CE CONTEC MS200 NIBP SIMULATOR DYNAMIC BLOOD PRESSURE SIMULATOR,LCD DISPLAY

               

Product overview


MS200 NIBP Simulator is a multi-purpose  test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP)  Monitors. The appearance is concision ,operation is simple and convenient,with  its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3  kPa).The Simulator provides dynamic blood pressure simulations, static pressure  calibration, automated leak testing, and pressure relief valve testing.You can  quickly and exact analyse different NIBP Monitors. 


Main features 


Provides pressure gauge testing,pressure leak  testing,relief valve testing functions .

Build-in pump provides pressure source with  leak and pressure relief tests 

NIBP simulations for both arm and wrist  cuffs.

Provides adult,neonate, eight variations  patients conditions,user-defined simulations.

Provides arrhythmias,respiratory artifact  simulations.

Built-in air chamber to simulate adult and  neonate cuff.

65k colors,4.3" LCD  display.

Technical index 


Pressure measurement

Units:mmHg,kPa,cmH2O,inH2O,psi

Range:0mmHg-400mmHg

Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1  psi

Accuracy:0-300 mmHg:±0.5% of reading  ±1 mmHg;

    301-400 mmHg:±2%of  reading

Pressure Generator

Static Pressure Range:50 mmHg-400 mmHg

Resolution:1mmHg

Difference between target pressure and actual pressure  :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc 

Internal leak rate

<2 mmHg per minute, with a minimum volume of 300  cc

Pressure Leak Test

Pressure generate up to 400 mmHg (53.3 kPa) with  internal pump.The screen always show the peak pressures and the real-time  pressures.Leak rate displayed after 10 seconds. 

Pressure Relief Test

Pressure generate up to 400 mmHg (53.3 kPa) with  internal pump,Displays peak pressure.

Standard BP Simulations

Preset blood pressure:

  1#: BP: 120/80(93) HR: 80 Pulse Volume:  0.68

  2#: BP: 150/100(116) HR: 80 Pulse  Volume: 0.65

  3#: BP: 200/150(166) HR:  80 Pulse Volume: 0.60

  4#: BP:  255/195(215) HR: 80 Pulse Volume: 0.55

  5#: BP: 60/30(40) HR: 80 Pulse Volume:  0.75

  6#: BP: 80/50(60) HR: 80 Pulse  Volume: 0.71

  7#: BP: 100/65(76) HR: 80  Pulse Volume: 0.69

Patient Conditions 

BP Simulations

  Healthy: BP: 120/80(93) HR:75 Pulse Volume:  0.68

  Weak Pulse: BP: 110/80(90) HR:95  Pulse Volume: 0.50

  Mild Exercise: BP:  140/90(106) HR:120 Pulse Volume: 1.00

  Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume:  1.40

  Obese: BP: 120/80(93) HR:90 Pulse  Volume: 0.50 

  Geriatric: BP:  150/110(123) HR:95 Pulse Volume: 0.40

  Tachycardia: BP: 120/105(110) HR:130 Pulse Volume:  0.40

  Bradycardia: BP: 120/60(80) HR:45  Pulse Volume: 1.10

Arrhythmia Simulations

Premature Atrial Contract 1,Premature Atrial Contract  2,Premature Ventricular Contract,Atrial Fib and PVCs

Respiratory Artifacts

Spontaneous Breathing 1,Spontaneous Breathing  2,Spontaneous Breathing 3,Controlled Ventilation

Neonate simulations

User can select External or Internal  Neonate;

  1#: BP: 35/15 HR: 120bpm  Pulse Volume: 0.11

  2#: BP: 60/30 HR:  120bpm Pulse Volume: 0.10

  3#: BP:  80/50 HR: 120bpm Pulse Volume: 0.10

  4#: BP: 100/70 HR: 120bpm Pulse Volume:  0.10

Wrist simulations

1#: BP:120/80(93) HR: 80bpm Pulse Volume:  0.50

2#: BP:160/100(120) HR: 80bpm Pulse  Volume: 0.50

3#: BP:80/55(63) HR: 80bpm  Pulse Volume: 0.50

User-Defined simulations

Allows the operator to define blood pressure  simulations.

  Systolic(mmHg)  20-250

  Diastolic(mmHg)  10-200

  Heart Rate,(bpm)  30-250

  Pulse Volume,(cc)  0.1-2.4

Simulant characteristics

The maximum pulse volume:2.4cc

The maximum heart rate:250bpm,200bpm at pulse  volume>2.00cc.

Internal Adult cuff  volume:20cc

Internal neonate cuff  volume:300cc

Blood pressure units:  mmHg,kPa

Heart Rate  Accuracy:±1BPM

Patient  Conditions:

  Weak pulse,  Tachycardia,Obese,Geriatric ±1%±1BPM

  Mild exercise±1.5%±1BPM

  Strenuous exercise±3%±1BPM

Display

65k colors 4.3 inch TFT Display, brightness can be  changed.

Power

AC100 - 240 V 50/60 Hz, 60 VA

Environmental Conditions

Working temperature: 15℃ to 40℃(59℉ to 104℉)

Storage temperature: -20℃ to  +65℃(-4℉ to +149℉)

Relative humidity:  < 90%,No condensation.

Size (L x W x H)

27 cm x 26.5 cm x 13.2 cm

Weight

About 4kg

Accessories: 


Power cord

Fuse

User 's Manual


Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved

International Buyer--Please note:

Import duties,Taxes are not included in the item price.These charges are buyers' responsibility


We are the manufacturer of medical equipment for 17 years, the following are our main products:

ECG /  ECG holter   EEG / EEG Holter      B-ultrasound

Patient Monitor      Fetal doppler             Fetal Monitor 

Spo2 Monitor          Stethoscope              Medical Image....

Agent in the world!

We are look for partners in the world now!

Do you want  to become our agent in you conutry?

Join US!

Skype:xuebox3

contec.med.mary at hotmail.com


               
           
       
       
   
ibay365