4WE 10 E50/EG24N9K4/M new rexroth 4WE 10 E5X/EG24N9K4/M

Product descrip

4WE 10 E50/EG24N9K4/M new rexroth 4WE 10 E5X/EG24N9K4/M

Your product

4WE 10 E5X/EG24N9K4/M

R901278761

 

Type code

01

02

03

04

05


06

07

08

09

10

11


12

13

14

15

16

17


WE

10


5X

/


E





/






*


01

3 main ports

3

4 main ports

4

02

Directional valve

WE

03

Size 10

10

04

Symbols e. g. C, E, EA, EB, etc.; for the possible version, see Symbols

z. B. C

05

Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions)

5X

06

With spring return

no code

With reinforced compression spring

D

Without spring return

O

Without spring return with detent

OF

07

High-power solenoid, wet-pin, with detachable coil

E

08

Direct voltage 12 V

G12

Direct voltage 24 V

G24

Direct voltage 26 V

G26

Direct voltage 48 V

G48

Nominal voltage 96 V at DC solenoid in operation with AC voltage mains (AC voltage mains 100/110 V - 50/60 Hz with an admissible voltage tolerance of +/- 10 %)

G96

Direct voltage 110 V

G1101)

Direct voltage 125 V

G125

Nominal voltage 180 V at DC solenoid in operation with AC voltage (AC voltage mains 200 V - 50/60 Hz with an admissible voltage tolerance of +/- 10 %)

G180

Nominal voltage 205 V at DC solenoid with operation with AC voltage mains (AC voltage mains 230 V – 50/60 Hz with an admissible voltage tolerance of +/- 10 %)

G205

Direct voltage 220 V

G220

Alternating voltage 100 V

W100R1)

Alternating voltage 110 V

W110R1)

Alternating voltage 120 V

W120R1)

Alternating voltage 200 V

W200R1)

Alternating voltage 230 V

W230R1)

Connection to AC voltage mains via control with rectifier (see table Mating connectors)

2)

Electrical connections and available voltages see Technical data

09

Without manual override

no code

With concealed manual override (standard)

N93)

With concealed manual override and protective cap

5)

N83)

With lockable manual override "mushroom button" (large)

N53; 4)

With manual override "mushroom button" (large), not lockable

N63)

Corrosion resistance(outside)

10

None (valve housing primed)

no code

Improved corrosion protection (240 h salt spray test according to EN ISO 9227) (see also Technical data)

J3

Electrical connection

11

Individual connection

Without mating connector; connector DIN EN 175301-803

K46)

Without mating connector; connector DIN EN 175301-803 (coil with potted-in connector base and sealing element to valve housing (IP67))

K4K6) 7)

Without mating connector, 4-pole with connector M12 x 1 according to IEC 60947-5-2, integrated interference protection circuit and status LED

K72L 6)

Without mating connector; connector AMP Junior-Timer

C4Z6)

Central connection

Cable entry at the cover, with indicator light

DL

Central plug-in connection at the cover, with indicator light (without mating connector); connector according to DIN EN 175201-804

DK6L

Without mating connector; threaded connection 1/2“-14 NPT

DAL

Cable gland at the cover, with indicator light and cable bridge at the ground connection

DJL

Mini-charge connector, 5-pole

DK25L

For further electrical connections and available voltages, see Technical data

Switching time increase

12

Without switching time increase

no code

With switching time increase (only with symbol ".73"; not for version "D" with reinforced compression spring; more information upon request)

A12

13

Without throttle insert

no code

With throttle insert

8; 9);

Port

Throttle Ø in mm mm

0,8 mm

1,0 mm

1,2 mm

P

B08

B10

B12

A

H08

H10

H12

B

R08

R10

R12

A and B

N08

N10

N12

T 10)

X08

X10

X12

Further throttle insert diameters upon request.

Control spool play

14

Standard

no code

Minimum (to be selected in case of reduced leakage → higher level of oil cleanliness recommended)

T06

Increased (to be selected in case of a hydraulic fluid/environment temperature difference >25 K → increased internal leakage)

T12

Seal material

15

NBR seals

M

FKM seals

V

Seals for HFC hydraulic fluids

MH

Low-temperature version

MT

Observe compatibility of seals with hydraulic fluid used.

16

Approval according to CSA C22.2 no. 139-10

CSA

Porting pattern according to ANSI B93.9 (if solenoid "a" is energized, channel P is connected to A)

AN

17

Further details in the plain text

*


1) Only for “central connection” version

2) Only for “individual connection” version

3) The manual override cannot be allocated a safety function. The manual override units may only be used up to a tank pressure of 50 bar.

4) With tank pressures above 50 bar, it cannot be guaranteed that the valve remains in the position switched by the manual override "N5".

5) Protective cap must be removed prior to actuation.

6) Mating connectors, separate order, omitted since accessories data sheet 08006.

7) When the admissible valve performance limit is exceeded, throttle inserts are to be installed (see Performance limits).

8) Not with low-temperature version "MT".

9) When throttle inserts are used in channel T, the pressure in the working ports and in case of connection to the tank chambers must not exceed 210 bar.

Product description

The directional valve type WE is a solenoid-actuated directional spool valve that can be used as electro-magnetic component. It controls the start, stop and direction of a flow.

The directional valve basically consists of housing (1), one or two electronic solenoids (2), control spool (3), and the return springs (4).

In the de-energized condition, the control spool (3) is held in the central position or in the initial position by the return springs (4) (except for version "O").

If the wet-pin electronic solenoid (2) is energized, the control spool (3) moves out of its rest position into the required end position. In this way, the required direction of flow according to the selected symbol is released.

After the electronic solenoid (2) has been switched off, the control spool (3) is pushed back into its central position or into its initial position (except for valves with "OF" detent and valves without type "O" spring).

A manual override (6) allows for the manual switching of the valve without solenoid energization.

To ensure proper functioning, make sure that the pressure chamber of the solenoid is filled with oil.

Type .WE 10 E…

3

Throttle insert "B.."

Using a throttle insert (7) in channels P, A, B or T, the flow resistance at the valve can be increased. Its use is required when, due to prevailing operating conditions, flows occur during the switching processes, which exceed the performance limit of the valve.

2

Without spring return “O” (only possible with symbols A, C and D)

This version is a directional valve with 2 spool positions and 2 electronic solenoids without detent. The valve without spring return at the control spool (3) does not have a defined basic position in the de-energized condition.

Without spring return with detent “OF” (only possible with symbols A, C and D)

This version is a directional valve with 2 spool positions and 2 electronic solenoids with detent. The detents are used to lock the control spool (3) in the relevant spool position. During operation, continuous application of current to the electronic solenoid can thus be omitted which contributes to energy-efficient operation.

Notice!

Pressure peaks in the tank line to two or several valves can result in unwanted movements of the control spool in the case of valves with detent! We therefore recommend that separate return lines be provided or a check valve installed in the tank line.

Type .WE 10 ../OF…

1

Technical data

For applications outside these parameters, please consult us!

general

Size

10

Type


Einzelanschluss Zentralanschluss

Weight

Valve with one solenoid

kg

3.9 4

Valve with two solenoids

kg

5.5 5.6

Installation position


any 1)

Ambient temperature range

NBR seals

°C

-20 … +70

FKM seals

°C

-15 … +70

HFC hydraulic fluid

°C

-20 … +50 2)

Low-temperature version

°C

-40 … +50

Storage temperature range

°C

-20 … +50

MTTFd values according to EN ISO 13849

yrs

300 3)
1) With suspended installation, higher sensitivity to contamination. Horizontal installation is recommended.
2) For the use at low temperatures, see Project planning information
3) For further details, see data sheet 08012

hydraulic

Size

10

Maximum operating pressure

Port P

bar

350

Port A

bar

350

Port B

bar

350

Port T

bar

210 1)

Maximum flow

l/min

160

Flow cross-section (spool position 0)

Symbol Q


approx. 6 % of nominal cross-section

Symbol W


approx. 3 % of nominal cross-section

Hydraulic fluid


see table

Hydraulic fluid temperature range 2)

NBR seals

°C

-20 … +80

FKM seals

°C

-15 … +80 2)

HFC hydraulic fluid

°C

-20 … +50 2)

Low-temperature version

°C

-40 … +50 2)

Viscosity range

mm²/s

2,8 … 500

Maximum admissible degree of contamination of the hydraulic fluid 3)


Class 20/18/15 according to ISO 4406 (c)
1) With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure.
2) at the valve working ports of the valve
3) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

 


Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM

DIN 51524

90220

Bio-degradable

Insoluble in water

HETG

NBR, FKM

ISO 15380

90221

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Containing water

Water-free

HFDU, HFDR

FKM

ISO 12922

90222

Containing water

HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620 )

NBR

ISO 12922

90223


electrical

Voltage type


Direct voltage AC voltage

Nominal voltage according to VDE 0580

V


12
24
26
48
96
110
125
180
205
220
100
110
120
200
230 1)

Voltage tolerance (nominal voltage)

%


± 10

Nominal power according to VDE 0580

W


40 2)

Duty cycle

%


100 3)

Switching time

ON (pressure change 5 %)

ms


60 … 104 4)

ON (pressure change 95 %)

ms


90 … 165 4)

OFF (pressure change 5 %)

ms


12 … 50 5) 230 … 330 5)

OFF (pressure change 95 %)

ms


48 … 104 5) 250 … 360 5)

Switching time according to ISO 6403

ON

ms


45 … 60 6)

OFF

ms


20 … 30 6) 250 … 360 6)

Maximum switching frequency

1/h


15000 7200

Maximum surface temperature of the coil

°C


140 7)

Insulation class VDE 0580



F

Electrical fuse protection



Every solenoid must be protected individually using a suitable fuse with tripping characteristics K (inductive loads). The valve must be installed on a surface that is included in the equipotential bonding.

Protective earthing conductor and screening



see connector pin assignment (CE-compliant installation)

Conformity



CE according to Low-Voltage Directive 2006/95/EC tested according to DIN EN 60204-1 (VDE0113-1): 2010-05 and DIN VDE 0580: 2000-07
1) Possible with central connection or via rectifier. Mating connectors with rectifier (separate order). Rectifiers must comply with the relevant standards as well as the coil performance data! With a central connection, the rectifier is on the board.
2) Reduction of the nominal power by approx. 40 % when using a 24 V coil with connector switching amplifier type VT-SSBA1-PWM-1X/V002/5 (separate order, material no. R901265633, see data sheet 30362)
3) Operating mode according to VDE 0580
4) Measured with flow, 80 % performance limit and horizontal installation position. Not with symbols A, B and .73. Reduction of the switching time by approx. 50 % when using a 12 V coil with connector switching amplifier type VT-SSBA1-PWM-1X/V001/5 (separate order, material no. R901265633, see data sheet 30362)
5) Measured with flow, 80% performance limit and horizontal installation position.
6) Measured without flow
7) Surface temperature > 50 °C, provide contact protection.

 

Notices!

The solenoid coils must not be painted.
Actuation of the manual override is only possible up to a tank pressure of approx. 50 bar. Avoid damage to the bore of the manual override! (Special tool for actuation, separate order, material no. R900024943). When the manual override is blocked, actuation of the opposite solenoid must be ruled out!
The simultaneous actuation of 2 solenoids of one valve must be ruled out!
Use cables that are approved for a working temperature above 105 °C.
Valves with individual connection and a supply voltage of 12 V or 24 V can be operated with twice the voltage to reduce the switching time. For this purpose, the voltage has to be reduced to the nominal valve voltage after 100 ms by means of pulse width modulation. The maximum admissible switching frequency is 3 1 /s.
Due to possible overload of the board, valves with central connection must not be operated with twice the voltage.

If the standard environmental conditions according to VDE 0580 cannot be provided, the valve must be especially protected!

Diagrams/characteristic curves

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qv characteristic curves

55555

55565

56546765

Symbol

Direction of flow

P –A

P – B

A – T

B – T

A; B

6

6

A73, B73

23

23

C

1

2

5

7

D

2

2

5

7

D73

25

26

26

27

E

17

16

19

21

E67

4

4

11

24

E73

17

18

21

21

F

2

3

22

23

G

4

4

24

24

G73

18

18

24

24

H

14

14

20

21

H73

14

14

6

9

J

3

3

9

11

J73

22

21

23

24

L

3

3

9

9

L73

22

10

11

24

M

14

14

6

8

P

17

14

20

23

Q

16

17

4

8

R

18

21

18

24

R73

24

24

23

24

T

18

4

10

24

U

3

3

6

11

U10

upon request

U73

22

22

23

24

V

17

17

18

20

W

upon request

X7

upon request

X34

upon request

Y

17

16

18

21

Y11

3

2

4

9

Y73

26

26

26

28


Central position:

Symbol

Direction of flow

P – A

P – B

B – T

A – T

P – T

H

12

12

13

13

15


Performance limits (measured with HLP46, ϑOil = 40 ±5 °C)

Notice!

The specified performance limits are valid for use with two directions of flow (e. g. from P to A and simultaneous return flow from B to T).

Due to the flow forces acting within the valves, the admissible performance limit may be considerably lower with only one direction of flow (e. g. from P to A while port B is blocked)!

In such use cases, please consult us!

The performance limit was determined when the solenoids were at operating temperature, at 10 % undervoltage and without tank preloading.

Spring side

1

Characteristic curve

Symbol

1

L

2

A

3

B

4

Y

5

E73, Q

6

F

7

G73

8

M; V

9

P

10

A73

11

H73


Solenoid side

3

2

Characteristic curve

Symbol

1

L

12

A/O

13

J

14

H

15

D73

16

B73

17

Y11

18

C; D; E73

19

E67

20

G


Performance limits (measured with HLP46, ϑOil = 40 ±5 °C)

Notice!

The specified performance limits are valid for use with two directions of flow (e. g. from P to A and simultaneous return flow from B to T).

Due to the flow forces acting within the valves, the admissible performance limit may be considerably lower with only one direction of flow (e. g. from P to A while port B is blocked)!

In such use cases, please consult us!

The performance limit was determined when the solenoids were at operating temperature, at 10 % undervoltage and without tank preloading.

Solenoid side

55

4

Characteristic curve

Symbol

21

A; B

22

G73

23

F; L73

24

E

25

C/O; D/O

26

J73

27

U


On solenoid side

5555

Solenoid side

5

Characteristic curve

Symbol

28

Q

29

V

30

P

31

R

32

R73

33

T

34

U73

35

Y73


Symbols/Circuit diagrams

111

Notices!

Representation according to DIN ISO 1219-1.

Hydraulic interim positions are shown by dashes.

11111
1) Example:
● Symbol E with spool position “a” ordering code ..EA..
● Symbol E with spool position “b” ordering code ..EB..
2) For the flow cross-section refer to the Technical data

Notices!

Representation according to DIN ISO 1219-1.

Hydraulic interim positions are shown by dashes.

Other symbols upon request.

Electrical connection

Over-current fuse and switch-off voltage peaks

Maximum admissible overvoltages according to DIN EN 60664-1:2008-01 (VDE 0110-1) (overvoltage category II):

Electrical connection

1)

Nominal voltagein V

Rated currentin A

Maximum switch-off overvoltage to be energized in V

2)

K4, K4K, DAL, D6KL, DL

12

3,72

500

K4, K4K, K72L, DAL, D6KL, DL, DJL, DK25L

24

1,74

500

K4, C4Z

26

1,70

500

K4

48

0,57

500

K4, DAL, D6KL, DL, DK25L

96

0,47

500

D6KL, DL, DJL

110

0,41

500

K4

125

0,22

500

K4, C4Z

180

0,28

500

K4, DAL, D6KL, DL

205

0,22

500

K4, DAL, D6KL, DL

220

0,21

500

1) Interference protection circuit integrated
2) To be ensured by user circuitry

Notice!

When solenoid coils are switched off, voltage peaks result which may cause faults or damage in the connected control electronics. We therefore recommend limiting them to 2 x nominal voltage by means of an interference protection circuit. It must be noted that a diode switched in an antiparallel form extends the switching off time.

Electrical connections and coil connection combinations

Ordering code connector

Top view

Circuit diagram

Pin

Connections, assignment

3-pole connector (2+PE) according to DIN EN 175301-803 (IP65)

K4, K4K 2)

54645645

54754

1

Solenoid coil, polarity-independent

2

Earthed

Earthing

4-pole connector according to IEC 60947-5-2, M12x1 with suppressor diode, only 24 V DC, integrated interference protection circuit and status LED

K72L

25234

342323532

1

Internal bridge

2

3

Solenoid coil GND

4

Solenoid coil 24 V DC supply voltage

5

Without function

2-pole connector, type AMP Junior-Timer, rotated by 90° relative to valve axis

C4Z

111

23232

1

Solenoid coil, polarity-independent

2

1) M3, tightening torque maximum MA max = 0.5 Nm
2) Coil with potted-in connector base and sealing element to valve housing (IP67)

Electrical connections and coil connection combinations

Ordering code connector

Top view

Circuit diagram

Pin

Connections, assignment

Cable gland at the cover, with indicator light (terminal area 6 … 12 mm)

DL

324234234

2342323

1+

Valve solenoid "a"

2)

Cable gland at the cover, with indicator light and cable bridge at the ground connection (terminal area 6 … 12 mm)

DJL

2-

43534543

23432

3+

Valve solenoid "b"

2)

Without mating connector; threaded connection 1/2“-14 NPT (terminal area 6 … 12 mm)

DAL

4-

Earthed

Earthing

Central connection at the cover, with indicator light (without mating connector) with connector according to DIN EN 175201-804

DK6L

5753452

2342342354

1

Valve solenoid "a"

2

3

Valve solenoid "b"

4

5

not assigned

6

Earthed

Earthing

Mini-change connector, 5-pole according to ANSI/B93.55M-1981

DK25L

235434534

54645645756

1

Valve solenoid "a"

5

2

Valve solenoid "b"

4

3

Earthing


For details and more mating connectors see data sheet 08006



Port

Valve side

Color

Material no.

Without circuitry

With indicator light

12 ... 240 V

With rectifier

12 ... 240 V

With indicator light and Zener diode suppression circuit

24 V

M16 x 1,5

a

gray

R901017010

a/b

black

R901017011

R901017022

R901017025

R901017026

1/2″ NPT
(Pg16)

a

red/brown

R900004823

a/b

black

R900011039

R900057453

R900842566


Energy savings and fast switching

1)​

Details see data sheet 30362


Material no.

Type VT-SSBA1-PWM-1X/V001/5 as fast switching amplifier (switching time reduction by approx. 50 %)

2)

Type VT-SSBA1-PWM-1X/V002/5 for energy reduction (energy saving by approx. 40 %)

3)

a/b

black

R901265633

R901290194

1) Groove with symbols C, D, E, E67, J, J2, Y and Y11; not for version reinforced compression spring “D”
2) Only for version “G12” and “K4/K4K”
3) Only for version “G24” and “K4/K4K”

Dimensions

Individual connection

234235354

1.1

Solenoid “a”

1.2

Solenoid “b”

5.1

Mating connector without circuitry for connector "K4" (separate order, see mating connectors and data sheet 08006)

5.2

Mating connector without circuitry for connector "K4K" (separate order, see data sheet 08006)

5.3

Mating connector angled with M12x1 plug-in connection and status LED for connector "K72L" (separate order, see data sheet 08006)

5.4

Double mating connector without/with circuitry for connector "K4" (separate order, see data sheet 08006)

5.5

Mating connector (AMP Junior Timer) for connector "C4Z" (separate order, see data sheet 08006)

6

Mating connector without circuitry for connector "K4" (separate order, see mating connectors and data sheet 08006)

9

Name plate

10

Identical seal rings for ports A, B, P, TA, TB

11.1

Plug screw for valves with one solenoid on B side

11.2

Plug screw for valves with one solenoid on A side

12

Space required to remove the mating connector/angled socket

13

Space required to remove the coil

14

Mounting nut, tightening torque MA = 14.5±1.5  Nm

15

Porting pattern according to ISO 4401-05-04-0-05 and NFPA T3.5.1 R2-2002 D05

16

Connection TB can only be used in connection with separately produced bore.


Notice!

Deviating from ISO 4401, port T is referred to as TA and port T1 is referred to as TB in this data sheet.
The dimensions are nominal dimensions which are subject to tolerances.

Central connection

234351211

7.1

Cable gland Pg 16 "DL" (terminal area 6 … 12 mm); lock nut, tightening torque MA = 3.3 Nm±10 %

7.2

Central connection box "DAL“ 1/2“ NPT, tightening torque MA = 5 Nm ± 10 %; sealing by sealant

8.1

Mating connector for connector "DK6L” (separate order, material no. R900002803, see data sheet 08006)

8.2

Mini-change connector, 5-pole for connector "DK25L" (separate order, material no. R900057631)

12

Space required to remove the mating connector/angled socket

14

Mounting nut, tightening torque MA = 14.5±1.5  Nm

15

Porting pattern according to ISO 4401-05-04-0-05 and NFPA T3.5.1 R2-2002 D05

16

Connection TB can only be used in connection with separately produced bore.

17

CoverNotice: The valve may only be operated with properly mounted cover! Tightening torque of the cover screws MA = 1.0 Nm ± 10 %.Prior to opening the frame, it must be ensured that the valve has no voltage!


Special points with version "DAL" and "DL"

Version "DL" is only suitable for permanently installed cables. Lines must be routed in a pull-relieved manner!
Minimum line cross-section 0.75 mm2
With a maximum line cross-section of 1.5 mm2, the wire end ferrules must be crimped to a maximum cross-section of 1.5 x 2 using appropriate tools to ensure they fit into the printed circuit board terminals.
Before crimping, at least 11 mm of the cables have to be stripped.
For the line cross-section, wire end ferrules according to DIN 46228-1 with a minimum length of 10 mm are to be used.
For the earthing connection, ring cable lugs according to DIN 46234-4-1 are to be used, tightening torque MA = 1.75 Nm ± 10 %

Notice!

The dimensions are nominal dimensions which are subject to tolerances.

Manual override

12233

2

Version without and with concealed manual override "N9" (standard)

3

Version with concealed manual override and protective cap "N8". (The protective cap must be removed prior to actuation.)

4

Version with manual override "N5" and “N6


Notice!

The dimensions are nominal dimensions which are subject to tolerances.

Subplates according to data sheet 45054 (separate order)

G 66/01 (G3/8)

G 67/01 (G1/2)

G 534/01 (G3/4)

G 66/12 (SAE-6; 9/16-18)1)

G 67/12 (SAE-8; 3/4-16)1)

G 534/12 (SAE-12; 1-1/16-12)1)

1) Upon request

Valve mounting screws (separate order)

4 hexagon socket head cap screws, metric

ISO 4762 - M6 x 40 - 10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 to 0.14);

tightening torque MA = 12.5 Nm ± 10 %,

material no. R913000058

or

4 hexagon socket head cap screws

ISO 4762 - M6 x 40 - 10.9 (self procurement)

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 15.5 Nm ± 10 %

4 hexagon socket head cap screws UNC

1/4-20 UNC x 1-1/2″ ASTM-A574

(friction coefficientμtotal = 0.19 to 0.24);

Tightening torque MA = 25 Nm ± 15 %,

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 19 Nm ± 10 %,

material no. R978800710

With different friction coefficients, the tightening torques are to be adjusted accordingly!

Project planning information

Port

Pressure

Temperature range in °C

– P, A, B, T

static 100 bar

–40 … –35

– P, A, B

dynamic from 100 bar to 350 barin linear form as a function of the temperature

–35 … –30

– T

dynamic from 100 bar to 210 bar in linear form as a function of the temperature

–35 … –30

– P, A, B, T

Maximum operating pressure

–30 … +50


Accessories


32443534
  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

3423


  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

32433333333

  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

23423432

  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

346432
  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

436546545

  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

534

  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

 

 

 

SHIPPING
Thanks for your bid.

dian1 Item will be shipped from Hong Kong post on the 48 hours after your full payment has been received. 

dian1!!Rate the seller on the time it took to mail the item, not the time it took you to receive the item!! See the ebay policy here

dian1 Delivery time:
----By Airmail: Generally, about 2-3 weeks to UK, USA, AU. 

delivery rate

PAYMENT

Only through PayPal

Warranty & Returns
Return & Refund
dian1Refund or replacement request is available only the requests within 1 week after parcel received & returning the item as the same condition as received.



dian1Please contact us to request a return authorization. Your name, auction number, and reason for return should be included in the email. All items returned must contain all original packaging materials.

dian1Please repack the item carefully. Items returned will be tested and a new replacement will be shipped to the buyer immediately when found defective. In the event that a suitable replacement is not available then a refund will be issued. Shipping, handling and insurance fees are non refundable.

dian1If the item is found non-defective, the item will be sent back to the buyer at buyer's expense. Items returned without RMA number will be refused and returned to the sender. Buyer is responsible for All Return Postage and Shipping Charges. Buyer is responsible for additional shipping costs for items that are returned refused and/or undeliverable. We do not accept any returns without an authorization number on the box or label it is being returned in.
CONTACT US

We live for the moments that we can make you happy—that's the truth!

Most of our business occurs through the internet. However, we know that there are times when you need to communicate with a person. Our customer service staff is here to help you. You can contact us in the way that works best for you.


ABOUT US
hk-industrial-supplus is a high-tech enterprise engaged in advanced electro-hydraulic control technology, with nearly two decades of professional experience. hk-industrial-supplus has always been following closely the development of the world's hydraulic technology, especially that of high-tech components such as digital proportional valves and servo valves, and that of the design of hydraulic system, etc..

To ensure our customers the most reliable technical solutions and guaranteed services, hk-industrial-supplus has organized many official visits to major foreign companies well-known in hydraulics industry, taking technical training courses and learning their modern management philosophy. Long time of contacting, learning and communicating have helped hk-industrial-supplus and these companies establish deep cooperations in such respects as brand promoting, product delivery and technical consultations.

Thanks to so many years of technical experience and skills, hk-industrial-supplus can provide the customers with the most reliable and cost-effective solutions, as well as quality hydraulic components with foreign origin.

hk-industrial-supplus mainly deal with the following businesses:
—Distributing Atos, Bosch Rexroth, Parker, Eaton Vickers, Hydac, etc.
—Design and manufacturing hydraulic control systems (especially proportional and servo systems) and test benches;
—Providing electronic amplifiers and axis controllers and necessary solutions;?

—Supplying components for special hydraulic industries (super-high pressure, extreme temperatures, special fluids, etc.);

—Repairing piston pumps and proportional valves;

"Hydro-power in Need, hk-industrial-supplus on Hand".

Choosing hk-industrial-supplus means the selection of best quality, guaranteed service, competitive prices and on-time delivery.

Our working time:
Hong Kong time :Monday to Friday 9:00 am to 4:30 pm.
We do not work holidays in Hong Kong.
if you send email to us,In our working hours will be resumed within 48 hours.

If you we are not satisfied with the product or service ,please contact me and don't give us negative or natural feedback,We must give you a satisfactory solution.

Feedback & DSRs (Detailed Seller Ratings).
We depend on our eBay reputation and customer satisfaction to succeed.Therefore, Your feedback and DSRs are extremely importantto us as better DSR scores affect our search placement on eBay.
We would like to earn your good feedback and 5 star DSR rating. Your action will help us offer our milk and bread . If we have not given you reason enough for 5-star grades on each DSR then please let us know how we can earn your 5-star rating before submitting yourscores!

Copyright © hk-industrial-supplus. All rights reserved.
DataCaciques