Thank you for visiting our ClaraMed store with the original collection of our ClaraMed products.

The new model of our LED portable light source provides Ultrabright illumination with sturdy design and low heating of the exterior of the device.

The high CRI index of the LED lamp provides daylight white illumination that gives the natural color of the tissues unlike other LED light source models with bluish white light!

The output illumination of the lamp is about 160000LUX in maximum light mode that gives sufficient light for most medical and surgical procedures.

Featuring two modes of light output gives flexibility, as using the low light mode by slight pressing on the tail switch gives a little lower illumination but much longer battery life.

The included battery is genuine Panasonic NCR18650GA with 3450ma capacity that gives about 3 hours of continuous illumination and the battery stands over 500 cycles of use before starting to lose capacity.

Built in micro USB charging port and charging light indicator allows charging the battery with the supplied USB cable through any USB power outlet and avoids an external battery charger.

(please note that this model allows only charging the device using USB power, but powering the device is only through the battery. For powering the device (turning the light on) using USB please refer to our higher "S1 model" in the following link: https://www.ebay.com/itm/273391303321

The available endoscope connection for this model is for Storz endoscope connection types after removing the small Storz adapter from the endoscope first - please refer to product pictures.

The product variations include:

1- Only connecting the light source directly with endoscopes that have Storz type connection

2- In addition to connecting directly as above, there is an adapter for connecting the the light source with Olympus endoscopes/Light cables

3- In addition to connecting directly, there is an adapter for connecting the light source with Storz compatible light cables

4- Connecting directly to the Storz compatible endoscope +adapter for Olympus endoscopes/Light cables+ adapter for Storz compatible light cables


Technical Data:

Brand: ClaraMed

Color: Black

Material: Aluminum alloy

Number of Emitters: 1

Color BIN: neutral White (daylight)

Color temperature: Approx. 5700K

Working Voltage: 3,2--4.2 V

Life cycle of bulb: Approx.10000 h

Power Supply: 1 x 18650 Lithium Ion battery

Battery brand: Genuine Panasonic NCR18650GA

Actual Lumens: up to 1000 lumens

Run time: about 3 hours (depending on light intensity used)

Charging light indicator: Red when charging - green when fully charged.

Number of Modes: two modes: Full press of  the tail switch turns on the light. Medium press switches between the 2 light modes.

Switch Type: Tail click switch

Package contents:

1-ClaraMed portable LED light source (endoscope not included)

2-Panasonic Lithium ion battery

3-USB cable

Optional: 1-adapter for connecting with Olympus endoscopes (endoscope not included)

2-adapter for connecting with Storz light cables (light cable not included)

3- Adapter for connecting with Storz light cable and another adapter for connecting with Olympus endoscopes or Olympus light cables (endoscopes or light cables are not included)


We ship using DHL express, FedEx, UPS, ARAMEX or EMS and items usually takes 5 to 10 days to be delivered to most countries worldwide.

Note:
1- Please don't forget to remove the Storz connector from Storz endoscopes before attaching the light source (as in the pictures above).

2- This light source supports most of the rigid and flexible endoscopes,, if you're not sure that your endoscope will work or not please contact us before you make the purchase .

3- The color of the shipped Light Source is black.

4- The included battery is shipped with about 40% charge. Please, fully charge the battery before using it.

5- For longer battery life, please do not full charge or fully discharge the battery.

6- If the device is to be stored for a long time, please keep the battery in a partially charged state (about 50%) and do not store it when it is discharged.

7- 
The light source is not autoclavable. To use the device in clean procedures, wrapping the light source with sterile gloves or other sterile covering will be needed.