6.2KW On/Off-Grid Solar Hybrid Inverter 48V AC220V 120A Solar Charger Controller

Advantages:

🔢【PURE SINE WAVE INVERTER】6200W 48V Off-Grid Solar Inverter Built-in 120A MPPT Charge Controller, Pure Sine Wave Inverter Single-phase output 230VAC, 6.2kw new all-in-one inverter combining functions of inverter, solar charger and battery charger to offer uninterruptible power support in a single package.
🔢 【TECHNICAL PARAMETERS】120A MPPT Solar Charging Inverter, MAX. PV Array Power: 6500W, Max.PV Open Circuit Voltage: 450Vdc; Starting voltage >90V, MAX. Charging Current:120A, PV Array MPPT Voltage Range: 60~450Vdc; Cold start function(46V).
🔢 【TWO LOAD OUTPUT POWER】Setting range is from 40.0V to 46.0V for 6.2KW model. Increment of each click is 0.1V. When the battery voltage falls below the setting range, the Main OUT port stops working.Only the Second Out port will work. For areas with frequent power outages and loads that can't be blacked out, you can set the battery voltage to 46V. Keep more battery capacity for emergencies.If the battery voltage is higher than 46V, the Main OUT port will continue to work.
🔢 【One Click Restore Default Settings】6.2KW All in One MPPT inverter can restore the system settings by one key in case of setting error, avoiding the machine damage caused by setting error. with battery cold start function(46V) ,and automatic restart while AC is recovering to well protect your system.
🔢 【DIVERSIFIES USES】You can use inverter as energy storage device without power Grid (Off Grid). Can be accessed to a variety of household and office loads, including refrigerators, lamps, televisions, fans, air conditioning and other loads. 4 charging modes support: Utility first, Solar first,Solar&Utility and Battery & Solar.
🔢 【Tips:Not for 120V】 This solar hybrid inverter in some parts of the US: does not support parallel operation, nor does it support split phase operation! (Single phase/hot leg 230V output, not 110V AC output) For 110/120V US home appliance equipment, you can simply add a converter (not included) to step down the 220/240V AC power to 110/120V AC power, then your 110V home appliances can also be used at the same time, this inverter can not output 110V power, this is a 220V output inverter.

 

Features:

•Pure sine wave inverter
•Configurable input voltage range for home appliances and personal computers via LCD setting
•Configurable battery charging current based on applications via LCD setting
•Configurable AC/Solar Charger priority vía LCD setting
•Compatible with mains voltage or generator power
•Auto restart while AC is recovering
• Overload/ Over temperature/ short circuit protection
•Smart battery charger design for optimized battery performance
•Cold start function

  • Only Solar: Solar energy will be the only charging source even if utility is available.
  • Utility Priority : Utility will provide power to the loads as first priority.

Solar and battery energy will provide power to the loads only when utility power is not available.

  • Solar Priority: Solar energy provides power to the loads as first priority.

If solar energy is not sufficient to power all connected loads, battery energy will supply power the loads at the same time.

  • Hybrid Charging: Solar energy provides power to the loads as first priority.

If solar energy is insufficient to power all connected loads, battery energy will supply power to the loads simultaneously.

Three-Load Working Mode:

  • SOL: Solar energy provides power to the loads as a priority, then Battery, then Utility AC power.
  • UTI(Default): Utility will provide power to the loads as a priority, then Solar and Battery power.
  • SBU: Battery power load first, then Utility.
MODELPOW-HVM6.2M-48V-N
Phase1-phase
Maximum PV Input Power6000W
Rated Output Power6200W
Maximum Charging Power6200W
GRID-TIE OPERATION
PV Input(DC) 
Nominal DC Voltage/Maximum DC Voltage360VDC/500VDC
Start-up Voltage/initial Feeding Voltage120VDC
MPPT Voltage Range90VDC~450VDC
Number of MPPT Trackers/Maximum Input Current1/27A
GRID OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195.5-253VAC
Nominal Output Current15.7A 26.1A
Power Factor>0.9
EFFICIENCY
Maximum Conversion Efficiency(DC/AC) 97%
OFF-GRID OPERATION 
AC INPUT
AC Start-up Voltage/Anto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC OR170-280VAC
Maximum AC Input Current40A
PV Input(DC)
Nominal DC Voltage500VDC
MPPT Voltage Range90VDC-450VDC
Number of MPPT Trackers/Maximum Input Current1/27A
BATTERY MODE OUTPUT(AC)
Nominal Output Voltage24VDC 48VDC
Output WaveformPure sine wave
Efficiency(DC to AC)94%
HYBRID OPERATION
PV INPUT(DC)
Nominal DC Voltage/Maximum DC Voltage360VDC/500VDC
Start-up Voltage/initial Feeding Voltage120VDC
MPPT Voltage Range90VDC-450VDC
Number of MPPT Trackers/Maximum Input Current1/27A
GRID OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195.5-253VAC
Nominal Output Current15.7A 26.1 A
AC INPUT
AC Start-up Voltage/Anto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Maximum AC Input Current40A
BATTERY MODE OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Efficiency (DC to AC)94%
BATTERY & CHARGE
Nominal DC Voltage48VDC
Maximum Solar Charging Current120A
Maximum AC Charging Current80A
Maximum Charging Current120A
GENERAL 
PHYSICAL 
Dimension   D *W *H420*310*120
Net Weight(kgs)13
INTERFACE
Communication PortRS232/WIFI/BMS
ENVIRONMENT
Humidity0-90%
Operating Temperature-10 to 50 °C
 
 
Basic System Architecture
The following illustration shows the basic application for this inverter/charger. It also includes the following devices to have a complete running system:
• Generator or Utility.
• PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in-home or office environment, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.
 

Important Note:

1. In utility bypass mode, the device cannot be connected to two-phase 220V AC, i.e. L1-L2 cannot be connected to L-N.

2. In inverter mode, after the device is connected to two-phase 220V, please do not select utility priority for the output priority, so as not to cause safety hazards to the device.

3. Please do not connect the AC output of the device to the autotransformer, so as not to affect the normal service life of the device.

 
 
PushAuction