New in the box Olympus Powerseal PS-0537CJDA Curved Jaw Sealer & Divider 5mm x 37cm

A better workflow meets uncompromising performance.
Your surgical energy device shouldn’t slow you down or interrupt your in-procedure momentum. POWERSEAL™ Sealer/Divider delivers consistently strong vessel sealing throughout the procedure.
Powerseal procedure
POWERSEAL™ Sealer/Divider provides:
  • A true curved, tapered, and double-action Maryland dissector/grasper design.
  • Vessel sealing up to and including 7 mm, including pulmonary vessels, tissue bundles, and lymphatics.3
  • Significantly better seal integrity performance in side-by-side GLP animal lab testing.3
  • Fast sealing, with average seal time less than 2.8 seconds on vessels up to 7mm in diameter.
  • Efficient and consistent sealing performance through greater sealing length and higher jaw pressure.4
  • Equivalent tissue sticking resistance when compared to nano-coated LigaSure Maryland jaw due to POWERSEAL’s proprietary waveform and jaw construction.5
The POWERSEAL™ Sealer & Divider is a bipolar electrosurgical instrument intended for use in laparoscopic/minimally invasive or open surgical procedures where ligation and division of vessels, tissue bundles, and lymphatics is desired.

POWERSEAL instruments can be used on vessels (arteries, veins, pulmonary arteries, pulmonary veins) up to and including 7 mm, lymphatics, and tissue bundles. POWERSEAL instruments are indicated for use in general surgery and such surgical specialties as urologic, colorectal, bariatric, vascular, thoracic, and gynecologic. Procedures may include, but are not limited to, Nissen fundoplication, colectomy, cholecystectomy, adhesiolysis, sleeve gastrectomy, hysterectomy, and oophorectomy.

The POWERSEAL device is intended for single use only, and reusing or re-sterilizing is ill-advised as it could cause excessive wear and degradation of device performance. Changes in material characteristics, such as corrosion, dulled edges, deformation or splitting, may impact the strength of the device. Reusing and/or re-sterilizing can also cause cross-contamination. These risks may potentially impact patient safety. The higher the current flow and the longer the current is applied, the greater the possibility of unintended thermal damage to tissue, especially during use on small appendages.

The POWERSEAL Sealer & Divider has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures. During surgical procedures in which patients exhibit certain types of vascular pathology e.g. atherosclerosis, aneurysmal vessels, apply the seal to unaffected vasculature for best results. As POWERSEAL utilizes Advanced Bipolar Energy, consult first with a qualified professional (e.g. cardiologist) prior to utilizing on patients who have electronic implants such as cardiac pacemakers to avoid possible hazard due to interference with electronic implant.
Buy with confidence, priced to sell.

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

 DISCLAIMER: Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.