Elitech GPS-6 data logger is mainly used to record the temperature and humidity of food, pharmaceuticals, and chemicals, etc. It is widely applicable to each link in the storage and logistics of the cold chain, such as refrigerated containers, refrigerator trucks, cooler bags, cooler cabinets, medicine cabinets, cold storage, laboratory, etc.
It can also automatically shorten the record interval in case of over temperature and humidity limit. It will buzzer and the red indicator will flash if it is over the limit.
When you first use the data logger, please install our free data-management software. Once you connect it to your Win/Mac system, the log interval, C/F temperature unit (showed both on report and screen), alarm limits can be adjusted via the USB cable. In addition, data could be saved, graphed, exported, and in Excel/PDF format.
|
|
|
|
---|---|---|---|
MAX & MINLarge screen display. Easy to read the current temp & humid readings. Max and min temperature and humidity displays both on the device and report. Records up to 16000points. |
Audible & Indicator AlarmsSettable high and low temperature alarm. Hear or view your alarm easily. Detailed alarm info is shown in the report. |
2 Sensor ProbesWith one temperature sensor and one temp & humid combined sensor, Elitech GSP-6 supports 3 combinations of sensor types. |
Calibration CertificateProvide calibration certificate including calibration date and calibration date for each S/N number |
|
|
|
|
---|---|---|---|
Easy InstallationWith two pieces of built-in magnets, it can be easily installed on walls, cold storage doors, cabinets, or other metal applications. |
Start & Stop LoggingPress and hold the button for 5 seconds until the “Solid Triangle” icon or “Solid Square” icon shows on the screen, indicating the logger start/stop logging. |
Export Free Data Report from SoftwareConnect the data logger to your computer and use ElitechLog software to save or export the data. |
Reset & Reuse the LoggerClick "Quick Reset" to reset the orignal parameters settings. Disconnect the device from your computer to start using again. (Please see User Manual for more detailed instructions) |
Temperature Measurement Range | -40°C~+85°C (-40°F~185°F) |
Temperature Accuracy | TH Probe: ±0.3°C/±0.6°F (-20°C~+40°C), ±0.5°C/±0.9°F (others) T Probe: ±0.5°C/±0.9°F (-20°C~+40°C), +1°C/±1.8°F (others) |
Humidity Measurement Range | 0%RH~100%RH |
Humidity Accuracy | ±3%RH (25°C, 20%RH~80%RH), ±5%RH (others) |
Resolution | O.1°C/°F; 0.1%RH |
Memory | Maximum 16,000 points |
Logging Interval | 10 seconds to 24 hours |
Data Interface | USB |
Software | ElitechLog, for macOS & Windows system |
Report Format | PDF/EXCEL/TXT*via ElitechLog software (TXT for Windows ONLY.) |
Power supply | single-use 3.6 V ER14505H lithium battery or powered via USB |
Battery life | two years at room temperature with 15 minutes record interval and buzzer alarm disabled |
Certification | EN12830, CE, RoHS |
Dimensions | 118x61.5x19 mm |
GSP-6 | GSP-6G | |
---|---|---|
Record Capacity | 16,000 Temperature points, 16,000 Humidity points | 16,000 Temperature points, 16,000 Humidity points |
Temperature Range | -40°F to 185°F(-40°C ~+85°C) | -40°F to 185°F(-40°C ~+85°C) |
Humidity Range | 10%~90%RH | 10%~90%RH |
Sensor Type | 2 metal sensors | 1 metal sensor & 1 glycol bottle sensor |