Three functions in one instrument
Highlights
- Three functions in one instrument
- Easy and Speedy Touch Alignment
- 6.4 inch color TFT LCD
- Dual CCD Technology for Refractometry
- IOL / Cataract Mode
- New Indices for Keratometry: KAI, KRI
- Auto Alignment / Auto Shot for Topography
Three functions in One Instrument
Refractometer, Keratometer and Topographer only in 1 unit. Senior citizens and children can also get the inspection without any trouble because they don't have to move the seat for three measurements.
Switch from Ref-Kerato Mode to Corneal topography Mode with only ONE TOUCH. The light cone appears with only one button from the measuring head and the Ref-Keratometer is transformed to the Topographer.
Easy & Speedy Touch Screen Alignment
The Touch Alignment of the RT-7000 quickly aligns the eye center with the center of the screen by simply touching the eye shown on the screen. The Auto Alignment and Auto Shot functions then start measurement immediately.
Step 1- Simply touch the pupil center shown on the screen to roughly align the eye center with the center of the screen.
Step 2 - Lightly press the center of the screen to move the measuring head toward the patient. The Auto Alignment and Auto Shot functions will then quickly complete measurement.
6.4 inch Color TFT LCD
The 6.4 inch big color TFT LCD can be seen from anywhere, up, down, right and left of the display it is easy to measure while either sitting or standing.
Refractometry
Dual CCD technology for Refractometry
Two CCD cameras are used to capture images for observation and for measurement while providing highly accurate measurement data.
The viewing angle of the fixation target is wider to make patient relaxed during fixation to avoid accommodation.
IOL/Catract Mode
When it is difficult to measure pseudophakic or cataract eyes in normal mode, it can be switched to the IOL or Cataract Mode to match the state of examination eyes being examined.
It switches into the Cataract Mode automatically, too.
Diameter Measurement of Cornea and Pupil
The measurement can be done easily by moving the two cursors on the display to the boundary of Cornea or Pupil. This is useful for deciding the diameter of a contact lens.
Keratometory
New Indices for Keratometry: KAI, KRI
The Corneal Irregular Astigmatism display function is installed to expand the possibility of Keratometer. This is the new function to measure the level of Corneal Ireegular Astigmatism, which was difficult in the past.
The Indices of KAI and KRI that show the Corneal Irregular Astigmatism are displayed with its three levels (A - B - C) at Keratometry. (illustration in brochure, link below).
KAI: (Kerato-Asymmetry Index)
The Index indicating the asymmetry of cornea. This index becomes larger when the corneal shape is asymmetric.
KRI: (kerato-Regularity Index)
The index indicating the regularity of the cornea (higher-order irregular astigmatism). This index becomes larger when the corneal surface is not smooth.
It is possible to confirm the detail of the corneal shape with Topographer by switching to the Topography Mode with only "ONE TOUCH" if irregular astigmatism is suspected with KAI and KRI.
Fourier analysis of TMS separates and quantifies the refracting power on the surface of the cornea to "Spherical", "Regular Astigmatism", "Asymmetry" and "Higher-oder irregularity" show the Corneal Irregular Astigmatism.
Corneal Topography
Auto Alignment / Auto Shot
Anyone can easily capture measurements with Auto Alignment and Auto Shot.
The measurement variation is significantly reduced no matter what the skill level is of the operator.
Various Color Maps
Absolute and Normalized color maps can be viewed.
CL Fitting Simulation
A pseudo-fluorescein pattern of the contact lens selected from the built-in data base can be confirmed, and the fitting can be simulated before the patient wears the Trial Lens.
Corneal Eccentricity Index for "Ortho-K Lens" (CEI)
The index of CEI (Corneal Eccentricity index indicates the ratio of flattening in percentage from the central cornea to the periphery.
RT-7000 SPECIFICATIONS
Measurement Ranges
Refraction Measurement
Sphere: -25.00D to +22.00D (VD=12.0mm)
Cylinder: 0D to ±10.00D (VD=12.0mm)
Axis: 0 to 180º
Corneal Curvature Measurement: 5.00mm to 11.00mm (Measurement Zone: ø 3mm, R:8.00mm)
Corneal Mapping
Display Range: 9 to 100 D, –Normal Mode: ø1.0 to 8.0mm (R:8.0mm), –Special Mode: ø0.9 to 7.0mm (R:8.0mm)
Measurement Time
REF: 0.2 seconds
KRT: 0.1 second
Minimum Pupil Diameter: ø2.2mm
Minimum Measurement Step
Refraction Measurement
Sphere: 0.01D
Cylinder: 0.01D
Axis: 1º
Corneal Curvature Measurement: 0.01mm
PD (Pupil Distance): 50mm to 86mm
Recording: Built-in Thermal Printer
Vertex Distance: 0mm, 12.0mm, 13.5mm, 14.0mm, 15.5mm, 16.0mm
Exterior Output: LAN port / 4USB ports
Dimensions:
Hight: 466mm or 18 inches
Width: 307mm or 12 inches
Depth: 490mm or 19 inches
Weight: Approx. 20.00Kg (44.4lbs)
Display: 6.4 inch color liquid crystal display
Power Supply:
Voltage: AC 100 to 240V
Frequency: 50/60Hz
Consumption Power: 120VA to 150VA
Temperature: + 10Cº to + 40Cº
Display: 30% to 75%