Features.
1.Detecting voltage range: 0-99.9V, minimum 0.1V adjustable.
2. Charge protection, discharge protection
3. Over-voltage protection, under-voltage protection
4. Fixed-point pulse, stable performance
5. Charge and discharge control, stable performance.
Product Parameter
Voltage: DC12V
Relay contact maximum current: 12A
Detection voltage range: 0-99.9V
Parameter setting instructions
Turn on the power to display the voltage into the standby state, first set two basic parameters, the lower limit voltage V1 and the upper limit voltage V2
1. Press the setup key once to display "F1" flashing.
2. Press the setup key for the second time to display the default V1 value "XX.X" blinking. Press the "plus" button or "minus" control key to adjust the lower limit parameter V1.
3. Press the Setup key for the third time to display the default V2 value "XX.X" blinking, press the "plus" key or "minus" key to adjust the upper limit parameter V2 (at this time, if the V1 participation parameter is greater than V2, it will be displayed). X" blinks, press the "plus" button or "minus" button to adjust the upper limit parameter V2 (if V1 participation parameter is greater than V2, it will be displayed. "ERR" error message, need to change the parameter, be sure to keep V1 less than V2 as normal)
4. Press the Setup button for the fourth time, the parameter will be kept permanently and quit.
5. In standby mode, press the "minus" button for 3 seconds to turn off the display, and press it again for 3 seconds to turn on the display. Designed to reduce power consumption
Function Description
1.F-1 Charging monitoring: when the measured voltage is lower than the voltage V1, the relay will absorb, and the voltage is higher than V2, the relay will disconnect.
2.F-2: Discharge monitoring: when the measured voltage is higher than the voltage V2 relay is activated and the voltage is lower than V1 relay is disconnected.
3. F-3: Out-of-range engagement: when the measured voltage is introduced between V1 and V2, the relay is disconnected.
4. F-4: Intra-range engagement: when the measured voltage is introduced between V1 and V2, the relay is engaged and the other status relays are disengaged.
5. F-5: Fixed-point monitoring: Relay is activated when the measured voltage is higher than V1 and deactivated when it is lower than V1.
6.F-6: Fixed-point self-locking monitoring: when the measured voltage is higher than V1 relay is engaged and remains engaged until manual disconnection.
7.F-7: Fixed-point pulse monitoring: when the measured voltage is equal to V1 every time (floating up and down by 0.1V), the relay outputs an actuating signal.
8.F-8: New function, voltage error correction, range ±5.0V.

Setting method added
In F-1 set up, set up after the other functions of the parameters are used in F-1 set parameters. After pressing the setup key with blinking F-1, then press + or - to adjust the function number, and then press the setup key again after adjusting to a certain function number, then it is OK. After pressing the setup button, the F-1 blinks, then press + or - to adjust the function number, and then press the setup button again after adjusting to a certain function number, then it is OK.
 
Shipping List.
Relay module 1

We accept PayPal only. But we only Accept your Ebay Address,Please Make sure it's 100% right.

Payment must be received in 5 business days of auction closing.

Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.

Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.

We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.

All package need to wait 30 days(US only need 7-10 days),Please take care it.Less than 30 days,we can't take a refund.

If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.

If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.

DataCaciques