1 Stück / 1 piece UC2840N
PROGRAMMABLE OFF-LINE PWM CONTROLLER IC

Vcc 32V | -25°C to +85°C | DIP-18 package

UC2840N    UC2840N   UC2840N

Although containing most of the features required by all types of switching power supply controllers. The UC1840 family has been optimized for highly-efficient boot-strapped prirnaryside operation in foreward or flyback power converters. Two important features for this mode are a starting circuit which requires little current from the primary input voltage and feed-forward control lor constant volt-second operation over a wide input voltage range.
In addition to startup and normal regulating PWM functions,these devices ofter built-inprotection from over-voltage, under-voltage, and over-current fault conditions. This monitoring circuitry contains the added features that any fault will initiate a complete shutdown with provisions for either latch off or automatic restart. In the latch off mode, the controller may be started and stopped with external pulsed or steady-state commands.
Other performance features ot these devices include a 1% accurate reference, provision for slow-turn-on and duty-cycle limiting, and highspeed pulse-by-pulse current limiting in addition to current fault shutdown.
The UC2840‘s PWM output stage includes a latch to insure only a single pulse per period and is designed to optimize the turn off of an external switching device by conducting during the "OFF" time with a capability for both high peak current and low saturation voltage. These devices are available in an 18-pin dual-in-line plastic or ceramic package.
The UC2840 and UC3840 are designed for operation from -25'C to +85 C and 0 C to +70 C. respectively.
  • ALL CONTROL, DRIVING, MONITORING AND PROTECTION FUNCTIONS INCLUDED
  • LOW-CURRENT, OFF-LINE START CIRCUIT
  • FEED-FORWARD LINE REGULATION OVER 4 TO 1 INPUT RANGE
  • PWM LATCH FOR SINGLE PULSE PER PERIOD
  • PULSE-BY-PULSE CURRENT LIMITING PLUS SHUTDOWN FOR OVER-CURRENT FAULT
  • NO START-UP OR SHUTDOWN TRANSIENTS
  • SLOW TURN-ON AND MAXIMUM DUTY-CYCLE CLAMP
  • SHUTDOWN UPON OVER-OR UNDERVOLTAGE SENSING
  • LATCH OFF OR CONTINUOUS RETRY AFTER FAULT
  • REMOTE, PULSE-COMMANDABLE START/STOP
  • PWM OUTPUT SWITCH USABLE TO 1A PEAK CURRENT
  • 1% REFERENCE ACCURACY
  • 500 kHz OPERATION

NEW OLD STOCK (NOS)
NOT PULLED - NOT USED - NOT REFURBISHED - NOT SOLDERED - NOT RE-MARKED - NOT FAKED EXCLUSIVELY
AUSSCHLIESSLICH NUR ALTE NEUE WARE (NOS) aus Altlagerbestand
entnommen aus der original Verpackung (siehe Foto)

Bitte fragen sie uns an, falls sie größere Stückzahlen benötigen oder geben Sie uns hierzu Ihren Preisvorschlag