Features
1.
Based on the new class B of international EN13060, have 3 pulsating
vacuum. Vacuum up to -0.9Bar (-0.09Mpa). Suitable to sterilizing wrap,
unwrap, solid, porous, hollow device.
2.
Use imported & advanced 16-bit microprocessor, easy to operate.
Most suitable for the Dept of Stomatology, Ophthalmology, Surgery and
Lab.
3. With BD test and vacuum test procedures.
4. The jet type of steam generator, ensure the efficient sterilizing.
5. With alarm system for waste water tank, avoid the waste water to enter into the sterilizing circulation, make the
sterilizing completely.
6. Precise digital display and advanced self-test system ensure you get the working data freely.
7. Double lock door for safety during operating.
8. Optional inbuilt mini-printer or USB connector to record the process of sterilizing.
Specifications
Rated Voltage: 220V±22V, 50Hz±1Hz, 110V±11V, 60Hz±1Hz
Rated Power: 1800W
Sterilizing (Pressure/temp.): 0.9-1.3bar/120oC, 2.0-2.3bar/120oC (Both of above are Under Standard Atmospheric pressure)
Fuse-Melting pipe: T15A / T30A
Capacity: 16Liters
Water Consumption volume per recycling round: 0.3L
Working programs: 4
Operating Temp: 0-40oC
Inside dimensions: 240mmX360mm
Outside dimensions(16L):445*550*395mm
package dimensions:670*550*500mm
Net Weight: 45kg
Gross weight: 47kg
SKU: MT-D-16L(D)-220-B-UK
Please Note
1. The autoclave must be placed on the horizontal working base.
2. Must use the distilled water for the purpose of lasting the working life.
3. There shall be no clog to the air cooling window on the outer surface.
4.
The object apparatus to be sterilized shall be placed on the device
plate with enough clearance retained in favor of the air circulation
inside the sterilizing room.
5.
Empty the water inside the cooling water collecting tank frequently.
Usually, the cooling water collecting tank shall be emptied once the
water storing tank emptied.
6. Must revolve the door handle to the teminal side while working.
7. Don't open the door of autoclave when seeing the "0" displayed on the pressure indicator.
8. Not be too closed to the door of the autoclave in case of scald when open the door.
9.
Shut off the power before discharging/installing the sealing ring, and
the work shall be carried out after further sufficient cooling in case
of scald.
10. Don't drag or drop the autoclave during relocation period of the autoclave.
11. The protecting ground shall be reliable.
12. Equipment must be used away from teh magnetic field.
13. Equipment life end, dealing with to local environmental protection laws and regulations.