USB One Channel Relay

for MACH3 CNC software

 

KMtronic USB Relay

 



KMtronic LTD


- Fully assembled and tested.
- Powered from USB
- For 12V/24V DC 15A or 120V/220V AC at 10A max


Relay have Normally Open (NO) and
Normally Closed (NC) Contacts capable of switching max:
- 12VDC/15A
- 24VDC/15A
- 125VAC/15A
- 250VAC/10A


100 mm / 58 mm / 24 mm


Fully powered from USB


FTDI USB to Serial converter: FT232RL
Windows(all versions), Linux, Mac OS 8, Mac OS 9, Mac OS X,
Arduino, Raspberry PI ...


8 Data, 1 Stop, No Parity
Baud rate : 9600


OFF command : FF 01 00 (HEX) or 255 1 0 (DEC)
ON command : FF 01 01 (HEX) or 255 1 1 (DEC)
Status request : FF 01 03 (HEX) or 255 1 3 (DEC)



All in tree steps:

1. Connect USB relay to PC and install the drivers.



2. Download KMtronic.DLL and place it in your Mach3 install folder (usually C:\Mach3)



3. Add to your macro or button script ON or OFF command

Command's:

a = Relay(5,1,"ON")  - where "5" is USB COM port, "1" is relay number, "ON" is command, which turns ON the relay number 1 connected to COM5
a = Relay(5,1,"OFF")  - where "5" is USB COM port, "1" is relay number, "OFF" is command, which turns OFF the  relay number 1 connected to COM5

Note- every script where you use commands has to start with this declaration:
Declare Function Relay Lib "KMSerial.dll" (ByVal comPort As Integer,ByVal numberRelay As Integer,ByVal command As String) As Boolean

 

 

htm1