NOTE: 02 Sensor needs to be replaced.
Specifications: | Bacharach 0024-8512 Fyrite InTech Residential Combustion Analyzer |
Measurement Ranges | |
Ambient Temperature | 23° F to 113° F (-5° C to 45° C) |
Flue Gas Temperature | -4° F to 1,202° F (-20° C to 650° C) |
Oxygen (O2) | 0.0% to 20.9% |
Carbon Monoxide (CO) | 0 - 2,000 ppm |
Calculated Ranges | |
Combustion Efficiency | 0.1 to 100% |
Carbon Dioxide (CO2) | 0.1 to a fuel dependent maximum (in %) |
Excess Air | 0 to 250% |
Selectable Fuels | 6 pre-programmed: Natural Gas, Oil #2, Oil #6, Kerosene, B5, and propane/LPG (10 fuels available with Siegert version) |
Data Capability | Up to 10 complete records, internal storage |
Power | 4 AA Alkaline batteries (included) |
Run Time | Minimum 20 hours, typical battery life |
Approvals | EN 50270, CE mark, EN 50379 (pending) |
Display Languages Available | English, French, Spanish, Polish, German, Italian, Dutch, Danish |
Warranty (years): | Instrument, CO and O2 sensors - 2 Years |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.