DC12V/Micro USB 5-30V Trigger Cycle Delay Timer Control Relay Switch Module

4 Button 4 Digit Digital Tube:
Item Special:
1: Product model: YYC-2S 24 common functions, to meet more application needs; can control solenoid valves, pumps, motors, lights, etc.
2: Input voltage: DC 5/12/24V optional
3: Output power: can control DC or AC load within 10A
4: Time range: 0.01 seconds to 999 minutes adjustable at any time
5: Description of the wiring port:
(1) DC+: input DC power supply positive
(2) DC-: input DC power supply negative
(3)IN+: positive input terminal
(4) IN-: signal input terminal
(5) NO: relay normally open interface, the relay is suspended before the suction, after the suction and short circuit with COM
(6) COM: relay common interface
(7) NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed.
1: Function list:
P-11: Jog P-12: Self-locking P-13: Give signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay.
P-14: Give signal, relay will stop automatically for A seconds; trigger re-time during delay
P-15: Give signal, relay is automatically stopped for A seconds; trigger timing is triggered during delay
P-16: Give signal, relay will stop automatically for A seconds; trigger reset during delay
P-17: Give signal, relay is closed, input signal is disconnected, output is off after A seconds
P-18: After power-on, the relay will immediately pull in, after a delay of A seconds, the power will be turned off;
P-21: Disconnect the signal relay, after a delay of A seconds, the relay pulls in
P-22: Give signal, after more than A seconds, the relay pulls in, the signal disappears, the relay stops.
P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops.
P-24: There is a signal. After more than A seconds, the relay is closed. When the signal disappears for more than A seconds, the relay stops.
P-25: There is a signal after more than A seconds, the relay is closed, and after a signal exceeds A seconds, the relay stops.
P-26: There is a signal. The relay stops after A seconds of suction, and the signal disappears. The relay stops again after A seconds.
P-27: The pulse signal is detected and the relay is closed; if there is no pulse signal, the relay delays for A seconds;
P-28: After power-on, after a delay of A seconds, the relay pulls in until the power is turned off.
P-31: After power-on, the relay pulls in for A seconds, disconnects B seconds, infinite loop; power-off stops P-32: signal, start P-31
P-33: Give a signal, start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, after a delay of A seconds, the relay pulls in and closes after B seconds.
P-35: There is a signal. After a delay of A seconds, the relay pulls in and closes after B seconds.
P-36: There is a signal. After more than A seconds, the relay pulls in and closes after B seconds.
P-37: There is a signal, the relay will stop automatically for A seconds, and then stop for 24 seconds. The signal trigger is invalid during A+B time.
P-38: There is a signal, the relay will stop automatically for A seconds, stop and re-time for B seconds, and then automatically close for A seconds.
P-41: There is no signal; the signal disappears; the relay works after the delay of A time.
P-42: The signal disappears, after a delay of A time, the relay works; the end of work B time
P-43: The signal disappears. After the A time, the relay works; the working B time ends.
P-44: After power-on, the relay works for A time, and stops B time; the cycle stops automatically for C times.
P-45: The power is not activated, after the signal is given; the relay works for A time, the B time is stopped; the cycle C stops automatically; the signal is given again, once again
P-46: After the signal is sent for more than A times, the relay is closed; the suction is kept; the power is stopped.
P-47: After the signal is sent for more than A times, the relay is closed for B seconds.
P-48: In C seconds, after the signal is continuously sent for more than A times, the relay is closed for B seconds.
2: Button setting instructions:
The power-on display “————” means to enter the standby state;
Press K1 for the first time (more than 1 second is required to prevent false triggering)
Screen display: P -11: K2 adjusts the main mode, K3 and K4 adjustment functions
Press the second time K1, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Pressing the third K1, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Pressing the fourth K1, “————” means entering the standby state;
Press K4 in standby mode to permanently turn off/on the display and switch the low power mode.
X.XX decimal point in hundred, timing range: 0.01 seconds to 9.99 seconds
XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
XXX has no decimal point, timing range: 1 second ~ 999 seconds
XXX. The decimal point is in one place, the time range is from 1 minute to 999 minutes.
 
3 Button 3 Digit Digital Tube:
Description :
New upgrades to simplify,to meet customer needs.
Increase the supply anti-reversefunction.
The use of opto isolated input and output,enhanced anti-jamming capabilit
consumption.
Set parameter after power for ever memories.
Signal terminal voltage signal can be maintained for a longtime.
to ensure stability,industrial grade board,class PLC.
Product parameters:
Size:64.2mm*34.8mm*18.5mm.
Relay Specifications:AC 220V 10A or DC 30V 10A.
Quiescent Current:20mA,Operating Current:50mA.
Working voltage:10~16V (if other ranges can be customized).
Signal voltage:4V~20V (if other ranges can be customized).
life:about100,000times,Working temperature:-40~85'C.

Selection:After power on,long press K12 seconds later into the select function mode,P1-1~P1-4forchoose.
P1-1 operating modes:a signal to trigger relay, time is up,the relay
disconnect users,You can set relay time T,click K2 the hundreddigital
tube starts flashing,then press K3, the hundred digital change;click K2
ten digital tube starts flashing,then press K3,ten digit changes;click K2
bit digital tube starts flashing, then press K3, single-digit change;then
click K2,; digital pipe does not blink,then press the K3, shifting the
decimalpoint,the decimalpointin abitindicates 0-999minutesin ten
represents 0 to 99.9 seconds withou tadecimalpointrepresents 0-999
seconds;goodchoice,bringing the time setting is completed.Short press
K1,enterfunction offine-tuning settings,triggerthedefaultdelayperiod
is invalid, press K1, during the delay trigger active(re-timing),clickon
the K1, during the delay reset (timer turned off,the relay reset) press
again to repeat the default settings for the first time.
P1-2 operating modes:Asignal trigger ,digital countdown begins,X
seconds after,there lay open Y seconds,then close.Users can set the relay
time X,Y;P1-1different time settings similar to the blue lights that set
the relay time,blue light indicates setting relay off time. Short press K1,
enter function offine-tuning the set,the default trigger is invalid during
the delay,pressK1,during the delay trigger active(re-timing),then click
the first repeat default settings.
P1-3 operating modes:Open X seconds,disconnect Yseconds, infinite
loop.Users can set the relay timeX,Y;time setting similar to P1-2.Short
press K1,enter function offine-tuning set,The default function is:set up
an electric circuit the relay first open, press the K1,there lay first
close.Press again to repeat the default functionality.
P1-4 operating modes:a signal to trigger the relay open but do not start
the timer,when the trigger signal disappears,digital count down begins,X
time after,the relayclose; During the delay,again to the signal,digital
count down canceled, stays energized, the signal disappears, restart
count down; (equivalentto release the button to start timing, commonly
usedin power-offdelay).Users canset the relay time X; time setting similar to P1-1.
 
Micro USB 5-30V Delay Relay:
Description:
By adjusting the potentiometer can set the length of time.
MicroUSB 5.0V power supply with an input port, easy to use.
5 ~ 30V wide supply voltage.
External signaltrigger and keytriggerin two ways.
With a relay indicator.
Anti-interference ability, the relay at various interference will not misoperation, suitable for industrial control.

Features:
1. Working voltage: wide voltage 5 ~ 30V, two power supply interface
2. Operating mode:
the initial state, module outputs: normally open (NO) and the common terminal (COM) is disconnected,
normally closed (NC) and the common terminal (COM) connected.
Providing a low pulse signal, or touch trigger key, relay and indicator lights,
the output of the state: normally open (NO) and Common (COM) connected,
normally closed (NC) and the common terminal (COM) is disconnected.
After 0-24 seconds (this time can be adjusted according to your needs) relay off,
back to the state before the trigger.
3. The length of timing adjustment by potentiometer, default 0-24 seconds.
If you need more time, you can replace the larger capacitor (C2) or potentiometer.
Delay time T = 1.1RC. For example: 22uf capacitor and resistor 1M,
then T = 1.1 * 0.000022 * 1000000 = 24.2 seconds.
4. With a relay indicator.
5. The module can control: 10A / 250VAC, 10A / 30VDC load.
6. The relay has a freewheeling protection.
7. Trigger signal input terminal is designed with a pull and filter circuit,
enhanced anti-jamming capability, suitable for industrial control.
Many manufacturers add the optocoupler isolation,
but there is no separation between module’s ground and signal’s ground,
would not achieve the interference effect.
After the test found that only enhance the stability of the signal input port to interference,
regardless of this module is under electromagnetic interference environment,
or in the power-up and power-down moment, the relay will not produce misoperation.
8. Dimensions: 5.4 * 1.9 * 1.8cm (L * W * H)
9. Weight: 16g

Applications
1. Burglar, alarm, building delay switch, sound and light control light switch.
2. Delay powered vehicle equipment, to prevent large currents generated as the car starts burning vehicle equipment.
3. Prevent simultaneous launch multiple devices cause burning appliances or fail to start.
 
Package included:
1Pcs Timer Delay Relay Module(Optional)

We accept Paypal ONLY. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.

We will arrange shipping for you within 24 Hours after payment cleared except the holidays.

We only ship to the confirmed address provided by PayPal. Before you pay, please make sure your address in PayPal matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.

-We ship items to Worldwide. Thank you!

-we will ship out the order in 1-2 business days after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.

* We believe our items are so outstanding. We are convinced you will be happy with your Purchase.

* If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund to you after the returned item arrived at our warehouse.

* Please include your eBay ID and item number with any email requests.

* When you satisfied with our product and services please leave us positive feedback.

* If you have got the package, please confirm "Delivery on time" For us.

* If a problem occurs, contact us immediately with any email request.

* Just contact us using the " Ask the seller a question" link on eBay.


Am 01.04.19 hat der Verkäufer die folgenden Angaben hinzugefügt:

DataCaciques