Product Main Function

1. Measurement of H/L voltage AC leakage current (operate with insulation rod above 600V)

 

2. Range : 0.00mA~60.0A

 

3. Resolution : 0.01mA

 

4. Data Storage : 99 groups

 

5. Line Voltage : Test of the wire with insulation skin below 60kV, test of  bare wire below 35kV (operate with insulation rod)

 

6. CT Size :φ68mm

 

   ETCR 9220 H/L Voltage Clamp Current Meter adopts CT  technology and mask digital integration technology, the instrument composed of special clamp current meter and  high voltage insulation rod, If not use  insulation rod, which can be used as high accuracy low voltage clamp current meter.

 

      ETCR 9220 H/L Voltage Clamp Current Meter connect with insulation rod, which can use for hight voltage line current measurement of   the wire with insulation skin below 60KV or  bare wire below 35KV, online current measurements, also with peak hold, data hold and data storage and so on function, the special clamp current meter convenient to clamp or withdraw the tested wire operate by push or pull back the insulation rod.It is widely used in substations, power plants, industrial and mining enterprises, inspection stations, electrical maintenance departments for current detection and electrical field operations. It can replace the H/L voltage transformation ratio tester, which can measure the H/L voltage current of the primary circuit and the secondary circuit respectively, and then calculate the H/L voltage transformation ratio. The insulation rod is handiness, and has the characteristics of moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation, scalable and so on.

 

Technical Parameter

Function

Description

 Function

 Measurement of H/L voltage AC leakage current

 Power Supply

 DC 6V (LR03×4 alkaline dry batteries)

 Measurement Method

 Clamp CT, integration method, the instrument can be hung on the line to test, more convenient to operation

 CT Size

 φ68mm

 Range

 0.00mA~60.0A(50/60Hz automatic)

 Resolution

 0.01mA

 Shift

 0.00A~60.0A automatic shift

 Accurac(23℃±5℃RH<80%)

 0.00mA~999mA:±1%±5dgt

 1.00A~60.0A:±1.5%±5dgt

 Sampling Rate

 2 time/second

 Display Mode

 4-digit LCD display

 LCD Size

 Detector: 35mm×21.5mm

 Meter Size

 Detector: 135mm×218mm×60mm

 Data Storage

 99 groups , stored process display MEM symbol, “FULL” symbol display indicate that storage full

 PEAK Hold

 Automatically hold the highest test value,In usual test mode, press PEAK key The "PE" symbol is displayed in the upper right corner of the LCD to keep data, Press the PEAK key again to cancel this function.

 Line Voltage

 Below 60kV current test with insulated skin wire; below 35kV bare wire test (operate with insulation rods)

 Data Hold

 In general test mode, press HOLD key to hold data, “DH” symbol display. press HOLD Key once again to cancel this function

 Data Access

 “MR” symbol indication, can access all storage data

 Overflow Display

 Exceed measure range overflow function: “OL A” symbol display

 Automatic Shutdown

 15 minutes after boot up, the meter shuts down automatically without any operation, to reduce battery consumption

 Batter Voltage

 When battery voltage is lower than 4.8V, display low battery voltage symbol “ ”, and remind to replace the battery

 Weight

 3930g including insulation rod and battery

 Working Environment

 -10℃~40℃; Below 80%rh

 Store Environment

 -10℃~60℃; Below 70%rh

 Interference

 Should avoid extremely strong electromagnetic fields, avoid 315MHz, 433MHz same-frequency signal interference

 Insulation Rod Dimension

 φ32mm,1m×5PCS

 Insulation Rod Withstand Voltage

 Detcetor/Receiver: AC 2kV/rms ( between the out shell screws)

 AC110kV/rms(all 5pcs insulation rod connect, between the two ends) 

 Structure

 Anti-Dripping Type II

 

 

Package

 Outer Package

 Carton

 Inner Package

 Cloth bag

 Accessory 

 Detector

 1 PCS

 Insulation Rod(1M)

 5 PCS

 Tool Bag

 1 PCS

 Manual

 1 PCS

 Certificate

 1 PCS

 Warranty Card

 1 PCS

 

 
Payment:
●Accepts payment with PayPal. Via paypal you can use all major credit cards. Items do not ship until payment is recieved in full.
 
Shipping:
  • Items are only shipped after PAYMENT is received
  • Please check out your ADDRESS carefully when processing order
  • If you haven't received the parcel in 25 days,please allow us 2-3 days for checking undelivered packages before we issue you refund
  • We can't ship to African countries becasuse of shipping company policy.
  • To Austrilia,USA and UK7-15 days by e-package, others 15-45 days by Singapore Post or Hongkong Post
  • If you want to send DHL / UPS / TNT/ Fedex please contact me alone to change the price
 
Custom Tax
Attention! eBay Custom Tax Policy
●The policy of customs clearance may differ from each country.
●We are not responsible for any applicable customs charge, taxes and duties.
●Import duties and taxes are buyer's responsibility.
●If you have any inquiry for custom clearance, please leave a message.
●We will mark the price you want to declare after communication.
 
Feedback:
●We rely on our reputation and customer satisfaction to succeed,Therefore,your feedback is extremely important to us ,please leave good feedback to us if you get satisfied with our goods and service.
●We care about our valued customers,and will always try to help you.
●Please give us the opportunity to resolve any problem.We understand the concerns and frustrations you might have,and will try your best to resolve the issues.
●Please email us before leaving any negative feedback or opening any dispute on the site.We will help you to resolve the problem.
 

             

DataCaciques

Track Page Views With
Auctiva's Counter