Four very clean and working mass flow controllers from Porter, Model 201-DKASVBCP. 1000PSI max. press. N2 gas, 120 ML/MIN., 1/8" compression fitting ports.
Temperature Coefficent (per SEMI E18-91 Zero Effect and Span Effect): ±0.05% full scale / °C of zero
±0.05% of reading/ °C of span
Mounting Orientation: Attitude insensitive
Warm-up Time: 10 minutes
External Electrical Connector: Nine (9)- pin Dconnector
Weight (approximate): 1.2 lbs
Power Supply Requirements: (Current consumption <250 mAdc):
Voltage output models: +12 (±5%) (0-5 Vdc & 1-5 Vdc flow signal outputs only) or +15 (±10%) Vdc
Current loop models: +15 (±5%) or +24 (±15%) Vdc
Setpoint Input/Flow Signal Output: 0-5 Vdc/0-5 Vdc (2K ohm minimum load resistance)
0-10 Vdc/0-10 Vdc (3K ohm minimum load resistance) 1-5 Vdc/1-5 Vdc (2K ohm minimum load
resistance) 4-20 mAdc/4-20mAdc (refer to load resistance values below)
1-5 Vdc/4-20 mAdc (refer to load resistance values below) Load resistance values for 4-20 mAsc
flow signal output: 0-450 ohm for 6.5-15 Vdc
loop supply voltage 200-750 ohm for 15-30 Vdc loop supply voltage
Model 201 Mass Flow Instruments SPECIFICATIONS:
Flow Capacity: Any Flow range from 0-5 SCCM to 0-10 SLPM (nitrogen equivalent).
Response Time (per SEMI E17-91 Settling Time): 1 to 2 Seconds
Accuracy and Linearity: ±1% full scale
Repeatability: Within ±0.2% full scale at any constant temperature within operating temperature range
Rangeability (Control Range): 50; 1 (2%-100% full scale) (accuracy and control)
Ambient and Operating Temperature Range: 80°F / 25°C
Maximum Operating Pressure: 1000 PSIG