AUTOOL LM120+ is an auxiliary instrument for the installation,testing and maintenance of refrigeration equipment such as air conditioners and cold storage.The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout,multi-unit switching, multi-mode function and built-in refrigerant database.
 
Double pressure test, double temperature test
Digital reading, multi-unit switching
Large-size LCD display, LCD backlight support
Calculate the degree of subcooling and superheating
Test the percentage of vacuum measurement; pressure leak measurement, leak time speed record  
Long-life valve switch, 1/4 inch standard interface design
Built-in 32-bit digital processing unit and high-precision data acquisition unit
Built-in 89 kinds of refrigerant pressure-evaporation temperature database

AUTOOL LM120+ Refrigeration Digital Manifold HVAC Gauges Features
1. [Evaporation Pressure&Tempe test]: The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.(The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.)
 
2. [Condensing Pressure&Temp Test]: The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. (The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do.)
 
3. [High/Low-pressure temperature test]: The temperature of the AUTOOL LM120/LM120+ Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system.
 
4. [Pressure leakage test]: Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.
 
5.[Type Setting&Observable window]: AUTOOL LM120/LM120+ Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.
 
6.[Smart Digital Display]: The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.
 
7.[Three Years Warranty, Lifetime Maintenance]: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years. For any needs, you are warmly welcomed to contact us and we will get back to you ASAP within 24 hours.ght.

Product specifications:

Pressure test: gauge pressure

Pressure test unit: Kpa; Mpa; bar; inHg; PSI.

Pressure test range: 0 Kpa – 6000 Kpa

Pressure test resolution: 1 Kpa

Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt

Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)

Vacuum test: relative vacuum

Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.

Vacuum test range: -101 Kpa – 0 Kpa

Vacuum test resolution: 1 Kpa

Temperature test unit: °C (Celsius), °F (Fahrenheit)

Temperature test range: -40°C–150°C (-40°F–302°F)

Temperature test resolution:

0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)

0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)

Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt

Built-in 89 kinds of refrigerant NIST: According to American NIST standard

Power Supply: 4 X 1.5V (SIZE.AA / LR6)  Battery not include

Dimensions: 170*110*50mm weight: 950g

  • Question 1: How to verify the accuracy of the temperature?
  • Answer: The temperature measured by the gauge is allowed to deviate by 3% from the actual temperature. There is a simple way to verify the accuracy of the temperature: Take out the black wire on the temperature clamp and put it in the boiling water. If the temperature is 100 degrees Celsius or the error is plus or minus 3%, it is normal. NOTE: Please pay attention to temperature unit conversion between Celsius/Fahrenheit.
  • Question 2: Why does the pressure value fluctuate slightly? Is it a leak or is the data inaccurate?
  • Answer: According to the current level of hardware processing in the industry, it is difficult to achieve a 100% completely sealed valve on the market. The sealing degree of our guage hardware can only reach 99%. But these slight leaks will not affect the use.
  • Question 3: Does this gauge have a micron reading function?
  • Answer: No, the accuracy of this refrigerant manifold gauge can only reach the accuracy equivalent to this unit: -101 Kpa-0 Kpa.
Compatible with 89 Kinds of Refrigerants:
R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R13 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B R407C R407D R407E R408A R409A R41 R410A R410B R411A R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A R425A R426A R427A R428A R50 R500 R501 R502 R503 R504 R507A R508A R508B R509A R600 R600A R717 R744(Co2) R1234
 
Note: This pressure guage will read random numbers when it is powered on. You must press the ZERO key to clear the numbers after you power it on, and then you can use it normally.
Packing list:
1x Refrigerantion Digital Manifold Gauge
1x User Manual (in English)
2x Temperature Clip
3x Test Pipe
1x Suitcase
Battery not include
  
  
PushAuction