Features:
Several working modes for users to freely set, multi-function:
P-1: time (timed) relays
P-2: time (delay) and relays
P-3: voltage relay
P-4: voltage control relay A
P-5: Voltage control relay B
P-6: voltage overload mode
P-7: voltage-limiting control relay
Relay coil input DC12V (optional DC5V or DC24V)
Voltage test range: 0-99.9V
A set of transformations (normally open normally closed)
Contact load: 10A/277VAC
Contact, contact resistance: ≤ 100m (1A-6VDC)
Mechanical durability: > 10 million times
Durability: > 100,000 times (10A-250VAC)
Working environment temperature:-40~85℃
Power save mode parameter, continued on after a power failure the last execution.
Digital module with socket installation can be directly removed.
Correction is settable voltage detection ( -0.3V~0.3V)
With power-on timer with auto-start function
Timing or delay time, number of times can be set, a single execution loop is executed multiple times
External pulse signals (rising edge) or switch to trigger action time relay
Relay load has three points of contact (a set of transformations): public, normally closed, normally
open points,
Relay when it is not powered on, the relay releases, public and the normally closed points connected,
when the relay coil power subsequent electrical snap, common Terminal and open access
Not short circuit the power supply connection
P-1 time (timed) relay mode
Use as a timed relay or relay, the default time range: 0-999 seconds or minutes, switch either according to
users ' demand to six hours/1-999 seconds to switch. (Before you buy, please contact)
Loops:
Time relay mode, the user can set the closing time of the relay release time T1 and T2, for example T1 set
for 3 seconds, T2 for 7 seconds, then relays the runtime can perform a 3 second another 7 seconds, release,
and so on.
When you set the T1 and T2 time value, the system power down to save the set value, the next time you run P-
1 mode is automatically included in the T1 time waiting to start running.
Until T1 and T2 are set press SET time value, and then press the SET key to set the loop execution times, up
to 999 times. Number is set to 0 then the infinite loop. When the timer is running, press SET button for
three seconds from switching to cycle count shows the number of.
Single execution time:
If you only set the T1 (closing time) and T2 (release time) is 0, then the relay during a scheduled stop
running the T1 time, no longer cycle to run, this time can be used as a timer T1 time scheduled finish,
relay release, short press the ENTER key at this time, the system starts in time T1 time.
If T1 (closing time) set to 0, the relay has been in a free State (does not start the run, normally closed
points connected, open fracture).
P-1 mode can also be used in computer power on, for example, you set the relay time 2 seconds, then the
external switching input shorted, on the relay Board is scheduled for 2 seconds and then disconnect when
not.
P-2 time (delay) and relay mode
Fully compliant with the P-1 mode P-2 mode, relay action instead of only, that is, first to a T1 time relay
release, into the T2 time relay. For example, you set T1 relay release time is 3 seconds, pull-in time T2
for 7 seconds, then the relay run time delay of 3 seconds before (keep release) 7 seconds to snap again, and
so, if you set up a loop, then after the cycle has ended, the relay releases.
Under P-1, P-2 mode, via external switch/pulse input interface, you can control the starting or stopping of
time relay. While the timer is running, external switch input does not affect the regular operation, pending
ended signal input external switches when you start the timer again.
If you switch to source pulse signal is triggered to start timer relay, you need an external pulse rising
edge (from low level to high level), if the input level remains the same (or switch not to work) do not
trigger starts the timer. Voltage relay mode, the user can be set to control the upper and lower limit
values, when the voltage exceeds the limit of detection of the relay, again released only until the voltage
drops below a set limit value relays, this feature can be used for voltage monitoring, battery discharge and
so can also be used as a DC voltmeter, voltage meter display range: DC 0-99.9V, error 0.1V. Working power
supply voltage can be detected and shared, but not below the guaranteed operating voltage 10V.
Short press SET key to enter the mode set the maximum voltage, voltage lower limit value status, voltage
calibration status, this product is factory-calibrated voltage accuracy, according to your own need to set
voltage correction -0.3~+0.3V, the default correction values are 0.
Press and release SET button for three seconds, the relay State is negated, that detect more than limited-
time relay on release, timed relay under test voltage is lower than the snap.
P-3 mode
Functions that can be used as a battery voltage monitoring, battery discharge, threaded through relay
power cement resistance load, can be used for battery discharge, when real time detection of battery
voltage is lower than the limit you set value, the relays to control loads automatically disconnected.
Factory default voltage control set upper and lower limits for the DC11.0V~10.5V.
Under P3 mode, press SET, and then enter the higher limit voltage settings; press it again, enter the
lower limit voltage setting; press it once more, then enter the voltage calibration status. You can
set the voltage correction -0.3~+0.3V, the default correction value is 0.
P-4, P-5, voltage control relay mode
P-4, P-5 models are "timed relay mode" and "voltage relay mode" combination or "time delay relay mode"
and "voltage relay mode" combination.
When you set a timer to run parameters, enter "P-4" or "P-5" mode detects the voltage to control the
timer starts or stops. By press and release SET button for three seconds, select the voltage exceed the
CAP to start the timer, start timer or voltage is lower than the lower limit.
P-4 mode when set to exceed the maximum voltage the timer is started, will remain below the lower
voltage relay release (normally open fracture, closed access). In contrast, when set to below the lower
voltage to start the timer, then timed relay will release on the higher voltage. And the only
difference is the P-5 model: P-5 mode, you start a timer when set to exceed the voltage limit, below
the minimum voltage relay, set to start below the lower voltage timer and timed relays on the higher
voltage will snap. In simple terms, P-4 initial release mode relay and relay initial P-5 mode to snap
State
When timer starts running, you can press the ENTER key to view the countdown time
By setting P-1 in timed mode, delay model and P-4, P-5 model P-2 combination program enables
a variety of applications:
1. The required test voltage across the 14.5V connected load for 5 minutes and then disconnect, load
disconnect when the voltage is less than 11.5V.
Setting method: first to a P-1 mode, set T1 to time 5 minutes, T2 is 0, then out of P-1 into P-4, and
set the voltage up to 14.5V, voltage lower limit is 11.5V, load relay normally open.
If you would like a voltage higher than the 14.5V disconnect the load, less than 11.5V load 5 minutes
to connect and then disconnect, press SET key for 3 seconds to inversion of relay logic.
2. Test voltage exceeds 14.5V delay 5 minutes and then connected to a load, load disconnect when the
voltage is less than 11.5V.
Setting method: first to a P-2 mode, set T1 to time 5 minutes, T2 is 0, then out of P-2 into P-4, and
set the voltage up to 14.5V, voltage lower limit is 11.5V, load relay normally open.
3. The requested test voltage is lower than the 14.5V delay 5 minutes and then connected to a load,
load disconnect when the voltage is less than 11.5V
Setting method: first to a P-1 mode, set T1 to time 5 minutes, T2 is 0, then out of P-1 into P-5, and
set the voltage up to 14.5V, voltage lower limit is 11.5V, load relay normally open. Long press SET key
for 3 seconds to start the timer when the voltage is lower than the lower limit, in this case, when
voltage is lower than the lower limit, you are starting a scheduled 5 minutes closed directly above the
upper limit of voltage.
4. A battery 11.5V you want to switch to the charging circuit and then charged for 10 minutes, than the
12V switched to load circuits.
Setting method:
A: cathode of battery and charging circuit and a load is connected to the negative pole of the circuit,
the relay common Terminal to battery cathode, often closed-end to load circuit cathode, often beginning
to charge circuit cathode, to charge the battery when the relay is closed at this time, release switch
to the load circuit wires go into P-1 mode to set clock for 10 minutes, then entered the P-4, set up to
12V, Lower bound of 11.5V, by long pressing the SET key for 3 seconds close the relay over upper closed
below the lower limit, you detect battery voltage of more than 12V relay release, switches to the load
circuit power, implementation of charging when the battery voltage is less than 11.5V for 10 minutes.
B: because some of the Chargers for charging pulse will make once the battery charging voltage when
mutation case, method 1 set, when charging the battery voltage immediately higher than the upper limit,
charging broken charging effect cannot be achieved. This situation can get into P-5, press SET key to
set below the minimum limit relay closed when 11.5V charge, start a scheduled 10-minute higher than 12V
charging then disconnected.
5. The application as voltage trigger signal timing, that is, to input voltage signal timing, and goes
on to set the start relay.
Example a: input voltage: 13V timing you want for more than 30 seconds, close the relay, voltage less
than 12V it reset all timers, relays do not work.
Setting method: first to a P-2 time delay relay mode (open and closed), T1 set P-2 30 seconds, T2 0,
into the P-4, set the maximum voltage is 13V, lower bound of 12V, at this time, voltages greater than
maximum 13V starts after a delay of 30 seconds has been closed, when voltage less than 12V will reset
all timers, relays are not closed.
Example b: input voltage of 13V time exceeds 30 seconds, the relay closing 2 seconds, and then
disconnect.
Setting method: T1 set P-2 30 seconds, T2 for 2 seconds, then you can enter the P-4, and set the
voltage lower limit on a same.
P-6 voltage limit mode
P-6 mode can be set to detect voltage within the range lower limit on the release, over lower range
relay snap on, press and release SET button for three seconds, switch on the voltage within the lower
range snap over lower limits on the release.
P-7 overrun and controlled voltage time relay
P-7 mode can be set to detect voltage relay remains in the lower range on release relay voltage exceeds
lower range on the start time. (P-4, and P-5 mode every time detection only can set for over ceiling started
timer, or set for below lower started timer, and P-7 mode can set for every time detection over ceiling and
below lower timer are started timer) implementation finished following electric release (timer set for
close~ release unlimited cycle will has been implementation, only detection voltage in lower range
within only will stopped), long by SET key three seconds release, can make voltage in lower range within
close switch for release.
Package Included:
1*Multifunctional Relay Controller
We ship your orders via Post Airmail within 1-2 business days after the payment cleared.
10-25 days to most countries via HK post airmail.
USA buyer also can choose epacket service, 7-15 days to arrive you.
Delivery time depends on destination, weather, customs and other factors, sometimes it will require a bit longer.
If you don't receive the item after 25 days, please contact us, we'll investigate and solve the delivery problem.
Payment methods accepted : Paypal only.
All major credit cards are accepted through our secure payment processor PayPal.
Payment must be received within 7 business days of auction closing.
We ship to paypal's address. Please make sure your paypal address is correct before you pay.
ALL emails would be replied within one business day! We will try our best to save your problem ASAP.
If there's any dissatisfaction, please contact us first so that we can help you.
Every item is checked carefully before shipping, buy with confidence!
Refund or replacement request is available only requests within a week after parcel received &returning the item as the same condition as received.
Please contact us before you return it, and pls include your eBay ID and brief description of defective problem in your return package.
Who bear the return cost? This will depend on the reason you want to return.
We will automatically leave positive feedback to every buyer to complete the transaction.
We maintain high standards pursuit of 100% customer satisfaction! Feedback is very important to us.