U.S.A. JENCO Ren's 9010M Thermometer Portable DO Temperature Tester Distribution Pole LD-900-11
 
U.S. JENCO Ren's 9010M Thermometer Portable DO Temperature Tester Distribution Pole LD-900-11
Product Description
Thank you for purchasing the 9010M. 9010M is a precision instrument for measuring dissolved oxygen and temperature, with a built-in microprocessor that calculates and compensates for all measurements related to dissolved oxygen and temperature.
The instrument has a waterproof case, mechanical keypad for high confidence, high tactile and audible alarms, and is powered by a single 9V dry cell battery. The calibration data is permanently stored in the EEPROM memory, so that no further calibration is required for the next time the instrument is used.
The instrument uses a large LCD to display temperature-compensated dissolved oxygen values and related indications. Even during calibration or measurement procedures, various user prompts are provided.
The 9010M has a memory function for 50 sets of measurement data, and stored measurement data can be easily accessed through the callback screen. Stored data can also be deleted in its entirety or individually via the clear screen.
The 9010M is supplied with a battery operated Dissolved Oxygen Electrode: LD-900-11, which has a built-in temperature sensor that automatically senses the temperature. 9010M also includes automatic range switching, automatic temperature compensation, long battery life, and 50/60Hz AC noise immunity, making it suitable for use in the field and in the laboratory.

Product Specification Features
Jenco Model 9010M Portable Dissolved Oxygen/Temperature Tester Features
9010M can measure dissolved oxygen, air saturation, temperature Calibration value power failure memory function Automatic temperature compensation function Manual pressure, salinity compensation 50 sets of measurement data memory function Battery low warning Automatic power off function Waterproof body design Imported polarographic dissolved oxygen electrode CMC, ROHS, CE certification
Jenco 9010M Portable Dissolved Oxygen/Temperature Tester Specifications
reveal Radius Resolution precision
Dissolved oxygen 0.00 to 20.00 ppm 0.01ppm ±0.5%FS
Air saturation 0.0~200.0% 0.1% ±0.5%FS
temperature -6.0~46.0℃ 0.1℃ ±0.3℃±1个字
Pressure compensation 600~1100mBar The default value is 1013mBar
Salinity compensation 0.0~40.0ppt The default value is 0.0ppt
Electrode type Polarographic formula
Calibrate data storage functions Yes, 50 sets
Automatic temperature compensation Yes
Power source 9V battery
Working environment 0~50℃,Relative humidity<90%
Weight/size Approx. 260g(without battery)/186x70x37mm
Standard configuration
9010M Main machine, LD-900-11 electrode, LD-900-3A electrode die head, 9V battery, carrying case
JENCO 9010M portable dissolved oxygen (DO)/temperature tester can measure dissolved oxygen, air saturation, temperature. 9010M is a full-featured, cost-effective waterproof portable dissolved oxygen measurement, which can be used for environmental protection, water treatment, aquaculture, schools and other industries. 9010M configuration of imported DO electrode, the electrode built-in temperature sensors to make the test data more accurate and convenient. accurate and convenient.

Product operation instructions

Dissolved oxygen calibration 9010M in the calibration bottle to do calibration, calibration process is simple, fast.
1. Connect the dissolved oxygen electrode LD-900-11 to the input port of the main unit, and then press the on/off key to switch on the unit. 2.
2. Place the prepared electrode and the electrode bottle vertically and press the ‘MODE’ key to select the ‘Dissolved Oxygen --%’ mode. 3.
3. Wait for the temperature and dissolved oxygen value to stabilise, then press the ‘CAL’ key to enter the ‘calibration’ mode, at this time, the font of ‘CAL’ will be displayed on the interface, and the main display will display At this time, the font of ‘CAL’ will be displayed on the interface, and the main display will show ‘1013mBar’ (factory setting), and the machine will prompt you to input the local atmospheric pressure. 4.
4. Press ‘UP’ and ‘DOWN’ key to increase and decrease the atmospheric pressure value (adjustment range: 600~1100 mBar), press ‘ENTER’ key to confirm, the machine will store this atmospheric pressure value and enter the next step. Press ‘ENTER’ key to confirm, the machine will store this atmospheric pressure value and enter the next calibration interface: the setting of saturated oxygen in air (100%). If you press the ‘MODE’ key at this time, the machine will not store the adjusted atmospheric pressure value, but will calculate the last stored atmospheric pressure value and enter the next calibration interface: setting of saturated oxygen in air (100%). 5.
5. In this interface, the user will see the second display of 100% saturated oxygen correction value, when the main display value is stable, please press the ‘ENTER’ key, at this time the machine will store the second display of 100% saturated oxygen correction value and enter into the next calibration interface: the setting of salinity. If you press the ‘MODE’ key at this time, the machine does not store 100% of the saturated oxygen correction value, or calculate the last stored 100% of the saturated oxygen correction value, and enter the next calibration interface: salinity settings.
6. The factory value of salinity is set to 0.0 ppt, to adjust this factory value, please press the ‘up key’ and ‘down key’, the adjustment range is: 0 ~ 40 ppt, press ‘ENTER Press ‘ENTER’ key, then the machine will store the set value and enter the measurement mode directly. At this time, the calibration of the whole machine has been completed.
If you press ‘MODE’ key, the machine will not store this salinity value, but still calculate the last stored salinity value and enter the measurement mode directly.
Packing:1PC
Warranty period: 120 days


On Apr 26, 2024 at 03:51:20 PDT, seller added the following information: