50 meters Original ENCO TÜV Solar Panel PV Insulated Cable DC Rated Black 6mm²

CET SOLAR CABLE Black  6mm2 1.0/1.0 kV H1Z2Z2-K TÜV Rheinland Type Approved R60113052 IEC 60332-1 CE

Nominal Voltage Uo/U - 1.0/1.0 kV AC – 1.5/1.5 kV DC

Maximum per mitted voltage - 1,8 kVDCv

Test Voltage - 6.5 kVAC

Operating Temperature - (- 40 ÷+90°C)

Max core temperature (+120°C for 20.000hrs.)

Min bending radius - 5 x D cable (fixed installation)

Approved- TÜV Rheinland

References: EN 50618:2014 IEC 60228, EN 50395, EN 50396, EN 60332-1-2, EN 61034-1; -2, EN 50525-1, EN 60216-1; -2

TYPE - TÜV SOLAR CABLE

SECTION - 1x6.00 mm2

MAX WIRE DIAMETER OF CONDUCTOR - 0.31 mm

INSULATION THICKNESS 1ST / 2ND - 0.70 / 0.80 mm

OVERALL DIAMETER - 6.20 mm

RAME STAGNATO TINNED COPPER - 3.39 Ω/Km

REACTANCE (at 50 Hz) - 0.135 Ω/Km

Diameters tolerances: according with TÜV standards

Properties: The cable is able to satisfy the latest requirements fixed for PV systems in accordance to the following Reference Standards: EN50618 – EN 60216-1-2 – EN 61034. The special insulation has qualities of high abrasion resistance to high temperature. Moreover the insulation has property of flame retardant and ozone resistance The cable is UV-resistant and the external sheath can be removed from the inner layer of extruded insulation.

TÜV SOLAR CABLE (H1Z2Z2-K) APPENDIX

The H1Z2Z2-K is to be considered Harmonized because has been tested and certified in accordance with the requirements of the harmonized standard EN 50618: 2014 (quoted in the official document of the European Union that lists the harmonized standards to the LVD Directive 2006/95/EC (Low voltage Directive). Use and type of installation for applications in photovoltaic (HD 60364-7-712). For fixed installation indoors and outdoors. Installation of walls, walkways, pipes, conduits, and similar systems. The cables are suitable for use with Class II. They are inherently short-circuit and earth fault proof acc.to HD 60364-5-52. 

Chemical properties 

Halogen-free: acc. to EN 50525-1 Annex B (EN 50267-2-1, EN 50267-2-2, IEC 60754-1, IEC 60754-2)

Low Smoke Emission: acc. to IEC 61034, EN 61034 (Light Transmittance > 60%)

Weather resistance: Ozone resistance: acc. to EN 60811-403 Test Method A, EN 50396 clause 8.1.3 Test Method B Weathering/UV resistance: acc. to EN 50618 Annex E, EN 50289-4-17 (Method A), EN ISO 4892-1 /-2 tensile strength and elongation at break after 720h (360 Cycles) of exposure to UV lights

Acid and alkaline resistance: acc. to EN 50618:2014 Annex B: 7 days, 23° C (N-Oxalic Acid, N-Sodium Hydroxide) as for EN 60811-404

Resistance to fire: Flame propagation acc. to EN 60332-1-2 (Single Cable Flame Test) Tested according to CPR: EN 50399 Common test methods for cables under fire conditions Heat release and smoke production measurement on cables during flame spread test, UNI EN 13501-6 Flammability class: Dca Smoke emission class: s2 Drip particle class: d2 Fume acidity: a1 

Mechanical properties 

for insulation and sheath before ageing acc. to EN 50618 Annex B (test acc. To EN 60811-501). tensile strength ≥ 8 N/mm² elongation at break for insulation and sheath ≥ 125 % 

Shrinkage test on sheath: acc. to EN 50618, Table 2: <2% (test acc. to EN 60811-503).

Dynamic Penetration Test: acc. to EN 50618

Durability of Print: acc. to EN 50618 (test acc. to EN 50396)

Direct Burial: Impact test resistance of single conductor type USE and USE-2 cables (tested acc. to UL854)

Rodent resistance (optional): Rodent resistance safety can be optimized by utilizing a special compound alternative: braid metallic coatings

Water resistance: AD8 category Tested with successful acc. to EN 50525-2-21 “Annex E” (after immersion for 100 days / 2.400 h to 50°C): 

  •  Voltage at 1 kV AC on cable in water at 50°C during 100 days without any breakdown 
  •  Mechanical properties on sheath after immersion 100 days at 50°C • Minimum tensile strength after immersion 100 days at 50°C > 7 MPa 
  •  Minimum elongation at breack after immersion 100 days at 50°C > 200% 
  •  Water absorption on sheath after immersion 100 days at 50°C less than 40% 
  •  Insulation resistance tests with a minimum resistivity of 1011 Ω.cm measured after 14 days in water at 50°C

Long term resistance of insulation to d.c: acc. to EN 50618, Table 2 test acc. to EN 50395 clause 9: Cable immersed in water containing 1% NaCl for 240h ; water temperature: 85°C ± 5; Voltage applied: 1.8 kV D.C. 

Thermal properties 

Lifetime: acc. to EN 50618 : 25 years the cables are designed to operate at a normal max conductor temperature of 90°C, but for a maximum of 20.000 hours a max. conductor temperature of 120 °C at a max. ambient temperature of 90 °C is permitted. (test according to EN 60216-1 and EN 60216-2)

Max short circuit temperature: 250°C (for 5 sec.)

Resistance to cold: EN 50618,

  •  Cold Bending Test at -40°C acc. to EN 60811-504; 
  •  Cold Elongation Test at -40°C acc. to EN 60811-505; 
  •  Cold Impact Test at -40°C acc. to EN 50618 Annex C and EN 60811-506. 
  •  Damp-Heat Test Acc. to EN 50618, Table 2 (test acc. to EN 60068-2-78) : 90°C for 1.000h and min. 85% humidity