolution0.1A

Accuracy

±0.5%±5dgt

 

Frequency Range

10HZ1000HZ

 

Display Mode

3.5 inch color touch LCD screen (320dots × 240dots)

 

Operation Mode

Simultaneously have intelligent touch and button control mode

 

Host Dimension

198mm×100mm×45mm

 

CT Size

194mm×145mm×40mm

 

Weight

Host:450g; Current clamp: 780g

 

LCD Size

Display area : 71mm x53mm

 

Electric field  interference

When the external electric field 100A is close to 10mm, about 10mA

 

Sampling Rate

1 times / second

 

Data Storage

200 groups (Power down and replace the battery will not lose the data)

 

Date and Clock

With date and clock setting function

 

Sample Serial Number

With test point serial number setting function

 

Automatic Shutdown

With automatic shutdown or not setting function, default 5 minutes after power on will automatic shutdown.

 

Touch Screen Calibration

With touch screen calibration function

 

USB Interface

With USB interface to import storage data into the computer

 

Alarm Settings

Alarm threshold setting range: 10mA ~ 99.99A

 

Alarm Indication

When the test value exceeds the alarm threshold, the LCD flashes and the buzzer sounds

 

Line Voltage

Below AC 600V circuit measurement

 

Overflow Display

Exceed measure range overflow function: "OL" symbol display

 

Battery Voltage

When the battery voltage lower than 7.2V ± 0.1V, low battery voltage symbol display, and remind to replace the battery

 

Rated Current

Max 180mA

 

Lead Cable Length

Current clamp lead cable length 2M

 

Working Temperature

-1040below 80%rh

 

Storage temperature

-1060 below 70%rh

 

Insulator strength

AC 2kV/rms

 

Suitable Safety Standard

IEC1010-1IEC1010-2-032Pollution2CAT  600V IEC61326(EMC standard)

 

Accessories

Host: 1PCS; Current Clamp: 1PCS; USB communication cable: 1PCS; Software CD: 1COPY; Aluminum case: 1PCS