Feature:

1. [Double Layer Water Sealing Structure] The double layer water sealing structure, the measured minimum water rate of ≤10L/H, is to allow each pig to drink enough liquid medicine.
2. [Multifunctional] Complete quantitative dosing and mixing functions, continuous proportional injection, accurate proportional tracking adjustment, automatic uniform dilution.
3. [Flexible And Adjustable] The accurate automatic dosing ratio is not affected by the pressure fluctuation of the water , the amount of solution injected is proportional to the amount of water flowing into the pipeline, and the external adjustment is flexible and convenient.
4. [Durable Material] The shell is made of high quality pp material, wear resistant, anti ultraviolet, not easy to age, and the pump body is anti corrosive, ensuring the availability of solutions and long service life.
5. [Direct Installation] Removable and installable consumable parts, in the case of certain wear and tear of small parts, you can also respond and replace in the first time.
6. [Final Dosing Ratio] Dosing device adjustment ratio ⅹ Dilution ratio in the medicine barrel is final dosing ratio. For example, the dosing device is adjusted to 1%, and the dilution in the medicine barrel is 1/15, then the final dosage ratio is equal to 1/1500.


Specification:

Item Type: Fertilizer Injector
Material: Plastic
Product Length: Approx. 38cm / 15in
Product Width: Approx. 16.5cm / 6.5in
Water Inlet And Outlet Thread: G3/4 external thread
Proportion Range: 1:50-1:500 (0.2-2%)
Range: 10L/H-2500L/H
Continuous Operation: >100T
Applicable Scene: Dilution proportioning pump with dosing equipment in farms, car wash water wax diluting proportioning pump, fertilizer applicator ejector for greenhouse
Remark: Accessories are random in color
Application: Agricultural irrigation, equipment maintenance, gardening flowers, animal husbandry, environmental protection water treatment, industrial disinfection, car wash foam, food processing, industrial hygiene, printing and other industries that require constant ratio dilution
Weight: Approx. 1587g-1642g / 56oz-57.9oz
Application of Dosing Device:
1. The variety and dosage of drugs can be changed at any time
2. Convenient and quick to add medicine in emergency
3. The customer prepares the detergent by himself, adds the detergent in the cleaning channel, and cleaning the drinking water and livestock and poultry water pipelines
4. Solve the problem of precipitation and pollution in the water storage tank
5. Automatic spray system, used to replace the water tank on the sterilizer
6. It can be used at any time for sanitation and cleaning water pipes and sinks, water network cleaning, odor treatment, equipment, maintenance, conveyor belt cleaning, livestock and poultry drinking water treatment, acidification treatment
Maintenance method of dosing device:
Due to the influence of objective conditions such as the impurities in the breeding water and the crystallization of the liquid, it is recommended to clean the dosing device and filter every month, as follows
1. Filter cleaning:
Rotate the brush at the bottom of the filter by hand every month. After opening the backwash valve, the water will wash off the impurities
It is recommended to use a wrench to open the filter cover every 6 months and rinse the filter with a brush
2. Dosing device cleaning:
After each addition of the liquid medicine, add about 5L of clean water to the medicine bucket, wait for the dosing device to absorb the clean water, and then close it (the dosing device will have a certain self cleaning effect)
Unscrew the suction nozzle at the bottom of the dosing device every month to deal with the problem of water return caused by impurity crystallization precipitation
Problem Description:
1. The liquid medicine in the pipette is sucked up and returned to the medicine bucket again
2. The liquid medicine in the pipette is sucked up and returned to the medicine barrel again with air in it
3. The water in the dosing device flows back to the medicine bucket through the suction pipe
Solution:
1. Rotate the suction nozzle clockwise and unscrew it. Wash the internal sediment and other impurities with water. Pay attention to the grooves gasket in the suction nozzle. After cleaning, place the grooves upward and center. Reinstall the problem to solve
2. Check whether the suction hose is aging, cracked or damaged. If it is damaged, please replace it
3. The grooves gasket is aging and replaced (there is a rectangular ring spare part in the spare parts package)
Note: Use an opener wrench every 6 months to disassemble the dosing device cover; after cleaning, you can apply mortar wood on the sealing ring to improve the lubricity of the piston
Problem Description:
1. When the dosing device is working, you can hear clicks and clicks, but the suction tube does not suck medicine into the dosing device or the amount of medicine sucked is very small
2. There will be a squeaking noise when the dosing device is working
Solution:
1. Use a lid opener to open the large lid of the dosing device
2. Take out the piston and check the rectangular ring on the pumping rod to see if it is severely worn or broken. If so, please replace it with a new rectangular ring
3. Check if there are impurities or grit at the bottom of the rectangular ring, please clean it up.
4. Check whether there is scale or medicine slag around the rectangular circle. If there is, please clean it with a cotton swab
5. If abnormal noise occurs when the dosing device is working, please apply grease to the rectangular ring to solve it
(The grease needs to be purchased separately by the customer)


Package List:

1 x Chemical Fertilizer Injector with Filter Transparent Tube

1 x English Manual

2 x White Accessory Circle

1 x Wrench

3 x Black Washer

2 x Metal Accessories


Note:

Precautions for the installation of the dosing device:
1.When installing the filter and the dosing device, please pay attention to the installation of the filter in the front and the dosing device in the back.
2. Both the filter and the dosing device have direction arrows, please keep the installation in the same direction as the water .
Precautions for the use of the dosing device adjustment method:
1. Please refer to the instructions to adjust the dilution ratio of the dosing device and the barrel.
2. Please do not adjust the scale above 2% or below 0.2%, so as not to affect the accuracy.
  



 

1. Our listing price includes the value of goods,packaging cost,and export taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3. The duties are buyers' responsibility.Please check with your country's customs office determine what these additional costs will be prior to your purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.

 

1. Any questions, pls. contact us via ebay message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.

2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "5 " in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. 

https://image-us.chengykj.com/upload/third_resource/image/feedback.jpg


We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders. 

https://image-us.chengykj.com/upload/third_resource/image/shipc73.jpg

DataCaciques