Measurement Response Time | Units | Operational Range | Resolution | Accuracy (+/-) | Specification Range |
Wind Speed 1 second | m/s | 0.4 to 60.0 m/s | 0.1 | | 0.4 to 40.0 m/s |
ft/min | 59 to 11,948 ft/min | 1 | | 59 to 7877 ft/min |
km/h | 1.0 to 218.0 km/h | 0.1 | Larger of 3% of reading or least significant digit | 1.0 to 144.0 km/h |
mph | 0.8 to 135.0 mph | 1 | | 0.8 to 89.0 mph |
knots | 0.6 to 118.3 kt | 0.1 | | 0.6 to 78.0 k |
Beaufort | 0 to 12 B | 0.1 | | 0 to 12 B |
1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5? off-axis; -2% @ 10?; -3%
@ 15?. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH /
27 m/s will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) may be
field-installed without tools (US Patent 5,783,753). |
Temperature 1 second | ?F | -49.0 to 257.0 ?F | 0.1 | 1.8 ?F | -20.0 to 158.0 ?F |
?C | -45.0 to 125.0 ?C | 0.1 | 1.0 ?C | -29.0 to 70.0 ?C |
Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally
(US Patent 5,939,645). Calibration drift negligible. |
Pressure 1 second
(mb & PSI 4000 model only) | inHg | 0.3 to 32.5 inHg | 0.01 | 0.05 inHg | At 77.0 ?F, 22.1 to 32.5 inHg |
hPa / mb | 10.0 to 1100.0 hPa / mb | 0.1 | 1.5 hPa / mb | At 25.0 ?C, 750 to 1100 hPa / mb |
PSI | 0.15 to 16.0 PSI | 0.01 | 0.02 PSI | At 77.0 ?F, 10.9 to 16.0 PSI |
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature
range 32 to 158 ?F (0 to 70?C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year.
Pressure sensor may be recalibrated at factory or in field. |
Altitude 1 second | ft | -6000 to 30000 ft | 1 | 50 ft | At 77.0 ?F, <19,700 ft. Max error +/- 98 ft |
m | -2000 to 9000 m | 1 | 15 m | At 25.0 ?C, <6,000 m. Max error +/- 30 m |
Temperature compensated pressure (barometric) altimeter. |
Wind Chill 1 second | ?F | 0.7 to 135.0 MPH, -49.0 to 257.0 ?F | 0.1 | 1.8 ?F | 1.8 to 89.0 mph, -50.0 to 50.0 ?F |
?C | 0.4 to 60.0 m/s, -45.0 to 125.0 ?C | 0.1 | 1.0 ?C | 0.4 to 40 m/s, -45.6 to 10.0 ?C |
Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill Temperature (WCT)
Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at
10 m above ground. (Specification temperature limits established by WCT Tables.) |
Max/Avg Wind Speed | One-button clear and restart of Max Wind Gust and Average Wind measurement. |
Pressure Trend | Continuously updating three-hour barometric pressure trend indicator: rising rapidly, rising, steady, falling, falling rapidly. |
Display | Reflective 4 digit LCD. Digit height 0.36 in / 9 mm. |
Display Update | 1 second. |
Display Backlight | Aviation green electroluminescent backlight. |
Clock / Calendar | Real-time hours:minutes clock. |
Operational Temperature Range (LCD and Batteries) | The operational temperature range of the liquid crystal display and batteries is 14? F to 131? F / -10 ?C to 55 ?C. Beyond
the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time
necessary to take reading. |
Storage Temperature | -22 ?F to 140 ?F / -30 ?C to 60 ?C. |
Auto Shutdown | After 45 minutes of no key presses. |
Certifications | CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge). |
Batteries | CR2032, one, included. Average life, 300 hours of use, +/-depending on backlight use. |
Environmental | Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.). |
Dimensions | Unit 4.8 x 1.7 x 0.7 in / 122 x 42 x 18 mm. Case 4.8 x 1.9 x 1.1 in / 122 x 48 x 28 mm. |
Weight | Unit 2.3 oz / 65 g. Case 1.3 oz / 37 g. |