Brief Introduction
MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
Features
◆ Separated connection between simulator probe and host, operation and test are more convenient.
◆ 262K color and 320*240 TFT, adjustable brightness level.
◆ Film key-press, makes the operation more comfortable.
◆ Power with chargeable lithium battery, can display the charge information of battery.
◆ Key volume, can open or close.
Main Functions
◆ Oxygen saturation simulation;
◆ Pulse rate simulation;
◆ Patient state simulation preset;
◆ Can test the reaction time of device;
◆ Can simulate the SpO2 and pulse rate under different amplitude;
◆ Can test the performance of device under different interference source;
◆ Can select different R-curve.
Main Parameters
◆ SpO2
Measuring range: 35%~100%
Resolution:1%
Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
◆ Pulse rate
Measuring range:25bpm~250bpm
Resolution:5bpm
Error:1%±1bpm
◆ Amplitude
Measuring range:0.000%~20.000%
Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
◆ Patient state
24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
◆ Voltage
DC 3.6V~4.2V
◆ Power Supply
Voltage 3.7 rechargeable lithium battery × 1
◆ Battery working life
Charge and discharge no less than 500 times.
Accessories
◆ A MS100 user manual
◆ A 5.0V adaptor
Buy safe products
The
following FDA Disclaimer is required for all eBay listing in Healthcare
category and is included for REFERENCE: The sale of this item may be
subject to regulation by the U.S. Food and Drug Administration and state
and local regulatory agencies. If the item is subject to FDA
regulation, we will verify your status as an authorized purchaser of
this item before shipping of the item.
The
Fingertip Pulse Oximeter is registered on the Australian Register of
Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of
United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that
is FDA 510K Approved
International Buyer--Please note:
Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
We are the manufacturer of medical equipment for 17 years, the following are our main products:
ECG / ECG holter EEG / EEG Holter B-ultrasound
Patient Monitor Fetal doppler Fetal Monitor
Spo2 Monitor Stethoscope Medical Image....
Agent in the world!
We are look for partners in the world now!
Do you want to become our agent in you conutry?