Product Description


  • Inkbird temperature controller is a pre-wired heating thermostat with a timing function, especially for reptile breeding, incubation, and cultivation.
  • This heating thermostat can be set to two different temperatures with its dual function timing cycle for 24 hours after the day and night, which may better suited to the physiological needs of fish and aquarium plants.
  • This thermostat has overheating protection and automatic temperature control for all kinds of electrical equipment for the greenhouse heater, and heat mat.
  • With a dual LCD display, the temperature controller offers an optional display of Celsius or Fahrenheit, allowing humanized temperature control.
  • The dual heating thermostat has Temperature calibration, the temperature may become more accurately controlled with its function of temperature calibration and temperature hysteresis.
  • Plug & Play design, easy to use. Just plug the heater in sockets at the ITC-306, and set your desired temperature to be ok.
  • Temperature range: -50~99 °C / -58~210 ° F. Maximum total output load: 2200 W (220 V).Input Power: 100 ~240VAC, 50Hz/60Hz. Temperature Control Output: Max. 10A, 100V ~240V AC

Digital Thermostat ITC-306T (Heat)

Product parameters


    • Relay Contact Capacity: Heating (10A,220VAC)
    • Temperature Resolution: 0.1 ° C / 0.1° F
    • Temperature Accuracy: ±1°C (-50 ~ 70°C) / ±1°F (-50 ~ 160° F)
    • Ambient Temperature: -30~ 75 ° C / -22~ 167 ° F
    • Socket (AU Version): 140x51x27mm (5.5x2.0x1.0 inch)
    • Storage Temperature: -20~ 60 ° C / -4~ 140 ° F
    • Storage Humidity: 20~85% (No Condensate)

 

There will be 2 situations when you use this reptile thermostat:


'PV' is the current temperature

'SV' is the setting temperature

'TS' is your target value

'DS' is the differential value 'CA' is the calibrated value

'CF' is the unit of temperature (C or F)

'TR' is time setting ( 0:off / 1:on )

1. If you only need to control one temperature range the whole day:

Your ideal temperature range: is 22~25C, the settings are as follow:

TS1=25, DS1=3, CA=0, CF=C, TR=0

With this setting, when the PV actual temperature is lower than TS1-DS1=25-3=22C, the work light will turn on and your heaters will start outputting until the temperature reaches 25C (TS1/SV), and it will stop.

2. If you need to control different temperature ranges during day and night:


Your ideal temperature range: during 8:00~18:00, keep the temperature within 22~25C, during 18:00~8:00, keep the temperature within 27~25C

TS1=25, DS1=3, CA=0, CF=C, TR=1, TS2=27, DS2=2, TA=8, TB=18, TH=the hour of the current time when you set, TM= The minute of the current time when you set

During (8:00~18:00) TA~TB, the thermostat will work with TS1 and DS1. During (18:00~8:00) TB~TA, the thermostat will work with TS2 and DS2


On 05/01/2023 at 18:14:04 AEDT, seller added the following information:

DataCaciques