Module |
I/O module |
Configuration method |
Via software (Flexi Soft
Designer) Safe EFI-pro System:
Safety Designer |
Safety integrity level |
SIL3 (IEC 61508) |
Category |
Category
4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per
hour) |
4.8 x 10-9 (EN ISO 13849) 1) 0.9 x 10-9 (EN ISO 13849) 2) |
TM (mission time) |
20 years
(EN ISO 13849) |
Flexi Loop-compatible |
✔ |
||||
|
Number of safety inputs |
8 |
Number of test outputs |
2 |
Number of safe outputs |
4 |
Connection type |
Spring terminals |
Protection class |
III (EN 61140) |
||||||||||||||
Voltage supply |
Via FLEXBUS+ |
||||||||||||||
Internal power
consumption |
≤ 2.2 W 1) |
||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|