The bactericidal lamp DRT-125-1 (TU 16-675.013-83) is ultraviolet, discharge, mercury, high pressure, arc, tubular designed for work in plants used in medicine, biology, agriculture Economy.
Attention! Irradiation with bactericidal lamp DRT-125-1, when it is in the field of vision, can cause irreversible damage to the eyes and burns of open parts of the body due to exposure to ultraviolet radiation!
Ignition of the bactericidal lamp DRT-125-1 should occur within 1 minute from the moment the power supply voltage is applied to the lamp.
Re-activation of bactericidal lamp DRT-125-1 is possible only after its cooling, and the time of re-ignition should be not less than 15 minutes.
The bactericidal lamp DRT-125-1 operates at an ambient temperature of +10 to +35 ° C and a relative humidity of 60% at a temperature of +20 ° C.
Specifications:
Lamp bactericidal therapeutic
DRT-125-1 Power supply voltage (V) 220
Current frequency (Hz) 50
Lamp power after 10 hours of burning, nominal (W) 125
Lamp power after 10 hours of burning, not more than (W) 132
Lamp ignition voltage is not more than (V) 198
Ignition time, not more than (min) 1
Voltage on the lamp, nominal (V) 95
Voltage on the lamp, permissible (V) 70-110
The strength of the electric current (A) 1.6
Luminous flux, nominal (lm) 1850
Luminous flux, not less than (lm) 1730
Burning time (h) 1000
Working position is arbitrary
Overall length (mm) 135
Diameter of the bulb (mm) 22
Type capping-less
Operating temperature range (° C) + 10- + 35
Weight not more than (kg) 0,01
Distribution of UV radiation of the bactericidal lamp DRT 125-1 in regions A, B, C with respect to the total radiation power in percentages:
Area A (UVA, UV-A, UV-A), 315-400 nm - not more than 21%
Area B (UVB, UV-B, UV-B), 280-315 nm - not more than 25%
Area C (UVC, UV-C, UV-C), 230-280 nm - not more than 11%
Lamp bactericidal DRT-125-1 is used in various medical equipment:
Therapeutic and disinfecting medical equipment: Apparatus Solnyshko OUFK-01, Quartz-125, Quartz-125-1, Quartz-125-2 (LUX)
Sources of ultraviolet radiation (UV radiation), devices for disinfection of air and premises (irradiators / recirculators)
Chambers of sterility preservation of medical instrument (instrumentation)
Installations for water disinfection
Caution! Bactericidal lamp DRT-125-1 contains mercury! - When installing and replacing the lamp, be careful not to allow its destruction.
In case of destruction of the lamp DRT-125-1, it is necessary to collect the mercury with a rubber pear, and the place where the lamp was broken should be treated with 0.1% acidified solution of potassium permanganate (1.0 g per liter of water with 5 ml of concentrated hydrochloric acid HCl), then Contact the appropriate specialists for demercurization of lamps and premises.