AUTOOL LM120+ Intelligent Automotive Digital Refrigerant Manifold Gauge,This product can be used as an auxiliary measuring instrument for the installation, testing and maintenance of automotive air conditioning and other refrigeration equipment. It is characterized by dual-pressure test, dual-temperature test, digital display, digital display, multi-unit conversion, multi-mode function, refrigerant parameter database and other features. It is committed to become a professional measuring equipment for maintenance and debugging of air conditioning and refrigeration systems.

Evaporation Pressure&Tempe test
The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.(The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.)
Condensing Pressure&Temp Test
 
The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. (The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do.)
High/Low-pressure temperature test
The temperature of the AUTOOL LM120+ Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system.
Pressure leakage test
Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.
Type Setting&Observable window
AUTOOL LM120+ Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.
Smart Digital Display
The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.
Compatible with 89 Kinds of Refrigerants:
R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R13 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B R407C R407D R407E R408A R409A R41 R410A R410B R411A R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A R425A R426A R427A R428A R50 R500 R501 R502 R503 R504 R507A R508A R508B R509A R600 R600A R717 R744(Co2) R1234
 
Note:This pressure guage will read random numbers when it is powered on. You must press the ZERO key to clear the numbers after you power it on, and then you can use it normally.
Product specifications
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
 
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
 
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include
Dimensions: 170*110*50mm weight: 950g
 
Packing list:
1x Refrigerantion Digital Manifold Gauge
1x User Manual (in English)
2x Temperature Clip
3x Test Pipe
Battery not include
 
EC/EN61010-1 safety standards for design and production.
1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
  
  
PushAuction