Product Name: DC 12V 12ch Digital IO UART RS485 Relay Module Modbus RTU DIN35 C45 Rail Box for PLC PTZ 
 
 
 
Package inlcuded:
  1PCS DC 12V 12 Input & 12 Output RS485 Relay Module
 
 
Description:
  
1: DC 12V (12V Version), 
 
2: Standby current (all relays closed) 14MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 149MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 226MA
 
3 12 photoelectric isolation Input ports (NPN  low level active ), the input and output relationship can be set to associated (default) and non-associated through commands.  
 
4: ''open'' ''close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' ''''Interlock between two channels'' 7 Commands
 
5: MODBUS RTU command, Support 03 06 16 function code
 
6: Under the ''Delay'' command ,the maximum delay is 255 seconds;
 
7 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter; 
 
8 Under the MODBUS command mode, it can support up to 64 devices in parallel
 
9 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
 
10  Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
11 Weight: 190g(Only PCB Board);318g(with Din Rail Box)
12 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
  
 
For more information, please contact me
 
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 180 mm PCB boards
Net weight: 128g
Installation: DIN35 and C45 rail
 
 
Application
 
PLC IO expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
Configuration Software
 
Typical applications:

1 The dial switch (slave address) is invalid and can only control one module at a time.

 


MODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control

 

 

 

Wiring Diagram:

 

1 DC 12V/24 control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V/24V equipment

 
 
 
 
2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V/24V load, need another DC 12V/24V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen