New Feature:


LED Back light 

MIN/MAX Mode

Larger screen: 1.5 times of F17B's 

Faster response time than F17B 



General Specifications: 


Maximum Voltage between any Terminal and Earth Ground: 1000 V


Display(LCD)......................................................4000 counts,updates 3/sec

Battery Type.......................................................2 AA,NEDA 15A, IEC LR6

Battery life...........................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)


Temperatuer

Operating............................................................0 deg to 40 deg

Storage................................................................-30 deg to 60 deg

Relative Humidity

Operating Humidity...........................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg

Operating Humidity,40MC Range..................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg

Altitude

Operating............................................................2000m

Storage................................................................12.000m

Temperature Coefficient..................................0.1×(specified accuracy)/deg(<18deg or > 28deg)

Fuse protection for current inputs................440 mA,1000 V Fast Fuse, Fluck specified part only.

                                                                                11A,1000v Fast Fuse, Fluke specified part only.

Size(H×W×L).......................................................183×91×49.5(mm)

Weight...................................................................455g

IP Rating...............................................................IP 40

Safety....................................................................IEC 61010-1, IEC61010-2-030 600V CAT3,1000V CAT2,Pollution Degree 2

Electromagnetic Environment........................IEC 61326-1:Portable

Electromagnetic Compatibility........................Applies to use in Korea only

 Class A Equipment(Industrial Broadcasting and Communication Equipment)



ACCURACY SPECIFICATION


Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy


specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])


Package included :


1. A Pair of Original Test leads

2. Thermocouple

3. True FLUKE F17B+ meter

5. User Manual

( Battery not included)


Weight: 850g



Function

Range

Resolution

Accuracy

Model 15B+

Model 17B+

AC Volts (40 to 500 Hz)400.0 mV 10.1 mV

3.0 % + 3

3.0 % + 3

4.000 V 40.00 V 400.0 V 1000 V

0.001 V 0.01 V 0.1 V 1 V

1.0 % + 3

1.0 % + 3
DC Millivolts M400.0 mV0.1 mV

1.0 % + 10

1.0 % + 10
DC Volts V4.000 V 40.00 V 400.0 V 1000 V0.001 V 0.01 V 0.1 V 1 V

0.5 % + 3

0.5 % + 3
Diode Test2.000 V0.001 V10 %
Temperature50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C0.1 °CNA2 % + 1 °C ± 2 °C 9 % + 2 °C
Resistance (Ohms)400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 30.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3
Capacitance 4 c50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF 1000.0µF0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1µF2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 52 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5
Frequency Hz (10 Hz -100 kHz)50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHzNA0.1 % + 3
Duty Cycle0.1 % to 99.9 %0.1%NA

1% typical

 





Function

Range

Resolution

Accuracy

Model 15B+

Model 17B+

AC Current (40 to 200 Hz)400.0 µA0.1 µA

1.5 % + 3

1.5 % + 3

 4000 µA1 µA  
AC Current (40 to 200 Hz)40.00 mA0.01 mA

1.5 % + 3

1.5 % + 3

 400.0 mA0.1 mA  
AC Current (40 to 200 Hz)4.000 A 10.00 A0.001 A 0.01 A

1.5 % + 3

1.5 % + 3

DC Current400.0 µA0.1 µA

1.5 % + 3

1.5 % + 3

 4000 µA1 µA  
DC Current40.00 mA0.01 mA

1.5 % + 3

1.5 % + 3


400.0 mA0.1 mA






DC Current4.000 A0.001 A

1.5 % + 3

1.5 % + 3

 10.00 A0.01 A  






Function

Overload Protection

Input Impedance (Nominal)

Common Mode Rejection Ratio

Normal Mode Rejection

AC Volts V1000 V

>10 MΩ <100 pF

>60 dB at dc, 50 or 60 Hz_
DC Volts V1000 V

>10 MΩ <100 pF

>100 dB at dc, 50 or 60 Hz>60 dB at 50 or 60 Hz